diff options
author | Shubham Mishra <shivam828787@gmail.com> | 2020-06-16 18:42:58 +0530 |
---|---|---|
committer | Shubham Mishra <shivam828787@gmail.com> | 2020-06-16 20:57:22 +0530 |
commit | b5609493e9a3366a64bcf5931322bda96d965854 (patch) | |
tree | 7bc88a86442e8260eaf66ea0fd7f19e9951f77db /hdv/redfish/conf/cases.yaml | |
parent | 06bf8cf347d8af6740ab5df842abebf17dabac30 (diff) |
Merged depends.yml and cases.yml for general cases
Updated create_real_url() function to retreive and process parent url to get child url.
All cases are indepedent now and order doesn't matter, same can be extended to exception cases too.
Change-Id: I77c9ad1b406fde01a7853872a515b560b9265871
Signed-off-by: Shubham Mishra <shivam828787@gmail.com>
Diffstat (limited to 'hdv/redfish/conf/cases.yaml')
-rw-r--r-- | hdv/redfish/conf/cases.yaml | 855 |
1 files changed, 452 insertions, 403 deletions
diff --git a/hdv/redfish/conf/cases.yaml b/hdv/redfish/conf/cases.yaml index 5609708..5d92689 100644 --- a/hdv/redfish/conf/cases.yaml +++ b/hdv/redfish/conf/cases.yaml @@ -1,22 +1,58 @@ --- -- case_name: set asset code +- case_name: get asset code case_sn: 1 expected_code: 200 expected_result: '{"AssetTag": "CM_cc@1234"}' group: asset managment header: null - method: PATCH - request_body: '{"AssetTag": "CM_cc@1234"}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id} -- case_name: get asset code - case_sn: 2 + method: GET + request_body: null + url: /redfish/v1/Systems/{system_id} + key_flag_dict: {"system_id": "Members"} +- case_name: check main board name + case_sn: 8 expected_code: 200 - expected_result: '{"AssetTag": "CM_cc@1234"}' + expected_result: '{"Oem":{"Mainboard": {"BoardName": "RS33M2C9S"}}}' group: asset managment header: null method: GET request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id} + url: /redfish/v1/Chassis/{chassis_id} + key_flag_dict: {"chassis_id": "Members"} +- case_name: check CPU amount + case_sn: 11 + expected_code: 200 + expected_result: '{"Members@odata.count": 2}' + group: compoment management + header: null + method: GET + request_body: null + url: /redfish/v1/Systems/{system_id}/Processors + key_flag_dict: {"system_id": "Members"} +- case_name: check CPU info + case_sn: 2 + expected_code: 200 + expected_result: '{ "count": 2, "Manufacturer": "Intel(R) Corporation", "MaxSpeedMHz": + 2300, "Model": "Intel(R) Xeon(R) Gold 5218N CPU @ 2.30GHz", "ProcessorArchitecture": + ["x86", "IA-64", "ARM", "MIPS", "OEM"], "Socket": [1, 2], "Status": { "Health": + "OK", "State": "Enabled" }, "TotalCores": 16, "TotalThreads": + 32}' + group: compoment management + header: null + method: GET + request_body: null + url: /redfish/v1/Systems/{system_id}/Processors/{cpu_id} + key_flag_dict: {"system_id": "Members", "cpu_id": "Members"} +- case_name: set asset code + case_sn: 1 + expected_code: 200 + expected_result: '{"AssetTag": "CM_cc@1234"}' + group: asset managment + header: null + method: PATCH + request_body: '{"AssetTag": "CM_cc@1234"}' + url: /redfish/v1/Systems/{system_id} + key_flag_dict: {"system_id": "Members"} - case_name: set host name case_sn: 3 expected_code: 200 @@ -25,7 +61,8 @@ header: null method: PATCH request_body: '{"HostName": "NFV-RPZJHZ-01B"}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id} + url: /redfish/v1/Systems/{system_id} + key_flag_dict: {"system_id": "Members"} - case_name: check host name case_sn: 4 expected_code: 200 @@ -34,7 +71,8 @@ header: null method: GET request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id} + url: /redfish/v1/Systems/{system_id} + key_flag_dict: {"system_id": "Members"} - case_name: check manufacturer case_sn: 5 expected_code: 200 @@ -43,7 +81,8 @@ header: null method: GET request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id} + url: /redfish/v1/Systems/{system_id} + key_flag_dict: {"system_id": "Members"} - case_name: check model case_sn: 6 expected_code: 200 @@ -52,7 +91,8 @@ header: null method: GET request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id} + url: /redfish/v1/Systems/{system_id} + key_flag_dict: {"system_id": "Members"} - case_name: check serial number case_sn: 7 expected_code: 200 @@ -61,7 +101,8 @@ header: null method: GET