diff options
author | Ryota MIBU <r-mibu@cq.jp.nec.com> | 2015-11-26 23:48:06 +0900 |
---|---|---|
committer | Ryota MIBU <r-mibu@cq.jp.nec.com> | 2015-12-02 00:14:07 +0900 |
commit | 4b620af0a7c1b34f42241195661627304e993236 (patch) | |
tree | 24dc64ad4ca0548d697d40f7ebd6db627f9448a4 /docs/requirements/05-implementation.rst | |
parent | c2f8523fe12c93813b8e459d093f0111c9dc1f31 (diff) |
change dirs to use new opnfv doc build script
Change-Id: Icfc17b1370fc111e0e9919f2f1c1d9ea8aee2702
Signed-off-by: Ryota MIBU <r-mibu@cq.jp.nec.com>
Diffstat (limited to 'docs/requirements/05-implementation.rst')
-rw-r--r-- | docs/requirements/05-implementation.rst | 837 |
1 files changed, 837 insertions, 0 deletions
diff --git a/docs/requirements/05-implementation.rst b/docs/requirements/05-implementation.rst new file mode 100644 index 00000000..e7f35158 --- /dev/null +++ b/docs/requirements/05-implementation.rst @@ -0,0 +1,837 @@ +Detailed architecture and interface specification +================================================= + +This section describes a detailed implementation plan, which is based on the +high level architecture introduced in Section 3. Section 5.1 describes the +functional blocks of the Doctor architecture, which is followed by a high level +message flow in Section 5.2. Section 5.3 provides a mapping of selected existing +open source components to the building blocks of the Doctor architecture. +Thereby, the selection of components is based on their maturity and the gap +analysis executed in Section 4. Sections 5.4 and 5.5 detail the specification of +the related northbound interface and the related information elements. Finally, +Section 5.6 provides a first set of blueprints to address selected gaps required +for the realization functionalities of the Doctor project. + +.. _impl_fb: + +Functional Blocks +----------------- + +This section introduces the functional blocks to form the VIM. OpenStack was +selected as the candidate for implementation. Inside the VIM, 4 different +building blocks are defined (see :numref:`figure6`). + +.. figure:: images/figure6.png + :name: figure6 + :width: 100% + + Functional blocks + +Monitor +^^^^^^^ + +The Monitor module has the responsibility for monitoring the virtualized +infrastructure. There are already many existing tools and services (e.g. Zabbix) +to monitor different aspects of hardware and software resources which can be +used for this purpose. + +Inspector +^^^^^^^^^ + +The Inspector module has the ability a) to receive various failure notifications +regarding physical resource(s) from Monitor module(s), b) to find the affected +virtual resource(s) by querying the resource map in the Controller, and c) to +update the state of the virtual resource (and physical resource). + +The Inspector has drivers for different types of events and resources to +integrate any type of Monitor and Controller modules. It also uses a failure +policy database to decide on the failure selection and aggregation from raw +events. This failure policy database is configured by the Administrator. + +The reason for separation of the Inspector and Controller modules is to make the +Controller focus on simple operations by avoiding a tight integration of various +health check mechanisms into the Controller. + +Controller +^^^^^^^^^^ + +The Controller is responsible for maintaining the resource map (i.e. the mapping +from physical resources to virtual resources), accepting update requests for the +resource state(s) (exposing as provider API), and sending all failure events +regarding virtual resources to the Notifier. Optionally, the Controller has the +ability to force the state of a given physical resource to down in the resource +mapping when it receives failure notifications from the Inspector for that +given physical resource. +The Controller also re-calculates the capacity of the NVFI when receiving a +failure notification for a physical resource. + +In a real-world deployment, the VIM may have several controllers, one for each +resource type, such as Nova, Neutron and Cinder in OpenStack. Each controller +maintains a database of virtual and physical resources which shall be the master +source for resource information inside the VIM. + +Notifier +^^^^^^^^ + +The focus of the Notifier is on selecting and aggregating failure events +received from the controller based on policies mandated by the Consumer. +Therefore, it allows the Consumer to subscribe for alarms regarding virtual +resources using a method such as API endpoint. After receiving a fault +event from a Controller, it will notify the fault to the Consumer by referring +to the alarm