diff options
author | Carlos Goncalves <carlos.goncalves@neclab.eu> | 2015-09-01 14:30:28 +0000 |
---|---|---|
committer | Gerrit Code Review <gerrit@172.30.200.206> | 2015-09-01 14:30:28 +0000 |
commit | 853ed1577c3e87318b8b8f2adb4210f5a5d7459f (patch) | |
tree | 94a663257969bd3f7dd1397db0d958a2af86f5c1 /requirements | |
parent | 10ea87c6c9e8121f33976d01d2e96b9f74211796 (diff) | |
parent | 83211c137c857634e4b1e51227529d8af9b89f83 (diff) |
Merge "Move fault table to the Annex"
Diffstat (limited to 'requirements')
-rw-r--r-- | requirements/03-architecture.rst | 61 | ||||
-rw-r--r-- | requirements/04-gaps.rst | 5 | ||||
-rw-r--r-- | requirements/07-annex.rst | 64 | ||||
-rw-r--r-- | requirements/index.rst | 1 |
4 files changed, 68 insertions, 63 deletions
diff --git a/requirements/03-architecture.rst b/requirements/03-architecture.rst index 58fa7968..14055485 100644 --- a/requirements/03-architecture.rst +++ b/requirements/03-architecture.rst @@ -284,65 +284,6 @@ It consists of the following steps: 8. The Administrator is coordinating and executing the maintenance operation/work on the NFVI. Note: this step is out of scope of Doctor. -Faults ------- - -Faults in the listed elements need to be immediately notified to the Consumer in -order to perform an immediate action like live migration or switch to a hot -standby entity. In addition, the Administrator of the host should trigger a -maintenance action to, e.g., reboot the server or replace a defective hardware -element. - -Faults can be of different severity, i.e., critical, warning, or -info. Critical faults require immediate action as a severe degradation of the -system has happened or is expected. Warnings indicate that the system -performance is going down: related actions include closer (e.g. more frequent) -monitoring of that part of the system or preparation for a cold migration to a -backup VM. Info messages do not require any action. We also consider a type -"maintenance", which is no real fault, but may trigger maintenance actions -like a re-boot of the server or replacement of a faulty, but redundant HW. - -Faults can be gathered by, e.g., enabling SNMP and installing some open source -tools to catch and poll SNMP. When using for example Zabbix one can also put an -agent running on the hosts to catch any other fault. In any case of failure, the -Administrator should be notified. Table 1 provides a list of high level faults -that are considered within the scope of the Doctor project requiring immediate -action by the Consumer. - - -+------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| Service | Fault | Severity | How to detect? | Comment | Action to recover | -+------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| Compute Hardware | Processor/CPU failure, CPU condition not ok | Critical | Zabbix | | Switch to hot standby | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | Memory failure/Memory condition not ok | Critical | Zabbix (IPMI) | | Switch to hot standby | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | Network card failure, e.g. network adapter connectivity lost | Critical | Zabbix/Ceilometer | | Switch to hot standby | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | Disk crash | Info | RAID monitoring | Network storage is very redundant (e.g. RAID system) and can guarantee high availability | Inform OAM | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | Storage controller | Critical | Zabbix (IPMI) | | Live migration if storage is still accessible; otherwise hot standby | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | PDU/power failure, power off, server reset | Critical | Zabbix/Ceilometer | | Switch to hot standby | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | Power degradation, power redundancy lost, power threshold exceeded | Warning | SNMP | | Live migration | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | Chassis problem (.e.g fan degraded/failed, chassis power degraded), CPU fan problem, temperature/thermal condition not ok | Warning | SNMP | | Live migration | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | Mainboard failure | Critical | Zabbix (IPMI) | | Switch to hot standby | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | OS crash (e.g. kernel panic) | Critical | Zabbix | | Switch to hot standby | -+------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| Hypervisor | System has restarted | Critical | Zabbix | | Switch to hot standby | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | Hypervisor failure | Warning/Critical | Zabbix/Ceilometer | | Evacuation/switch to hot standby | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | Zabbix/Ceilometer is unreachable | Warning | ? | | Live migration | -+------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| Network | SDN/OpenFlow switch, controller degraded/failed | Critical | ? | | Switch to hot standby or reconfigure virtual network topology | -+ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ -| | Hardware failure of physical switch/router | Warning | SNMP | Redundancy of physical infrastructure is reduced or no longer available | Live migration if possible, otherwise evacuation | -+------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ - .. vim: set tabstop=4 expandtab textwidth=80: + diff --git a/requirements/04-gaps.rst b/requirements/04-gaps.rst index a5e37fd4..67ef86c4 100644 --- a/requirements/04-gaps.rst +++ b/requirements/04-gaps.rst @@ -176,7 +176,7 @@ ___________________________________ handle faults on them