request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id} + url: /redfish/v1/Systems/{system_id} + key_flag_dict: {"system_id": "Members"} - case_name: check main board name case_sn: 8 expected_code: 200 @@ -70,7 +111,8 @@ header: null method: GET request_body: null - url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id} + url: /redfish/v1/Chassis/{chassis_id} + key_flag_dict: {"chassis_id": "Members"} - case_name: check main board serial number case_sn: 9 expected_code: 200 @@ -79,7 +121,8 @@ header: null method: GET request_body: null - url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id} + url: /redfish/v1/Chassis/{chassis_id} + key_flag_dict: {"chassis_id": "Members"} - case_name: check BIOS version case_sn: 10 expected_code: 200 @@ -88,7 +131,8 @@ header: null method: GET request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id} + url: /redfish/v1/Systems/{system_id} + key_flag_dict: {"system_id": "Members"} - case_name: check CPU amount case_sn: 11 expected_code: 200 @@ -97,7 +141,8 @@ header: null method: GET request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Processors + url: /redfish/v1/Systems/{system_id}/Processors + key_flag_dict: {"system_id": "Members"} - case_name: check CPU info case_sn: 12 expected_code: 200 @@ -110,7 +155,8 @@ header: null method: GET request_body: null - url: https://{bmc_ip}{cpu_id} + url: /redfish/v1/Systems/{system_id}/Processors/{cpu_id} + key_flag_dict: {"system_id": "Members","cpu_id": "Members"} - case_name: check memory mount case_sn: 13 expected_code: 200 @@ -119,7 +165,8 @@ header: null method: GET request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Memory + url: /redfish/v1/Systems/{system_id}/Memory + key_flag_dict: {"system_id": "Members"} - case_name: check memory information case_sn: 14 expected_code: 200 @@ -131,387 +178,389 @@ header: null method: GET request_body: null - url: https://{bmc_ip}{memory_id} -- case_name: check raid card amount - case_sn: 15 - expected_code: 200 - expected_result: '{"Members@odata.count": 1}' - group: compoment management - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Storages -- case_name: check raid card information - case_sn: 16 - expected_code: 200 - expected_result: '{ "count": 1, "StorageControllers": [ { "FirmwareVersion": - "2.62", "Manufacturer": "H3C", "Model": "N/A", "Status": - { "Health": "OK", "State": "Enabled" } } ]}' - group: compoment management - header: null - method: GET - request_body: null - url: https://{bmc_ip}{storage_id} -- case_name: check harddisk information - case_sn: 17 - expected_code: 200 - expected_result: '{ "count": 4, "CapacityBytes": [480102187008, 960193626112], "Location": - { "Info": "N/A", "InfoFormat": "DeviceName" }, "Manufacturer": - "ATA", "MediaType": "SSD", "Model": ["INTEL SSDSC2KB48", "INTEL SSDSC2KB96"], "Protocol": - "SATA", "Status": { "Health": "OK", "State": "Enabled" }}' - group: compoment management - header: null - method: GET - request_body: null - url: https://{bmc_ip}{drives_id} -- case_name: check network interface adapter information - case_sn: 18 - expected_code: 200 - expected_result: '{ "count": 3, "Manufacturer": "Mellanox", "Model": "NIC-620F-B2-25Gb-2P-1-X", "Name": - ["PCIeSlot2", "PCIeSlot3", "PCIeSlot6"], "Oem": { "Public": { "CardModel": - "2*25GE", "RootBDF": ["0000:17:00.0", "0000:17:02.0", "0000:AE:02.0"], } }, "Status": - { "Health": "OK", "State": "Enabled" }}' - group: compoment management - header: null - method: GET - request_body: null - url: https://{bmc_ip}{networkadapters_id} -- case_name: check network interface adapter port information - case_sn: 19 - expected_code: 200 - expected_result: '{ "count": 6, "AssociatedNetworkAddresses": [ "N/A" ], "Oem": - { "Public": { "BDF": "N/A", "PortType": "OpticalPort" } }, "PhysicalPortNumber": - ["1", "2"]}' - group: compoment management - header: null - method: GET - request_body: null - url: https://{bmc_ip}{networkports_id} -- case_name: check fans information - case_sn: 20 - expected_code: 200 - expected_result: '{ "FanSummary": { "Count": 6 }, "Fans": [ { "MemberId": - "N/A", "Oem": { "Public": { "SpeedRatio": - "N/A" } }, "Status": { "Health": - "OK", "State": "Enabled" } }, { "MemberId": - "N/A", "Oem": { "Public": { "SpeedRatio": - "N/A" } }, "Status": { "Health": - "OK", "State": "Enabled" } },{ "MemberId": - "N/A", "Oem": { "Public": { "SpeedRatio": - "N/A" } }, "Status": { "Health": - "OK", "State": "Enabled" } },{ "MemberId": - "N/A", "Oem": { "Public": { "SpeedRatio": - "N/A" } }, "Status": { "Health": - "OK", "State": "Enabled" } },{ "MemberId": - "N/A", "Oem": { "Public": { "SpeedRatio": - "N/A" } }, "Status": { "Health": - "OK", "State": "Enabled" } },{ "MemberId": - "N/A", "Oem": { "Public": { "SpeedRatio": - "N/A" } }, "Status": { "Health": - "OK", "State": "Enabled" } } ],}' - group: compoment management - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id}/Thermal -- case_name: check power amount - case_sn: 21 - expected_code: 200 - expected_result: '{ "DeviceMaxNum": { "PowerSupplyNum": 2},}' - group: compoment management - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id} -- case_name: check power detail info - case_sn: 22 - expected_code: 200 - expected_result: '{ "PowerControl": [ { "PowerConsumedWatts": - "N/A","Status":{ "Health": "OK", "State": "Enabled" } }, ], "PowerSupplies": - [ { "LineInputVoltage": "N/A", "MemberId": "1", "PowerCapacityWatts": - 800,"Status": { "Health": "OK", "State": "Enabled" } }, { "LineInputVoltage": - "N/A", "MemberId": "2", "PowerCapacityWatts": 800,"Status": - { "Health": "OK", "State": "Enabled" } } ],}' - group: compoment management - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id}/Power -- case_name: check logical dirve health status - case_sn: 23 - expected_code: 200 - expected_result: '{ "count": 2, "Name": "N/A", "Status": { "Health": - ["OK", "Critical"], "State": "Enabled" }}' - group: compoment management - header: null - method: GET - request_body: null - url: https://{bmc_ip}{volume_id} -- case_name: check server temperature air intake - case_sn: 24 - expected_code: 200 - expected_result: '{ "Temperatures": [ { "Name": "INPUT_TEMP", "ReadingCelsius": - "N/A", } ]}' - group: sensor management - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id}/Thermal -- case_name: check cpu temperature - case_sn: 25 - expected_code: 200 - expected_result: '{ "Temperatures": [ { "Name": "INPUT_TEMP", "ReadingCelsius": - "N/A", }, { "Name": "CPU1_TEMP", "ReadingCelsius": - "N/A", }, { "Name": "CPU2_TEMP", "ReadingCelsius": - "N/A", }, ]}' - group: sensor management - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id}/Thermal -- case_name: check server power state - case_sn: 26 - expected_code: 200 - expected_result: '{"PowerState": "On"}' - group: power management - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id} -- case_name: remote power on server - case_sn: 27 - expected_code: 200 - expected_result: '{"error":{"@Message.ExtendedInfo": [{"Message": "Successfully - Completed Request", "Severity":"OK"}]}}' - group: power management - header: null - method: POST - request_body: '{"ResetType": "On"}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Actions/ComputerSystem.Reset -- case_name: remote power off server - case_sn: 28 - expected_code: 200 - expected_result: '{"error":{"@Message.ExtendedInfo": [{"Message": "Successfully - Completed Request", "Severity":"OK"}]}}' - group: power management - header: null - method: POST - request_body: '{"ResetType": "GracefulShutdown"}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Actions/ComputerSystem.Reset -- case_name: remote reset server - case_sn: 29 - expected_code: 200 - expected_result: '{"error":{"@Message.ExtendedInfo": [{"Message": "Successfully - Completed Request", "Severity":"OK"}]}}' - group: power management - header: null - method: POST - request_body: '{"ResetType": "ForceRestart"}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Actions/ComputerSystem.Reset -- case_name: remote configure CPU in hyperthreading disabled - case_sn: 30 - expected_code: 200 - expected_result: '{"Attributes": {"ProcessorHyperThreading": "Disabled"}}' - group: remote configure - header: null - method: PATCH - request_body: '{ "Attributes": { "ProcessorHyperThreading": "Disabled" }}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings -- case_name: remote get CPU hyperthreading in disabled - case_sn: 31 - expected_code: 