configuration which was defined by the Consumer earlier on. + +To reduce complexity of the Controller, it is a good approach for the +Controllers to emit all notifications without any filtering mechanism and have +another service (i.e. Notifier) handle those notifications properly. This is the +general philosophy of notifications in OpenStack. Note that a fault message +consumed by the Notifier is different from the fault message received by the +Inspector; the former message is related to virtual resources which are visible +to users with relevant ownership, whereas the latter is related to raw devices +or small entities which should be handled with an administrator privilege. + +The northbound interface between the Notifier and the Consumer/Administrator is +specified in :ref:`impl_nbi`. + +Sequence +-------- + +Fault Management +^^^^^^^^^^^^^^^^ + +The detailed work flow for fault management is as follows (see also :numref:`figure7`): + +1. Request to subscribe to monitor specific virtual resources. A query filter + can be used to narrow down the alarms the Consumer wants to be informed + about. +2. Each subscription request is acknowledged with a subscribe response message. + The response message contains information about the subscribed virtual + resources, in particular if a subscribed virtual resource is in "alarm" + state. +3. The NFVI sends monitoring events for resources the VIM has been subscribed + to. Note: this subscription message exchange between the VIM and NFVI is not + shown in this message flow. +4. Event correlation, fault detection and aggregation in VIM. +5. Database lookup to find the virtual resources affected by the detected fault. +6. Fault notification to Consumer. +7. The Consumer switches to standby configuration (STBY) +8. Instructions to VIM requesting certain actions to be performed on the + affected resources, for example migrate/update/terminate specific + resource(s). After reception of such instructions, the VIM is executing the + requested action, e.g. it will migrate or terminate a virtual resource. + + a. Query request from Consumer to VIM to get information about the current + status of a resource. + b. Response to the query request with information about the current status of + the queried resource. In case the resource is in "fault" state, information + about the related fault(s) is returned. + +In order to allow for quick reaction to failures, the time interval between +fault detection in step 3 and the corresponding recovery actions in step 7 and 8 +shall be less than 1 second. + +.. figure:: images/figure7.png + :name: figure7 + :width: 100% + + Fault management work flow + +.. figure:: images/figure8.png + :name: figure8 + :width: 100% + + Fault management scenario + +:numref:`figure8` shows a more detailed message flow (Steps 4 to 6) between +the 4 building blocks introduced in :ref:`impl_fb`. + +4. The Monitor observed a fault in the NFVI and reports the raw fault to the + Inspector. + The Inspector filters and aggregates the faults using pre-configured + failure policies. + +5. + a) The Inspector queries the Resource Map to find the virtual resources + affected by the raw fault in the NFVI. + b) The Inspector updates the state of the affected virtual resources in the + Resource Map. + c) The Controller observes a change of the virtual resource state and informs + the Notifier about the state change and the related alarm(s). + Alternatively, the Inspector may directly inform the Notifier about it. + +6. The Notifier is performing another filtering and aggregation of the changes + and alarms based on the pre-configured alarm configuration. Finally, a fault + notification is sent to northbound to the Consumer. + +NFVI Maintenance +^^^^^^^^^^^^^^^^ + +The detailed work flow for NFVI maintenance is shown in :numref:`figure9` +and has the following steps. Note that steps 1, 2, and 5 to 8a in the NFVI +maintenance work flow are very similar to the steps in the fault management work +flow and share a similar implementation plan in Release 1. + +1. Subscribe to fault/maintenance notifications. +2. Response to subscribe request. +3. Maintenance trigger received from administrator. +4. VIM switches NFVI resources to "maintenance" state. This, e.g., means they + should not be used for further allocation/migration requests +5. Database lookup to find the virtual resources affected by the detected + maintenance operation. +6. Maintenance notification to Consumer. +7. The Consumer switches to standby configuration (STBY) +8. Instructions from Consumer to VIM requesting certain recovery actions to be + performed (step 7a). After