by Ceilometer. - OpenStack may have monitoring functionality in itself and can be integrated with third party monitoring tools. - - OpenStack need to be able to detect the faults listed in Section 3.5. + - OpenStack need to be able to detect the faults listed in the Annex. + As-is @@ -188,8 +188,7 @@ ___________________________________ + Gap - - Ceilometer is not able to detect and handle all faults listed in Section - 3.5. + - Ceilometer is not able to detect and handle all faults listed in the Annex. * Related blueprints / workarounds diff --git a/requirements/07-annex.rst b/requirements/07-annex.rst new file mode 100644 index 00000000..dbe41bd1 --- /dev/null +++ b/requirements/07-annex.rst @@ -0,0 +1,64 @@ +Annex: NFVI Faults +================================================= + +Faults in the listed elements need to be immediately notified to the Consumer in +order to perform an immediate action like live migration or switch to a hot +standby entity. In addition, the Administrator of the host should trigger a +maintenance action to, e.g., reboot the server or replace a defective hardware +element. + +Faults can be of different severity, i.e., critical, warning, or +info. Critical faults require immediate action as a severe degradation of the +system has happened or is expected. Warnings indicate that the system +performance is going down: related actions include closer (e.g. more frequent) +monitoring of that part of the system or preparation for a cold migration to a +backup VM. Info messages do not require any action. We also consider a type +"maintenance", which is no real fault, but may trigger maintenance actions +like a re-boot of the server or replacement of a faulty, but redundant HW. + +Faults can be gathered by, e.g., enabling SNMP and installing some open source +tools to catch and poll SNMP. When using for example Zabbix one can also put an +agent running on the hosts to catch any other fault. In any case of failure, the +Administrator should be notified. The following table provides a list of high +level faults that are considered within the scope of the Doctor project +requiring immediate action by the Consumer. + + + ++------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| Service | Fault | Severity | How to detect? | Comment | Action to recover | ++------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| Compute Hardware | Processor/CPU failure, CPU condition not ok | Critical | Zabbix | | Switch to hot standby | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | Memory failure/Memory condition not ok | Critical | Zabbix (IPMI) | | Switch to hot standby | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | Network card failure, e.g. network adapter connectivity lost | Critical | Zabbix/Ceilometer | | Switch to hot standby | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | Disk crash | Info | RAID monitoring | Network storage is very redundant (e.g. RAID system) and can guarantee high availability | Inform OAM | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | Storage controller | Critical | Zabbix (IPMI) | | Live migration if storage is still accessible; otherwise hot standby | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | PDU/power failure, power off, server reset | Critical | Zabbix/Ceilometer | | Switch to hot standby | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | Power degradation, power redundancy lost, power threshold exceeded | Warning | SNMP | | Live migration | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | Chassis problem (.e.g fan degraded/failed, chassis power degraded), CPU fan problem, temperature/thermal condition not ok | Warning | SNMP | | Live migration | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | Mainboard failure | Critical | Zabbix (IPMI) | | Switch to hot standby | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | OS crash (e.g. kernel panic) | Critical | Zabbix | | Switch to hot standby | ++------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| Hypervisor | System has restarted | Critical | Zabbix | | Switch to hot standby | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | Hypervisor failure | Warning/Critical | Zabbix/Ceilometer | | Evacuation/switch to hot standby | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | Zabbix/Ceilometer is unreachable | Warning | ? | | Live migration | ++------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| Network | SDN/OpenFlow switch, controller degraded/failed | Critical | ? | | Switch to hot standby or reconfigure virtual network topology | ++ +---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ +| | Hardware failure of physical switch/router | Warning | SNMP | Redundancy of physical infrastructure is reduced or no longer available | Live migration if possible, otherwise evacuation | ++------------------+---------------------------------------------------------------------------------------------------------------------------+------------------+-------------------+------------------------------------------------------------------------------------------+----------------------------------------------------------------------+ + +.. + vim: set tabstop=4 expandtab textwidth=80: + diff --git a/requirements/index.rst b/requirements/index.rst index 8495365d..61046c3f 100644 --- a/requirements/index.rst +++ b/requirements/index.rst @@ -59,6 +59,7 @@ Doctor: Fault Management and Maintenance 04-gaps.rst 05-implementation.rst 06-summary.rst + 07-annex.rst .. include:: 99-references.rst |