200 - expected_result: '{"Attributes": {"ProcessorHyperThreading": "Disabled"}}' - group: remote configure - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios -- case_name: remote configure CPU in hyperthreading enabled - case_sn: 32 - expected_code: 200 - expected_result: '{"Attributes": {"ProcessorHyperThreading": "Enabled"}}' - group: remote configure - header: null - method: PATCH - request_body: '{ "Attributes": { "ProcessorHyperThreading": "Enabled" }}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings -- case_name: remote get CPU hyperthreading in enabled - case_sn: 33 - expected_code: 200 - expected_result: '{"Attributes": {"ProcessorHyperThreading": "Enabled"}}' - group: remote configure - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios -- case_name: disable PXE mode - case_sn: 34 - expected_code: 200 - expected_result: '{ "Attributes": { "IPv4PXESupport": "Disabled" }}' - group: remote configure - header: null - method: PATCH - request_body: '{ "Attributes": { "IPv4PXESupport": "Disabled" }}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings -- case_name: check IPV4 PXE mode in disabled - case_sn: 35 - expected_code: 200 - expected_result: '{ "Attributes": { "IPv4PXESupport": "Disabled" }}' - group: remote configure - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios -- case_name: enable PXE mode - case_sn: 36 - expected_code: 200 - expected_result: '{ "Attributes": { "IPv4PXESupport": "Enabled" }}' - group: remote configure - header: null - method: PATCH - request_body: '{ "Attributes": { "IPv4PXESupport": "Enabled" }}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings -- case_name: check ipv4 PXE mode in enabled - case_sn: 37 - expected_code: 200 - expected_result: '{ "Attributes": { "IPv4PXESupport": "Enabled" }}' - group: remote configure - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios -- case_name: set boot type order - case_sn: 38 - expected_code: 200 - expected_result: '{ "Attributes": { "BootTypeOrder0": "HardDiskDrive", "BootTypeOrder1": - "DVDROMDrive", "BootTypeOrder2": "PXE", "BootTypeOrder3": - "Others", }}' - group: remote interface management - header: null - method: PATCH - request_body: '{ "Attributes": { "BootTypeOrder0": "HardDiskDrive", "BootTypeOrder1": - "DVDROMDrive", "BootTypeOrder2": "PXE", "BootTypeOrder3": - "Others", }}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings -- case_name: check boot order - case_sn: 39 - expected_code: 200 - expected_result: '{ "Attributes": { "BootTypeOrder0": "HardDiskDrive", "BootTypeOrder1": - "DVDROMDrive", "BootTypeOrder2": "PXE", "BootTypeOrder3": - "Others", }}' - group: remote interface management - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios -- case_name: configure boot order - case_sn: 40 - expected_code: 200 - expected_result: '{ "Attributes": { "BootTypeOrder0": "DVDROMDrive", "BootTypeOrder1": - "HardDiskDrive", "BootTypeOrder2": "Others", "BootTypeOrder3": - "PXE", }}' - group: remote interface management - header: null - method: PATCH - request_body: '{ "Attributes": { "BootTypeOrder0": "DVDROMDrive", "BootTypeOrder1": - "HardDiskDrive", "BootTypeOrder2": "Others", "BootTypeOrder3": - "PXE", }}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings -- case_name: check boot order - case_sn: 41 - expected_code: 200 - expected_result: '{ "Attributes": { "BootTypeOrder0": "DVDROMDrive", "BootTypeOrder1": - "HardDiskDrive", "BootTypeOrder2": "Others", "BootTypeOrder3": - "PXE", }}' - group: remote interface management - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios -- case_name: configure new boot PXE order first - case_sn: 42 - expected_code: 200 - expected_result: '{ "Attributes": { "BootTypeOrder0": "PXE", "BootTypeOrder1": - "HardDiskDrive", "BootTypeOrder2": "DVDROMDrive", "BootTypeOrder3": - "Others", }}' - group: remote interface management - header: null - method: PATCH - request_body: '{ "Attributes": { "BootTypeOrder0": "PXE", "BootTypeOrder1": - "HardDiskDrive", "BootTypeOrder2": "DVDROMDrive", "BootTypeOrder3": - "Others", }}' - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings -- case_name: check boot order PEX order first - case_sn: 43 - expected_code: 200 - expected_result: '{ "Attributes": { "BootTypeOrder0": "PXE", "BootTypeOrder1": - "HardDiskDrive", "BootTypeOrder2": "DVDROMDrive", "BootTypeOrder3": - "Others", }}' - group: remote interface management - header: null - method: GET - request_body: null - url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios -- case_name: check BMC Firmware version - case_sn: 44 - expected_code: 200 - expected_result: '{"count": 1, "FirmwareVersion": "1.30.11P01 HDM V100R001B03D011SP01"}' - group: remote interface management - header: null - method: GET - request_body: null - url: https://{bmc_ip}{manager_id} -- case_name: change BMC account - case_sn: 45 - expected_code: 200 - expected_result: '{"UserName": "CM_cc@1234","RoleId": "Administrator",}' - group: remote interface management - header: null - method: PATCH - request_body: '{"UserName": "CM_cc@1234","Password": "1234@CM_cc","RoleId": "Administrator",}' - url: https://{bmc_ip}/redfish/v1/AccountService/Accounts/3 -- case_name: configure BMC ip in static, ipv4 - case_sn: 46 - expected_code: 200 - expected_result: '{"count": 1, "IPv4Addresses": [ { "Address": - "192.168.66.120", "AddressOrigin": "Static", "Gateway": - "192.168.66.1", "SubnetMask": "255.255.255.128" } ]}' - group: remote interface management - header: null - method: PATCH - request_body: '{ "IPv4Addresses": [ { "Address": "192.168.66.120", "AddressOrigin": - "Static", "Gateway": "192.168.66.1", "SubnetMask": "255.255.255.128" } ]}' - url: https://{bmc_ip}{manager_id}/EthernetInterfaces/eth1 -- case_name: configure BMC ip in DHCP, gateway and subnet mask ipv4 - case_sn: 47 - expected_code: 200 - expected_result: '{"count": 1, "IPv4Addresses": [ { "Address": - "192.168.66.120", "AddressOrigin": "DHCP", "Gateway": "192.168.66.1", "SubnetMask": - "255.255.255.128" } ]}' - group: remote interface management - header: null - method: PATCH - request_body: '{ "IPv4Addresses": [ { "AddressOrigin": "DHCP" } ]}' - url: https://{bmc_ip}{manager_id}/EthernetInterfaces/eth1 -- case_name: configure BMC ip in static, ipv4 - case_sn: 48 - expected_code: 200 - expected_result: '{"count": 1, "IPv4Addresses": [ { "AddressOrigin": - "DHCP", } ]}' - group: remote interface management - header: null - method: PATCH - request_body: '{ "IPv4Addresses": [ { "AddressOrigin": "DHCP" } ]}' - url: https://{bmc_ip}{manager_id}/EthernetInterfaces/eth1 -- case_name: configure BMC ip in static, ipv6 - case_sn: 49 - expected_code: 200 - expected_result: '{"count": 1, "IPv6Addresses": [ { "Address": - "N/A", "AddressOrigin": "N/A", "PrefixLength": 64 }, { "Address": - "2019::11", "AddressOrigin": "Static", "PrefixLength": 64 } ]}' - group: remote interface management - header: null - method: PATCH - request_body: '{ "IPv6Addresses": [ { "Address": "2019::11", "AddressOrigin": - "Static", "PrefixLength": 64 } ]}' - url: https://{bmc_ip}{manager_id}/EthernetInterfaces/eth1 + url: /redfish/v1/Systems/{system_id}/Memory/{memory_id} + key_flag_dict: {"system_id" : "Members", "memory_id" : "Members"} + +# - case_name: check raid card amount +# case_sn: 15 +# expected_code: 200 +# expected_result: '{"Members@odata.count": 1}' +# group: compoment management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Storages +# - case_name: check raid card information +# case_sn: 16 +# expected_code: 200 +# expected_result: '{ "count": 1, "StorageControllers": [ { "FirmwareVersion": +# "2.62", "Manufacturer": "H3C", "Model": "N/A", "Status": +# { "Health": "OK", "State": "Enabled" } } ]}' +# group: compoment management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}{storage_id} +# - case_name: check harddisk information +# case_sn: 17 +# expected_code: 200 +# expected_result: '{ "count": 4, "CapacityBytes": [480102187008, 960193626112], "Location": +# { "Info": "N/A", "InfoFormat": "DeviceName" }, "Manufacturer": +# "ATA", "MediaType": "SSD", "Model": ["INTEL SSDSC2KB48", "INTEL SSDSC2KB96"], "Protocol": +# "SATA", "Status": { "Health": "OK", "State": "Enabled" }}' +# group: compoment management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}{drives_id} +# - case_name: check network interface adapter information +# case_sn: 18 +# expected_code: 200 +# expected_result: '{ "count": 