reception of such instructions, the VIM is + executing the requested action in order to empty the physical resources (step + 7b). +9. Maintenance response from VIM to inform the Administrator that the physical + machines have been emptied (or the operation resulted in an error state). +10. Administrator is coordinating and executing the maintenance operation/work + on the NFVI. + + A) Query request from Administrator to VIM to get information about the + current state of a resource. + B) Response to the query request with information about the current state of + the queried resource(s). In case the resource is in "maintenance" state, + information about the related maintenance operation is returned. + +.. figure:: images/figure9.png + :name: figure9 + :width: 100% + + NFVI maintenance work flow + +.. figure:: images/figure10.png + :name: figure10 + :width: 100% + + NFVI Maintenance implementation plan + +:numref:`figure10` shows a more detailed message flow (Steps 4 to 6) +between the 4 building blocks introduced in Section 5.1.. + +3. The Administrator is sending a StateChange request to the Controller residing + in the VIM. +4. The Controller queries the Resource Map to find the virtual resources + affected by the planned maintenance operation. +5. + + a) The Controller updates the state of the affected virtual resources in the + Resource Map database. + + b) The Controller informs the Notifier about the virtual resources that will + be affected by the maintenance operation. + +6. A maintenance notification is sent to northbound to the Consumer. + +... + +9. The Controller informs the Administrator after the physical resources have + been freed. + + + +Implementation plan for OPNFV Release 1 +--------------------------------------- + +Fault management +^^^^^^^^^^^^^^^^ + +:numref:`figure11` shows the implementation plan based on OpenStack and +related components as planned for Release 1. Hereby, the Monitor can be realized +by Zabbix. The Controller is realized by OpenStack Nova [NOVA]_, Neutron +[NEUT]_, and Cinder [CIND]_ for compute, network, and storage, +respectively. The Inspector can be realized by Monasca [MONA]_ or a simple +script querying Nova in order to map between physical and virtual resources. The +Notifier will be realized by Ceilometer [CEIL]_ receiving failure events +on its notification bus. + +:numref:`figure12` shows the inner-workings of Ceilometer. After receiving +an "event" on its notification bus, first a notification agent will grab the +event and send a "notification" to the Collector. The collector writes the +notifications received to the Ceilometer databases. + +In the existing Ceilometer implementation, an alarm evaluator is periodically +polling those databases through the APIs provided. If it finds new alarms, it +will evaluate them based on the pre-defined alarm configuration, and depending +on the configuration, it will hand a message to the Alarm Notifier, which in +turn will send the alarm message northbound to the Consumer. :numref:`figure12` +also shows an optimized work flow for Ceilometer with the goal to +reduce the delay for fault notifications to the Consumer. The approach is to +implement a new notification agent (called "publisher" in Ceilometer +terminology) which is directly sending the alarm through the "Notification Bus" +to a new "Notification-driven Alarm Evaluator (NAE)" (see Sections 5.6.2 and +5.6.3), thereby bypassing the Collector and avoiding the additional delay of the +existing polling-based alarm evaluator. The NAE is similar to the OpenStack +"Alarm Evaluator", but is triggered by incoming notifications instead of +periodically polling the OpenStack "Alarms" database for new alarms. The +Ceilometer "Alarms" database can hold three states: "normal", "insufficient +data", and "fired". It is representing a persistent alarm database. In order to +realize the Doctor requirements, we need to define new "meters" in the database +(see Section 5.6.1). + +.. figure:: images/figure11.png + :name: figure11 + :width: 100% + + Implementation plan in OpenStack (OPNFV Release 1 ”Arno”) + + +.. figure:: images/figure12.png + :name: figure12 + :width: 100% + + Implementation plan in Ceilometer architecture + + +NFVI Maintenance +^^^^^^^^^^^^^^^^ + +For NFVI Maintenance, a quite similar implementation plan exists. Instead of a +raw fault being observed by the Monitor, the Administrator is sending a +Maintenance Request through the northbound interface towards the Controller +residing in the VIM. Similar to the Fault Management use case, the Controller +(in our case OpenStack Nova) will send a maintenance event to the Notifier (i.e. +Ceilometer in our implementation). Within Ceilometer, the same workflow as +described in the previous section applies. In addition, the Controller(s) will +take appropriate actions to evacuate the physical machines in order to prepare +them for the planned maintenance operation. After the physical machines are +emptied, the Controller will inform the Administrator that it can initiate the +maintenance. + +Information elements +-------------------- + +This section introduces all attributes and information elements used in the +messages exchange on the northbound interfaces between the VIM and the VNFO and +VNFM. + +Note: The information elements will be aligned with current work in ETSI NFV IFA +working group. + + +Simple information elements: + +* SubscriptionID: identifies a subscription to receive fault or maintenance + notifications. +* NotificationID: identifies a fault or maintenance notification. +* VirtualResourceID (Identifier): identifies a virtual resource affected by a + fault or a maintenance action of the underlying physical resource. +* PhysicalResourceID (Identifier): identifies a physical resource affected by a + fault or maintenance action. +* VirtualResourceState (String): state of a virtual resource, e.g. "normal", + "maintenance", "down", "error". +* PhysicalResourceState (String): state of a physical resource, e.g. "normal", + "maintenance", "down", "error". +* VirtualResourceType (String): type of the virtual resource, e.g. "virtual + machine", "virtual memory", "virtual storage", "virtual CPU", or "virtual + NIC". +* FaultID (Identifier): identifies the related fault in the underlying physical + resource. This can be used to correlate different fault notifications caused + by the same fault in the physical resource. +* FaultType (String): Type of the fault. The allowed values for this parameter + depend on the type of the related physical resource. For example, a resource + of type "compute hardware" may have faults of type "CPU failure", "memory + failure", "network card failure", etc. +* Severity (Integer): value expressing the severity of the fault. The higher the + value, the more severe the fault. +* MinSeverity (Integer): value used in filter information elements. Only faults + with a severity higher than the MinSeverity value will be notified to the + Consumer. +* EventTime (Datetime): Time when the fault was observed. +* EventStartTime and EventEndTime (Datetime): Datetime range that can be used in + a FaultQueryFilter to narrow down the faults to be queried. +* ProbableCause: information about the probable cause of the fault. +* CorrelatedFaultID (Integer): list of other faults correlated to this fault. +* isRootCause (Boolean): Parameter indicating if this fault is the root for + other correlated faults. If TRUE, then the faults listed in the parameter + CorrelatedFaultID are caused by this fault. +* FaultDetails (Key-value pair): provides additional information about the + fault, e.g. information about the threshold, monitored attributes, indication + of the trend of the monitored parameter. +* FirmwareVersion (String): current version of the firmware of a physical + resource. +* HypervisorVersion (String): current version of a hypervisor. +* ZoneID (Identifier): Identifier of the resource zone. A resource zone is the + logical separation of physical and software resources in an NFVI deployment + for physical isolation, redundancy, or administrative designation. +* Metadata (Key-Value-Pairs): provides additional information of a physical + resource in maintenance/error state. + +Complex information elements (see also UML diagrams in :numref:`figure13` +and :numref:`figure14`): + +* VirtualResourceInfoClass: + + + VirtualResourceID [1] (Identifier) + + VirtualResourceState [1] (String) + + Faults [0..*] (FaultClass): For each resource, all faults + including detailed information about the faults are provided. + +* FaultClass: The parameters of the FaultClass are partially based on ETSI TS + 132 111-2 (V12.1.0) [*]_, which is specifying fault management in 3GPP, in + particular describing the information elements used for alarm notifications. + + - FaultID [1] (Identifier) + - FaultType [1] + - Severity [1] (Integer) + - EventTime [1] (Datetime) + - ProbableCause [1] + - CorrelatedFaultID [0..*] (Identifier) + - FaultDetails [0..*] (Key-value pair) + +.. [*] http://www.etsi.org/deliver/etsi_ts/132100_132199/13211102/12.01.00_60/ts_13211102v120100p.pdf + +* SubscribeFilterClass + + - VirtualResourceType [0..*] (String) + - VirtualResourceID [0..*] (Identifier) + - FaultType [0..