diff options
author | Frank Brockners <fbrockne@cisco.com> | 2017-03-05 07:45:56 -0800 |
---|---|---|
committer | Frank Brockners <fbrockne@cisco.com> | 2017-03-06 01:28:52 -0800 |
commit | bb0f2b593f1c481e202fae168e85202b370c948a (patch) | |
tree | 7f9862e4f32ca1cc9a1c7882e5392d3ce8b1cd81 /docs/scenarios/os-odl_l2-fdio-noha/scenario.description.rst | |
parent | 8f21ca2d5951be14464b3a99b9e792b3bd7a63b0 (diff) |
Updated docs for odl_l2-noha for Danube
Updated scenario documentation for os-odl_l2-fdio-noha to reflect
changes in the Danube release.
Change-Id: Id9d2a5cd981c3cfaea384c5b1cb1fb9cfe736f83
Signed-off-by: Frank Brockners <fbrockne@cisco.com>
Diffstat (limited to 'docs/scenarios/os-odl_l2-fdio-noha/scenario.description.rst')
-rwxr-xr-x | docs/scenarios/os-odl_l2-fdio-noha/scenario.description.rst | 196 |
1 files changed, 90 insertions, 106 deletions
diff --git a/docs/scenarios/os-odl_l2-fdio-noha/scenario.description.rst b/docs/scenarios/os-odl_l2-fdio-noha/scenario.description.rst index 076e37c..b392070 100755 --- a/docs/scenarios/os-odl_l2-fdio-noha/scenario.description.rst +++ b/docs/scenarios/os-odl_l2-fdio-noha/scenario.description.rst @@ -39,8 +39,8 @@ NFV infrastructure are reflect different business In order to meet the desired qualities of an NFV infrastructure, the -following components were chosen for the "Openstack - OpenDaylight - - FD.io/VPP" scenario: +following components were chosen for the "Openstack - OpenDaylight - FD.io" +scenario: * FD.io Vector Packet Processor (VPP) - a highly scalable, high performance, extensible virtual forwarder * OpenDaylight Controller - an extensible controller platform which @@ -50,7 +50,7 @@ following components were chosen for the "Openstack - OpenDaylight component, and can be clustered to achieve a highly available deployment. -The "Openstack - OpenDaylight - FD.io/VPP" scenario provides the capability to +The "Openstack - OpenDaylight - FD.io" scenario provides the capability to realize a set of use-cases relevant to the deployment of NFV nodes instantiated by means of an Openstack orchestration system on FD.io/VPP enabled compute nodes. The role of the Opendaylight network controller in this integration is @@ -76,8 +76,8 @@ servers: .. image:: FDS-odl_l2-overview.png -Tenant networking leverages FD.io/VPP. Open VSwitch (OVS) is used for all other -connectivity, in particular the connectivity to public networking / the +Tenant networking leverages FD.io/VPP. Open VSwitch (OVS) is used for all +other connectivity, in particular the connectivity to public networking / the Internet (i.e. br-ext) is performed via OVS as in any standard OpenStack deployment. The OpenDaylight network controller is used to setup and manage layer 2 networking for the scenario. Tenant networking can either leverage @@ -113,94 +113,45 @@ The apex-os-odl_l2-fdio-noha scenario combines components from three key open source projects: OpenStack, OpenDaylight, and Fast Data (FD.io). The key components that realize the apex-os-odl_l2-fdio-noha scenario and which differ from a regular, OVS-based scenario, are the OpenStack ML2 OpenDaylight plugin, -OpenDaylight Neutron Northbound, OpenDaylight Group Based Policy, OpenDaylight -Virtual Bridge Domain Manager, FD.io Honeycomb management agent and FD.io -Vector Packet Processor (VPP). +OpenDaylight Neutron Northbound, OpenDaylight (ODL) Group Based Policy (GBP), +OpenDaylight Virtual Bridge Domain Manager (VBD), FD.io Honeycomb management +agent and FD.io Vector Packet Processor (VPP). Here's a more detailed list of the individual software components involved: -**Openstack Neutron ML2 ODL Plugin**: Handles Neutron data base synchronization -and interaction with the southbound Openstack controller using HTTP. - -**OpenDaylight Neutron Nothbound & Neutron MD-SAL Entry Store**: Presents a -Neutron (v2) extended HTTP API servlet for interaction with Openstack Neutron. -It validates and stores the received Neutron data in the MD-SAL data store -against the Neutron yang model driven. - -**OpenDaylight Neutron Mapper**: The Neutron Mapper listens to Neutron data -change events and is responsible for using Neutron data in creating Group Based -Policy Data objects, e.g. GBP End-Points, Flood-Domains. A GBP End Point -represents a specific NFV/VM port and its identity as derived from a Neutron -Port. The mapped data is stored using the GBP End Point yang model and an -association between the GBP End-Point and its Neutron object is maintained in -the Neutron-GBP map. - -**OpenDaylight Group Based Policy (GBP) Entities store**: Stores for the GBP -data artifacts against the GBP YANG schemas. - -**Neutron Group Based Policy Map store**: Stores the bi-lateral relation -between an End-Point and its corresponding Neutron object. Neutron-GBP map; -keyed by Neutron object type, port, and Neutron UUID, gives the GBP End-Point, -Flood domain respectively. GBP-Neutron map keyed by GBP object type, end-point. - -**Neutron VPP Renderer Mapper**: The Neutron VPP Renderer Mapper listens to -Neutron Store data change events, as well as being able to access directly the -store, and is responsible for converting Neutron data specifically required to -render a VPP node configuration with a given End Point, e.g. the virtual host -interface name assigned to a vhostuser socket.. The mapped data is stored in -the VPP info data store. - -**VPP Info Store**: Stores VPP specific information regarding End-Points, Flood -domains with VLAN, etc. - -**GBP Renderer Manager**: The GBP Renderer Manager is the central point for -dispatching of data to specific device renderers. It uses the information -derived from the GBP end-point and its topology entries to dispatch the task of -configuration to a specific device renderer by writing a renderer policy -configuration into the registered renderer's policy store. The renderer manager -also monitors, by being a data change listener on the VPP Renderer Policy -States, for any errors in the application of a rendered configuration. - -**Renderer Policy Config Store**: The store's schema serves as the API between -the Renderer Manager and specific Renderers like the VPP Renderer. The store -uses a a YANG modeled schema to represent all end-point and associated GBP -policy data. - -**Topology Entries Store**: The yang model based MD-SAL topology store serves -two fundamental roles: 1. It maintains a topological representation of the GBP -End Points, in the context of customer networks. 2. It maintains an association -of each (VPP) compute node's physical interfaces to their neutron provider -network (e.g. The association between an ethernet interface and a Neutron -provider network). - -**VPP Renderer**: The VPP Renderer registers an instance for VPP nodes with the -Renderer Manager by means of inserting operational data into the Renderer -Policy config store. It acts as a listener on the Renderer Policy consumes via -the GBP Policy API data + the specific VPP End Point data, to drive the -configuration of VPP devices using NETCONF Services. -More specifically, the renderer generates: - - * vhost user port configuration that corresponds to the VM port configuration - * VPP bridge instances corresponding to the GBP flood domain - * port or traffic filtering configuration, in accordance with the GBP policy. - -The VPP Renderer also interacts with the Virtual Bridge Domain Service, by -means of the VBD store, in order to establish connectivity between VPP nodes in -a bridge domain. For this it uses the VPP device name, and the flood domain -data derived from the VPP Info and End-Point data respectively. For the -executed configuration operations it updates state in the Renderer policy state -store. - -**Virtual Bridge Domain (VBD) Store and Manager**: The virtual bridge domain -manager is responsible for configuring the VxLAN overlay tunnel infrastructure -to arrive at a desired bridged topology between multiple (VPP) compute nodes. -VDB configures VXLAN tunnels always into a full-mesh with split-horizon group -forwarding applied on any domain facing tunnel interface (i.e. forwarding -behavior will be that used for VPLS). - -**NETCONF Mount Point Service & Connector**: Collectively referred to as -Netconf Services, provide the NETCONF interface for accessing VPP configuration -and operational data stores that are represented as NETCONF mounts. +**Openstack Neutron ML2 OpenDaylight Plugin**: Handles Neutron data base +synchronization and interaction with the southbound controller using a REST +interface. + +**ODL GBP Neutron Mapper**: Maps neutron elements like networks, subnets, +security groups, etc. to GBP entities: Creates policy and configuration for +tenants (endpoints, resolved policies, forwarding rules). + +**ODL GBP Neutron VPP Mapper**: Maps Neutron ports to VPP endpoints in GBP. + +**ODL GBP Location Manager**: Provides real location for endpoints (i.e. Which +physical node an endpoint is connected to). + +**GBP Renderer Manager**: Creates configuration for Renderers (like e.g. +VPP-Renderer or OVS-Renderer). The GBP Renderer Manager is the central point +for dispatching of data to specific device renderers. It uses the information +derived from the GBP end-point and its topology entries to dispatch the task +of configuration to a specific device renderer by writing a renderer policy +configuration into the registered renderer's policy store. The renderer +manager also monitors, by being a data change listener on the VPP Renderer +Policy States, for any errors in the application of a rendered configuration. + +**GBP VPP Renderer Interface Manager**: Listens to VPP endpoints in the +Config DataStore and configures associated interfaces on VPP via HoneyComb. + +**GBP VPP Renderer Renderer Policy Manager**: Manages the creation of +bridge domains using VBD and assigns interfaces to bridge domains. + +**Virtual Bridge Domain Manager (VBD)**: Creates bridge domains (i.e. in case +of VXLAN creates full mesh of VXLAN tunnels, configures split horizon on +tunnel endpoints etc.). VDB configures VXLAN tunnels always into a full-mesh +with split-horizon group forwarding applied on any domain facing tunnel +interface (i.e. forwarding behavior will be that