diff options
author | Umar Farooq <umar.farooq@neclab.eu> | 2017-07-13 12:20:56 +0200 |
---|---|---|
committer | Ryota Mibu <r-mibu@cq.jp.nec.com> | 2017-08-09 04:39:54 +0000 |
commit | 282369b6fd58a78e6a7c91f21b331363d4ed0fb3 (patch) | |
tree | 3dc95a2c16ca948627df6fb93629a3652e620211 /docs/development/manuals/monitors.rst | |
parent | db6d9cdcb37fee810fdf59e4d96b9a5139b5c8b7 (diff) |
Add Collectd as a Monitor Type
A plugin for collectd is added to use collectd on compute as a
monitor type. Monitor files are updated accordingly.
The inspector now listens on all interfaces instead of only
localhost to enable it to communicate with compute node.
JIRA: DOCTOR-86
JIRA: DOCTOR-101
Change-Id: Idc834d428152e4687020eff7d8db36a652b1bf86
Signed-off-by: Umar Farooq <umar.farooq@neclab.eu>
Diffstat (limited to 'docs/development/manuals/monitors.rst')
-rw-r--r-- | docs/development/manuals/monitors.rst | 36 |
1 files changed, 36 insertions, 0 deletions
diff --git a/docs/development/manuals/monitors.rst b/docs/development/manuals/monitors.rst new file mode 100644 index 00000000..0d22b1de --- /dev/null +++ b/docs/development/manuals/monitors.rst @@ -0,0 +1,36 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 + +Monitor Types and Limitations +============================= + +Currently there are two monitor types supported: sample and collectd + +Sample Monitor +-------------- + +Sample monitor type pings the compute host from the control host and calculates the +notification time after the ping timeout. +Also if inspector type is sample, the compute node needs to communicate with the control +node on port 12345. This port needs to be opened for incomming traffic on control node. + +Collectd Monitor +---------------- + +Collectd monitor type uses collectd daemon running ovs_events plugin. Collectd runs on +compute to send instant notification to the control node. The notification time is +calculated by using the difference of time at which compute node sends notification to +control node and the time at which consumer is notified. The time on control and compute +node has to be synchronized for this reason. For further details on setting up collectd +on the compute node, use the following link: +http://docs.opnfv.org/en/stable-danube/submodules/barometer/docs/release/userguide/feature.userguide.html#id18 + +Collectd monitors an interface managed by OVS. If the interface is not be assigned +an IP, the user has to provide the name of interface to be monitored. The command to +launch the doctor test in that case is: +MONITOR_TYPE=collectd INSPECTOR_TYPE=sample INTERFACE_NAME=example_iface ./run.sh + +If the interface name or IP is not provided, the collectd monitor type will monitor the +default management interface. This may result in the failure of doctor run.sh test case. +The test case sets the monitored interface down and if the inspector (sample or congress) +is running on the same subnet, collectd monitor will not be able to communicate with it. |