*] (String) + - MinSeverity [0..1] (Integer) + +* FaultQueryFilterClass: narrows down the FaultQueryRequest, for example it + limits the query to certain physical resources, a certain zone, a given fault + type/severity/cause, or a specific FaultID. + + - VirtualResourceType [0..*] (String) + - VirtualResourceID [0..*] (Identifier) + - FaultType [0..*] (String) + - MinSeverity [0..1] (Integer) + - EventStartTime [0..1] (Datetime) + - EventEndTime [0..1] (Datetime) + +* PhysicalResourceStateClass: + + - PhysicalResourceID [1] (Identifier) + - PhysicalResourceState [1] (String): mandates the new state of the physical + resource. + +* PhysicalResourceInfoClass: + + - PhysicalResourceID [1] (Identifier) + - PhysicalResourceState [1] (String) + - FirmwareVersion [0..1] (String) + - HypervisorVersion [0..1] (String) + - ZoneID [0..1] (Identifier) + +* StateQueryFilterClass: narrows down a StateQueryRequest, for example it limits + the query to certain physical resources, a certain zone, or a given resource + state (e.g., only resources in "maintenance" state). + + - PhysicalResourceID [1] (Identifier) + - PhysicalResourceState [1] (String) + - ZoneID [0..1] (Identifier) + +.. _impl_nbi: + +Detailed northbound interface specification +------------------------------------------- + +This section is specifying the northbound interfaces for fault management and +NFVI maintenance between the VIM on the one end and the Consumer and the +Administrator on the other ends. For each interface all messages and related +information elements are provided. + +Note: The interface definition will be aligned with current work in ETSI NFV IFA +working group . + +All of the interfaces described below are produced by the VIM and consumed by +the Consumer or Administrator. + +Fault management interface +^^^^^^^^^^^^^^^^^^^^^^^^^^ + +This interface allows the VIM to notify the Consumer about a virtual resource +that is affected by a fault, either within the virtual resource itself or by the +underlying virtualization infrastructure. The messages on this interface are +shown in :numref:`figure13` and explained in detail in the following +subsections. + +Note: The information elements used in this section are described in detail in +Section 5.4. + +.. figure:: images/figure13.png + :name: figure13 + :width: 100% + + Fault management NB I/F messages + + +SubscribeRequest (Consumer -> VIM) +__________________________________ + +Subscription from Consumer to VIM to be notified about faults of specific +resources. The faults to be notified about can be narrowed down using a +subscribe filter. + +Parameters: + +- SubscribeFilter [1] (SubscribeFilterClass): Optional information to narrow + down the faults that shall be notified to the Consumer, for example limit to + specific VirtualResourceID(s), severity, or cause of the alarm. + +SubscribeResponse (VIM -> Consumer) +___________________________________ + +Response to a subscribe request message including information about the +subscribed resources, in particular if they are in "fault/error" state. + +Parameters: + +* SubscriptionID [1] (Identifier): Unique identifier for the subscription. It + can be used to delete or update the subscription. +* VirtualResourceInfo [0..*] (VirtualResourceInfoClass): Provides additional + information about the subscribed resources, i.e., a list of the related + resources, the current state of the resources, etc. + +FaultNotification (VIM -> Consumer) +___________________________________ + +Notification about a virtual resource that is affected by a fault, either within +the virtual resource itself or by the underlying virtualization infrastructure. +After reception of this request, the Consumer will decide on the optimal +action to resolve the fault. This includes actions like switching to a hot +standby virtual resource, migration of the fault virtual resource to another +physical machine, termination of the faulty virtual resource and instantiation +of a new virtual resource in order to provide a new hot standby resource. +Existing resource management interfaces and messages between the Consumer and +the VIM can be used for those actions, and there is no need to define additional +actions on the Fault Management Interface. + +Parameters: + +* NotificationID [1] (Identifier): Unique identifier for the notification. +* VirtualResourceInfo [1..