used for VPLS). **Virtual Packet Processor (VPP) and Honeycomb server**: The VPP is the accelerated data plane forwarding engine relying on vhost user interfaces @@ -208,20 +159,45 @@ towards Virtual Machines created by the Nova Agent. The Honeycomb NETCONF configuration server is responsible for driving the configuration of the VPP, and collecting the operational data. -**Rendered Policy State Store**: Stores data regarding the execution of -operations performed by a given renderer. - **Nova Agent**: The Nova Agent, a sub-component of the overall Openstack architecture, is responsible for interacting with the compute node's host Libvirt API to drive the life-cycle of Virtual Machines. It, along with the compute node software, are assumed to be capable of supporting vhost user interfaces. -The picture below show a basic end to end call flow for creating a Neutron -vhostuser port on VPP using a GBP renderer. It showcases how the different -component described above interact. +The picture below shows the key components. + +.. image:: FDS-basic-components.jpg + +To provide a better understanding how the above mentioned components interact +with each other, the following diagram shows how the example of creating a +vhost-user port on VPP through Openstack Neutron: + +To create or update a port, Neutron will send a request to ODL Neutron +Northbound which contains the UUID, along with the host-id as "vpp" and +vif-type as "vhost-user". The GBP Neutron mapper turns the "Neutron speak" of +"ports" into the generic connectivity model that GroupBasedPolicy uses. +Neutron "ports" become generic "GBP Endpoints" which can be consumed by the +GBP Renderer Manager. The GBP Renderer Manager resolves the policy for the +endpoint, i.e. it determines which communication relationships apply to the +specific endpoint, and hands the resolution to a device specific renderer, +which is the VPP renderer in the given case here. VPP renderer turns the +generic policy into VPP specific configuration. Note that in case the policy +would need to be applied to a different device, e.g. an OpenVSwitch (OVS), +then an "OVS Renderer" would be used. VPP Renderer and the topology manager +("Virtual Bridge Domain" manager - i.e. VBD) cooperate to create the actual +network configuration. VPP Renderer configures the interfaces to the virtual +machines (VM), i.e. the vhost-user interface in the given case here and +attaches them to a bridge domain on VPP. VBD handles the setup of connectivity +between bridge domains on individual VPPs, i.e. it maintains the VXLAN tunnels +in the given case here. Both VPP Renderer as well as VBD communicate with the +device through Netconf/YANG. All compute and control nodes run an instance of +VPP and the VPP-configuration agent "Honeycomb". Honeycomb serves as a +Netconf/YANG server, receives the configuration commands from VBD and VPP +Renderer and drives VPP configuration using VPP's local Java APIs. + +.. image:: FDS-simple-callflow.png -.. image:: FDS-basic-callflow.jpg Scenario Configuration ====================== @@ -231,10 +207,10 @@ settings in the APEX configuration files. Those are typically found in /etc/opnfv-apex. File "deploy_settings.yaml" choose opendaylight as controller with version -"boron" and enable vpp as forwarder. "hugepages" need to set to a -sufficiently large value for VPP to work. The default value for VPP is -1024, but this only allows for a few VMs to be started. If feasible, -choose a significantly larger number on the compute nodes:: +"carbon" and enable vpp as forwarder. "hugepages" need to set to a +sufficiently large value for VPP to work. The default value for VPP is 1024, +but this only allows for a few VMs to be started. If feasible, choose a +significantly larger number on the compute nodes:: global_params: ha_enabled: false @@ -242,7 +218,7 @@ choose a significantly larger number on the compute nodes:: deploy_options: sdn_controller: opendaylight sdn_l3: false - odl_version: boron + odl_version: carbon tacker: true congress: true sfc: false @@ -256,14 +232,22 @@ choose a significantly larger number on the compute nodes:: hugepagesz: 2M intel_iommu: 'on' iommu: pt + isolcpus: 1,2 + vpp: + main-core: 1 + corelist-workers: 2 + uio-driver: uio_pci_generic Compute: - nova: - libvirtpin: 1 kernel: hugepagesz: 2M hugepages: 2048 intel_iommu: 'on' iommu: pt + isolcpus: 1,2 + vpp: + main-core: 1 + corelist-workers: 2 + uio-driver: uio_pci_generic Validated deployment environments @@ -283,7 +267,7 @@ on the following sets of hardware: Limitations, Issues and Workarounds =================================== -There are no known issues. +For specific information on limitations and issues, please refer to the APEX installer release notes. References ========== @@ -293,5 +277,5 @@ References * Fast Data (FD.io): https://fd.io/ * FD.io Vector Packet Processor (VPP): https://wiki.fd.io/view/VPP * OpenDaylight Controller: https://www.opendaylight.org/ - * OPNFV Colorado release - more information: http://www.opnfv.org/colorado + * OPNFV Carbon release - more information: http://www.opnfv.org/carbon |