3, "Manufacturer": "Mellanox", "Model": "NIC-620F-B2-25Gb-2P-1-X", "Name": +# ["PCIeSlot2", "PCIeSlot3", "PCIeSlot6"], "Oem": { "Public": { "CardModel": +# "2*25GE", "RootBDF": ["0000:17:00.0", "0000:17:02.0", "0000:AE:02.0"], } }, "Status": +# { "Health": "OK", "State": "Enabled" }}' +# group: compoment management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}{networkadapters_id} +# - case_name: check network interface adapter port information +# case_sn: 19 +# expected_code: 200 +# expected_result: '{ "count": 6, "AssociatedNetworkAddresses": [ "N/A" ], "Oem": +# { "Public": { "BDF": "N/A", "PortType": "OpticalPort" } }, "PhysicalPortNumber": +# ["1", "2"]}' +# group: compoment management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}{networkports_id} +# - case_name: check fans information +# case_sn: 20 +# expected_code: 200 +# expected_result: '{ "FanSummary": { "Count": 6 }, "Fans": [ { "MemberId": +# "N/A", "Oem": { "Public": { "SpeedRatio": +# "N/A" } }, "Status": { "Health": +# "OK", "State": "Enabled" } }, { "MemberId": +# "N/A", "Oem": { "Public": { "SpeedRatio": +# "N/A" } }, "Status": { "Health": +# "OK", "State": "Enabled" } },{ "MemberId": +# "N/A", "Oem": { "Public": { "SpeedRatio": +# "N/A" } }, "Status": { "Health": +# "OK", "State": "Enabled" } },{ "MemberId": +# "N/A", "Oem": { "Public": { "SpeedRatio": +# "N/A" } }, "Status": { "Health": +# "OK", "State": "Enabled" } },{ "MemberId": +# "N/A", "Oem": { "Public": { "SpeedRatio": +# "N/A" } }, "Status": { "Health": +# "OK", "State": "Enabled" } },{ "MemberId": +# "N/A", "Oem": { "Public": { "SpeedRatio": +# "N/A" } }, "Status": { "Health": +# "OK", "State": "Enabled" } } ],}' +# group: compoment management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id}/Thermal +# - case_name: check power amount +# case_sn: 21 +# expected_code: 200 +# expected_result: '{ "DeviceMaxNum": { "PowerSupplyNum": 2},}' +# group: compoment management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id} +# - case_name: check power detail info +# case_sn: 22 +# expected_code: 200 +# expected_result: '{ "PowerControl": [ { "PowerConsumedWatts": +# "N/A","Status":{ "Health": "OK", "State": "Enabled" } }, ], "PowerSupplies": +# [ { "LineInputVoltage": "N/A", "MemberId": "1", "PowerCapacityWatts": +# 800,"Status": { "Health": "OK", "State": "Enabled" } }, { "LineInputVoltage": +# "N/A", "MemberId": "2", "PowerCapacityWatts": 800,"Status": +# { "Health": "OK", "State": "Enabled" } } ],}' +# group: compoment management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id}/Power +# - case_name: check logical dirve health status +# case_sn: 23 +# expected_code: 200 +# expected_result: '{ "count": 2, "Name": "N/A", "Status": { "Health": +# ["OK", "Critical"], "State": "Enabled" }}' +# group: compoment management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}{volume_id} +# - case_name: check server temperature air intake +# case_sn: 24 +# expected_code: 200 +# expected_result: '{ "Temperatures": [ { "Name": "INPUT_TEMP", "ReadingCelsius": +# "N/A", } ]}' +# group: sensor management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id}/Thermal +# - case_name: check cpu temperature +# case_sn: 25 +# expected_code: 200 +# expected_result: '{ "Temperatures": [ { "Name": "INPUT_TEMP", "ReadingCelsius": +# "N/A", }, { "Name": "CPU1_TEMP", "ReadingCelsius": +# "N/A", }, { "Name": "CPU2_TEMP", "ReadingCelsius": +# "N/A", }, ]}' +# group: sensor management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Chassis/{chassis_id}/Thermal +# - case_name: check server power state +# case_sn: 26 +# expected_code: 200 +# expected_result: '{"PowerState": "On"}' +# group: power management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id} +# - case_name: remote power on server +# case_sn: 27 +# expected_code: 200 +# expected_result: '{"error":{"@Message.ExtendedInfo": [{"Message": "Successfully +# Completed Request", "Severity":"OK"}]}}' +# group: power management +# header: null +# method: POST +# request_body: '{"ResetType": "On"}' +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Actions/ComputerSystem.Reset +# - case_name: remote power off server +# case_sn: 28 +# expected_code: 200 +# expected_result: '{"error":{"@Message.ExtendedInfo": [{"Message": "Successfully +# Completed Request", "Severity":"OK"}]}}' +# group: power management +# header: null +# method: POST +# request_body: '{"ResetType": "GracefulShutdown"}' +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Actions/ComputerSystem.Reset +# - case_name: remote reset server +# case_sn: 29 +# expected_code: 200 +# expected_result: '{"error":{"@Message.ExtendedInfo": [{"Message": "Successfully +# Completed Request", "Severity":"OK"}]}}' +# group: power management +# header: null +# method: POST +# request_body: '{"ResetType": "ForceRestart"}' +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Actions/ComputerSystem.Reset +# - case_name: remote configure CPU in hyperthreading disabled +# case_sn: 30 +# expected_code: 200 +# expected_result: '{"Attributes": {"ProcessorHyperThreading": "Disabled"}}' +# group: remote configure +# header: null +# method: PATCH +# request_body: '{ "Attributes": { "ProcessorHyperThreading": "Disabled" }}' +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings +# - case_name: remote get CPU hyperthreading in disabled +# case_sn: 31 +# expected_code: 200 +# expected_result: '{"Attributes": {"ProcessorHyperThreading": "Disabled"}}' +# group: remote configure +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios +# - case_name: remote configure CPU in hyperthreading enabled +# case_sn: 32 +# expected_code: 200 +# expected_result: '{"Attributes": {"ProcessorHyperThreading": "Enabled"}}' +# group: remote configure +# header: null +# method: PATCH +# request_body: '{ "Attributes": { "ProcessorHyperThreading": "Enabled" }}' +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings +# - case_name: remote get CPU hyperthreading in enabled +# case_sn: 33 +# expected_code: 200 +# expected_result: '{"Attributes": {"ProcessorHyperThreading": "Enabled"}}' +# group: remote configure +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios +# - case_name: disable PXE mode +# case_sn: 34 +# expected_code: 200 +# expected_result: '{ "Attributes": { "IPv4PXESupport": "Disabled" }}' +# group: remote configure +# header: null +# method: PATCH +# request_body: '{ "Attributes": { "IPv4PXESupport": "Disabled" }}' +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings +# - case_name: check IPV4 PXE mode in disabled +# case_sn: 35 +# expected_code: 200 +# expected_result: '{ "Attributes": { "IPv4PXESupport": "Disabled" }}' +# group: remote configure +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios +# - case_name: enable PXE mode +# case_sn: 36 +# expected_code: 200 +# expected_result: '{ "Attributes": { "IPv4PXESupport": "Enabled" }}' +# group: remote configure +# header: null +# method: PATCH +# request_body: '{ "Attributes": { "IPv4PXESupport": "Enabled" }}' +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings +# - case_name: check ipv4 PXE mode in enabled +# case_sn: 37 +# expected_code: 200 +# expected_result: '{ "Attributes": { "IPv4PXESupport": "Enabled" }}' +# group: remote configure +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios +# - case_name: set boot type order +# case_sn: 38 +# expected_code: 200 +# expected_result: '{ "Attributes": { "BootTypeOrder0": "HardDiskDrive", "BootTypeOrder1": +# "DVDROMDrive", "BootTypeOrder2": "PXE", "BootTypeOrder3": +# "Others", }}' +# group: remote interface management +# header: null +# method: PATCH +# request_body: '{ "Attributes": { "BootTypeOrder0": "HardDiskDrive", "BootTypeOrder1": +# "DVDROMDrive", "BootTypeOrder2": "PXE", "BootTypeOrder3": +# "Others", }}' +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings +# - case_name: check boot order +# case_sn: 39 +# expected_code: 200 +# expected_result: '{ "Attributes": { "BootTypeOrder0": "HardDiskDrive", "BootTypeOrder1": +# "DVDROMDrive", "BootTypeOrder2": "PXE", "BootTypeOrder3": +# "Others", }}' +# group: remote interface management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios +# - case_name: configure boot order +# case_sn: 40 +# expected_code: 200 +# expected_result: '{ "Attributes": { "BootTypeOrder0": "DVDROMDrive", "BootTypeOrder1": +# "HardDiskDrive", "BootTypeOrder2": "Others", "BootTypeOrder3": +# "PXE", }}' +# group: remote interface management +# header: null +# method: PATCH +# request_body: '{ "Attributes": { "BootTypeOrder0": "DVDROMDrive", "BootTypeOrder1": +# "HardDiskDrive", "BootTypeOrder2": "Others", "BootTypeOrder3": +# "PXE", }}' +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings +# - case_name: check boot order +# case_sn: 41 +# expected_code: 200 +# expected_result: '{ "Attributes": { "BootTypeOrder0": "DVDROMDrive", "BootTypeOrder1": +# "HardDiskDrive", "BootTypeOrder2": "Others", "BootTypeOrder3": +# "PXE", }}' +# group: remote interface management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios +# - case_name: configure new boot PXE order first +# case_sn: 42 +# expected_code: 200 +# expected_result: '{ "Attributes": { "BootTypeOrder0": "PXE", "BootTypeOrder1": +# "HardDiskDrive", "BootTypeOrder2": "DVDROMDrive", "BootTypeOrder3": +# "Others", }}' +# group: remote interface management +# header: null +# method: PATCH +# request_body: '{ "Attributes": { "BootTypeOrder0": "PXE", "BootTypeOrder1": +# "HardDiskDrive", "BootTypeOrder2": "DVDROMDrive", "BootTypeOrder3": +# "Others", }}' +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios/Settings +# - case_name: check boot order PEX order first +# case_sn: 43 +# expected_code: 200 +# expected_result: '{ "Attributes": { "BootTypeOrder0": "PXE", "BootTypeOrder1": +# "HardDiskDrive", "BootTypeOrder2": "DVDROMDrive", "BootTypeOrder3": +# "Others", }}' +# group: remote interface management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}/redfish/v1/Systems/{system_id}/Bios +# - case_name: check BMC Firmware version +# case_sn: 44 +# expected_code: 200 +# expected_result: '{"count": 1, "FirmwareVersion": "1.30.11P01 HDM V100R001B03D011SP01"}' +# group: remote interface management +# header: null +# method: GET +# request_body: null +# url: https://{bmc_ip}{manager_id} +# - case_name: change BMC account +# case_sn: 45 +# expected_code: 200 +# expected_result: '{"UserName": "CM_cc@1234","RoleId": "Administrator",}' +# group: remote interface management +# header: null +# method: PATCH +# request_body: '{"UserName": "CM_cc@1234","Password": "1234@CM_cc","RoleId": "Administrator",}' +# url: https://{bmc_ip}/redfish/v1/AccountService/Accounts/3 +# - case_name: configure BMC ip in static, ipv4 +# case_sn: 46 +# expected_code: 200 +# expected_result: '{"count": 1, "IPv4Addresses": [ { "Address": +# "192.168.66.120", "AddressOrigin": "Static", "Gateway": +# "192.168.66.1", "SubnetMask": "255.255.255.128" } ]}' +# group: remote interface management +# header: null +# method: PATCH +# request_body: '{ "IPv4Addresses": [ { "Address": "192.168.66.120", "AddressOrigin": +# "Static", "Gateway": "192.168.66.1", "SubnetMask": "255.255.255.128" } ]}' +# url: https://{bmc_ip}{manager_id}/EthernetInterfaces/eth1 +# - case_name: configure BMC ip in DHCP, gateway and subnet mask ipv4 +# case_sn: 47 +# expected_code: 200 +# expected_result: '{"count": 1, "IPv4Addresses": [ { "Address": +# "192.168.66.120", "AddressOrigin": "DHCP", "Gateway": "192.168.66.1", "SubnetMask": +# "255.255.255.128" } ]}' +# group: remote interface management +# header: null +# method: PATCH +# request_body: '{ "IPv4Addresses": [ { "AddressOrigin": "DHCP" } ]}' +# url: https://{bmc_ip}{manager_id}/EthernetInterfaces/eth1 +# - case_name: configure BMC ip in static, ipv4 +# case_sn: 48 +# expected_code: 200 +# expected_result: '{"count": 1, "IPv4Addresses": [ { "AddressOrigin": +# "DHCP", } ]}' +# group: remote interface management +# header: null +# method: PATCH +# request_body: '{ "IPv4Addresses": [ { "AddressOrigin": "DHCP" } ]}' +# url: https://{bmc_ip}{manager_id}/EthernetInterfaces/eth1 +# - case_name: configure BMC ip in static, ipv6 +# case_sn: 49 +# expected_code: 200 +# expected_result: '{"count": 1, "IPv6Addresses": [ { "Address": +# "N/A", "AddressOrigin": "N/A", "PrefixLength": 64 }, { "Address": +# "2019::11", "AddressOrigin": "Static", "PrefixLength": 64 } ]}' +# group: remote interface management +# header: null +# method: PATCH +# request_body: '{ "IPv6Addresses": [ { "Address": "2019::11", "AddressOrigin": +# "Static", "PrefixLength": 64 } ]}' +# url: https://{bmc_ip}{manager_id}/EthernetInterfaces/eth1 |