*] (VirtualResourceInfoClass): List of faulty + resources with detailed information about the faults. + +FaultQueryRequest (Consumer -> VIM) +___________________________________ + +Request to find out about active alarms at the VIM. A FaultQueryFilter can be +used to narrow down the alarms returned in the response message. + +Parameters: + +* FaultQueryFilter [1] (FaultQueryFilterClass): narrows down the + FaultQueryRequest, for example it limits the query to certain physical + resources, a certain zone, a given fault type/severity/cause, or a specific + FaultID. + +FaultQueryResponse (VIM -> Consumer) +____________________________________ + +List of active alarms at the VIM matching the FaultQueryFilter specified in the +FaultQueryRequest. + +Parameters: + +* VirtualResourceInfo [0..*] (VirtualResourceInfoClass): List of faulty + resources. For each resource all faults including detailed information about + the faults are provided. + +NFVI maintenance +^^^^^^^^^^^^^^^^ + +The NFVI maintenance interfaces Consumer-VIM allows the Consumer to subscribe to +maintenance notifications provided by the VIM. The related maintenance interface +Administrator-VIM allows the Administrator to issue maintenance requests to the +VIM, i.e. requesting the VIM to take appropriate actions to empty physical +machine(s) in order to execute maintenance operations on them. The interface +also allows the Administrator to query the state of physical machines, e.g., in +order to get details in the current status of the maintenance operation like a +firmware update. + +The messages defined in these northbound interfaces are shown in :numref:`figure14` +and described in detail in the following subsections. + +.. figure:: images/figure14.png + :name: figure14 + :width: 100% + + NFVI maintenance NB I/F messages + +SubscribeRequest (Consumer -> VIM) +__________________________________ + +Subscription from Consumer to VIM to be notified about maintenance operations +for specific virtual resources. The resources to be informed about can be +narrowed down using a subscribe filter. + +Parameters: + +* SubscribeFilter [1] (SubscribeFilterClass): Information to narrow down the + faults that shall be notified to the Consumer, for example limit to specific + virtual resource type(s). + +SubscribeResponse (VIM -> Consumer) +___________________________________ + +Response to a subscribe request message, including information about the +subscribed virtual resources, in particular if they are in "maintenance" state. + +Parameters: + +* SubscriptionID [1] (Identifier): Unique identifier for the subscription. It + can be used to delete or update the subscription. +* VirtualResourceInfo [0..*] (VirtalResourceInfoClass): Provides additional + information about the subscribed virtual resource(s), e.g., the ID, type and + current state of the resource(s). + +MaintenanceNotification (VIM -> Consumer) +_________________________________________ + +Notification about a physical resource switched to "maintenance" state. After +reception of this request, the Consumer will decide on the optimal action to +address this request, e.g., to switch to the standby (STBY) configuration. + +Parameters: + +* VirtualResourceInfo [1..*] (VirtualResourceInfoClass): List of virtual + resources where the state has been changed to maintenance. + +StateChangeRequest (Administrator -> VIM) +_________________________________________ + +Request to change the state of a list of physical resources, e.g. to +"maintenance" state, in order to prepare them for a planned maintenance +operation. + +Parameters: + +* PhysicalResourceState [1..*] (PhysicalResourceStateClass) + +StateChangeResponse (VIM -> Administrator) +__________________________________________ + +Response message to inform the Administrator that the requested resources are +now in maintenance state (or the operation resulted in an error) and the +maintenance operation(s) can be executed. + +Parameters: + +* PhysicalResourceInfo [1..*] (PhysicalResourceInfoClass) + +StateQueryRequest (Administrator -> VIM) +________________________________________ + +In this procedure, the Administrator would like to get the information about +physical machine(s), e.g. their state ("normal", "maintenance"), firmware +version, hypervisor version, update status of firmware and hypervisor, etc. It +can be used to check the progress during firmware update and the confirmation +after update. A filter can be used to narrow down the resources returned in the +response message. + +Parameters: + +* StateQueryFilter [1] (StateQueryFilterClass): narrows down the + StateQueryRequest, for example it limits the query to certain physical + resources, a certain zone, or a given resource state. + +StateQueryResponse (VIM -> Administrator) +_________________________________________ + +List of physical resources matching the filter specified in the +StateQueryRequest. + +Parameters: + +* PhysicalResourceInfo [0..*] (PhysicalResourceInfoClass): List of physical + resources. For each resource, information about the current state, the + firmware version, etc. is provided. + +Blueprints +---------- + +This section is listing a first set of blueprints that have been proposed by the +Doctor project to the open source community. Further blueprints addressing other +gaps identified in Section 4 will be submitted at a later stage of the OPNFV. In +this section the following definitions are used: + +* "Event" is a message emitted by other OpenStack services such as Nova and + Neutron and is consumed by the "Notification Agents" in Ceilometer. +* "Notification" is a message generated by a "Notification Agent" in Ceilometer + based on an "event" and is delivered to the "Collectors" in Ceilometer that + store those notifications (as "sample") to the Ceilometer "Databases". + +Instance State Notification (Ceilometer) [*]_ +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +The Doctor project is planning to handle "events" and "notifications" regarding +Resource Status; Instance State, Port State, Host State, etc. Currently, +Ceilometer already receives "events" to identify the state of those resources, +but it does not handle and store them yet. This is why we also need a new event +definition to capture those resource states from "events" created by other +services. + +This BP proposes to add a new compute notification state to handle events from +an instance (server) from nova. It also creates a new meter "instance.state" in +OpenStack. + +.. [*] https://etherpad.opnfv.org/p/doctor_bps + +Event Publisher for Alarm (Ceilometer) [*]_ +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +**Problem statement:** + + The existing "Alarm Evaluator" in OpenStack Ceilometer is periodically + querying/polling the databases in order to check all alarms independently from + other processes. This is adding additional delay to the fault notification + send to the Consumer, whereas one requirement of Doctor is to react on faults + as fast as possible. + + The existing message flow is shown in :numref:`figure12`: after receiving + an "event", a "notification agent" (i.e. "event publisher") will send a + "notification" to a "Collector". The "collector" is collecting the + notifications and is updating the Ceilometer "Meter" database that is storing + information about the "sample" which is capured from original "event". The + "Alarm Evaluator" is periodically polling this databases then querying "Meter" + database based on each alarm configuration. + + In the current Ceilometer implementation, there is no possibility to directly + trigger the "Alarm Evaluator" when a new "event" was received, but the "Alarm + Evaluator" will only find out that requires firing new notification to the + Consumer when polling the database. + +**Change/feature request:** + + This BP proposes to add a new "event publisher for alarm", which is bypassing + several steps in Ceilometer in order to avoid the polling-based approach of + the existing Alarm Evaluator that makes notification slow to users. + + After receiving an "(alarm) event" by listening on the Ceilometer message + queue ("notification bus"), the new "event publisher for alarm" immediately + hands a "notification" about this event to a new Ceilometer component + "Notification-driven alarm evaluator" proposed in the other BP (see Section + 5.6.3). + + Note, the term "publisher" refers to an entity in the Ceilometer architecture + (it is a "notification agent"). It offers the capability to provide + notifications to other services outside of Ceilometer, but it is also used to + deliver notifications to other Ceilometer components (e.g. the "Collectors") + via the Ceilometer "notification bus". + +**Implementation detail** + + * "Event publisher for alarm" is part of Ceilometer + * The standard AMQP message queue is used with a new topic string. + * No new interfaces have to be added to Ceilometer. + * "Event publisher for Alarm" can be configured by the Administrator of + Ceilometer to be used as "Notification Agent" in addition to the existing + "Notifier" + * Existing alarm mechanisms of Ceilometer can be used allowing users to + configure how to distribute the "notifications" transformed from "events", + e.g. there is an option whether an ongoing alarm is re-issued or not + ("repeat_actions"). + +.. [*] https://etherpad.opnfv.org/p/doctor_bps + +Notification-driven alarm evaluator (Ceilometer) [*]_ +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +**Problem statement:** + +The existing "Alarm Evaluator" in OpenStack Ceilometer is periodically +querying/polling the databases in order to check all alarms independently from +other processes. This is adding additional delay to the fault notification send +to the Consumer, whereas one requirement of Doctor is to react on faults as fast +as possible. + +**Change/feature request:** + +This BP is proposing to add an alternative "Notification-driven Alarm Evaluator" +for Ceilometer that is receiving "notifications" sent by the "Event Publisher +for Alarm" described in the other BP. Once this new "Notification-driven Alarm +Evaluator" received "notification", it finds the "alarm" configurations which +may relate to the "notification" by querying the "alarm" database with some keys +i.e. resource ID, then it will evaluate each alarm with the information in that +"notification". + +After the alarm evaluation, it will perform the same way as the existing "alarm +evaluator" does for firing alarm notification to the Consumer. Similar to the +existing Alarm Evaluator, this new "Notification-driven Alarm Evaluator" is +aggregating and correlating different alarms which are then provided northbound +to the Consumer via the OpenStack "Alarm Notifier". The user/administrator can +register the alarm configuration via existing Ceilometer API [*]_. Thereby, he +can configure whether to set an alarm or not and where to send the alarms to. + +**Implementation detail** + +* The new "Notification-driven Alarm Evaluator" is part of Ceilometer. +* Most of the existing source code of the "Alarm Evaluator" can be re-used to + implement this BP +* No additional application logic is needed +* It will access the Ceilometer Databases just like the existing "Alarm + evaluator" +* Only the polling-based approach will be replaced by a listener for + "notifications" provided by the "Event Publisher for Alarm" on the Ceilometer + "notification bus". +* No new interfaces have to be added to Ceilometer. + + +.. [*] https://etherpad.opnfv.org/p/doctor_bps +.. [*] https://wiki.openstack.org/wiki/Ceilometer/Alerting + +Report host fault to update server state immediately (Nova) [*]_ +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +**Problem statement:** + +* Nova state change for failed or unreachable host is slow and does not reliably + state host is down or not. This might cause same server instance to run twice + if action taken to evacuate instance to another host. +* Nova state for server(s) on failed host will not change, but remains active + and running. This gives the user false information about server state. +* VIM northbound interface notification of host faults towards VNFM and NFVO + should be in line with OpenStack state. This fault notification is a Telco + requirement defined in ETSI and will be implemented by OPNFV Doctor project. +* Openstack user cannot make HA actions fast and reliably by trusting server + state and host state. + +**Proposed change:** + +There needs to be a new API for Admin to state host is down. This API is used to +mark services running in host down to reflect the real situation. + +Example on compute node is: + +* When compute node is up and running::: + + vm_state: activeand power_state: running + nova-compute state: up status: enabled + +* When compute node goes down and new API is called to state host is down::: + + vm_state: stopped power_state: shutdown + nova-compute state: down status: enabled + +**Alternatives:** + +There is no attractive alternative to detect all different host faults than to +have an external tool to detect different host faults. For this kind of tool to +exist there needs to be new API in Nova to report fault. Currently there must be +some kind of workarounds implemented as cannot trust or get the states from +OpenStack fast enough. + +.. [*] https://blueprints.launchpad.net/nova/+spec/update-server-state-immediately + +Other related BPs +^^^^^^^^^^^^^^^^^ + +This section lists some BPs related to Doctor, but proposed by drafters outside +the OPNFV community. + +pacemaker-servicegroup-driver [*]_ +__________________________________ + +This BP will detect and report host down quite fast to OpenStack. This however +might not work properly for example when management network has some problem and +host reported faulty while VM still running there. This might lead to launching +same VM instance twice causing problems. Also NB IF message needs fault reason +and for that the source needs to be a tool that detects different kind of faults +as Doctor will be doing. Also this BP might need enhancement to change server +and service states correctly. + +.. [*] https://blueprints.launchpad.net/nova/+spec/pacemaker-servicegroup-driver + +.. + vim: set tabstop=4 expandtab textwidth=80: |