summaryrefslogtreecommitdiffstats
path: root/src/collectd-ceilometer-plugin
ModeNameSize
-rw-r--r--Makefile1612logstatsplain
n90'>90 91 92 93 94 95 96 97 98 99 100 101 102 103 104 105 106 107 108 109 110 111 112 113 114 115 116 117 118 119 120 121 122 123 124 125 126 127 128 129 130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 161 162 163 164 165 166 167 168 169 170 171 172 173 174 175 176 177 178 179 180 181 182 183 184 185 186 187 188 189 190 191 192 193 194 195 196 197 198 199 200 201 202 203 204 205 206 207 208 209 210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 242 243 244 245 246 247 248 249 250 251 252 253 254 255 256 257 258 259 260 261 262 263 264 265 266 267 268 269 270 271 272 273 274 275 276 277 278 279 280 281 282 283 284 285 286 287 288 289 290 291 292 293 294 295 296 297 298 299 300 301 302 303 304 305 306 307 308 309 310 311 312 313 314 315 316 317 318 319 320 321 322 323 324 325 326 327 328 329 330 331 332 333 334 335 336 337 338 339 340 341 342 343 344 345 346 347 348 349 350 351 352 353 354 355 356 357 358 359 360 361 362 363 364 365 366 367 368 369 370 371 372 373 374 375 376 377 378 379 380 381 382 383 384 385 386 387 388 389 390 391 392 393 394 395 396 397 398 399 400 401 402 403 404 405 406 407 408 409 410 411 412 413 414 415 416 417 418 419 420 421 422 423 424 425 426 427 428 429 430 431 432 433 434 435 436 437 438 439 440 441 442 443 444 445 446 447 448 449 450 451 452 453 454 455 456 457 458 459 460 461 462 463 464 465 466 467 468 469 470 471 472 473 474 475 476 477 478 479 480 481 482 483 484 485 486 487 488 489 490 491 492 493 494 495 496 497 498 499 500 501 502 503 504 505 506 507 508 509 510 511 512 513 514 515 516 517 518 519 520 521 522 523 524 525 526 527 528 529 530 531 532 533 534 535 536 537 538 539 540 541 542 543 544 545 546 547 548 549 550 551 552 553 554 555 556 557 558 559 560 561 562 563 564 565 566 567 568 569 570 571 572 573 574 575 576 577 578 579 580 581 582 583 584 585 586 587 588 589 590 591 592 593 594 595 596 597 598 599 600 601 602 603 604 605 606 607 608 609 610 611 612 613 614 615 616 617 618 619 620 621 622 623 624 625 626 627 628 629 630 631 632 633 634 635 636 637 638 639 640 641 642 643 644 645 646 647 648 649 650 651 652 653 654 655 656 657 658 659 660 661 662 663 664 665 666 667 668 669 670 671 672 673 674 675
#
# NFVbench default configuration file
#
# This configuration file is ALWAYS loaded by NFVbench and should never be modified by users.
# To specify your own property values, always define them in a separate config file
# and pass that file to the script using -c or --config <file>
# Property values in that config file will override the default values in the current file
#
---
# IMPORTANT CUSTOMIZATION NOTES
# There are roughly 2 types of NFVbench config based on the OpenStack encaps used:
# - VLAN (OVS, OVS-DPDK, ML2/VPP)
# Many of the fields to customize are relevant to only 1 of the 2 encaps
# These will be clearly labeled "VxLAN only" or "VLAN only"
# Fields that are not applicable will not be used by NFVbench and can be left empty
#
# All fields are applicable to all encaps/traffic generators unless explicitly marked otherwise.
# Fields that can be over-ridden at the command line are marked with the corresponding
# option, e.g. "--interval"


# The OpenStack openrc file to use - must be a valid full pathname. If running
# in a container, this path must be valid in the container.
#
# The only case where this field can be empty is when measuring a system that does not run
# OpenStack or when OpenStack APIs are not accessible or OpenStack APis use is not
# desirable. In that case the EXT service chain must be used.
#
# If openrc is not admin some parameters are mandatory and must be filled with valid values in config file such as :
# - availability_zone
# - hypervisor_hostname
# - vlans
openrc_file:

# Forwarder to use in nfvbenchvm image. Available options: ['vpp', 'testpmd']
vm_forwarder: testpmd

# By default (empty) NFVbench will try to locate a VM image file
# from the package root directory named "nfvbench-<version>.qcow2" and
# upload that file. The image name will be "nfvbench-<version>"
# This can be overridden by specifying here a pathname of a file
# that follows the same naming convention.
# In most cases, this field should be left empty as the packaging should
# include the proper VM image file
vm_image_file:

# Name of the flavor to use for the loopback VMs
#
# If the provided name is an exact match to a flavor name known by OpenStack
# (as shown from 'nova flavor-list'), that flavor will be reused.
# Otherwise, a new flavor will be created with attributes listed below.
flavor_type: 'nfvbench.medium'

# Custom flavor attributes for the test VM
flavor:
  # Number of vCPUs for the flavor, must be at least 2!
  vcpus: 2
  # Memory for the flavor in MB
  ram: 4096
  # Size of local disk in GB
  disk: 0
  # metadata are supported and can be added if needed, optional
  # note that if your openstack does not have NUMA optimization
  # (cpu pinning and huge pages)
  # you must comment out extra_specs completely otherwise
  # loopback VM creation will fail
  extra_specs:
      "hw:cpu_policy": dedicated
      "hw:mem_page_size": large

# Enable multiqueue for all test VM interfaces (PVP and PVVP only).
# When enabled, the test VM image will get added the property to enable
# multiqueue (hw_vif_multiqueue_enabled='true').
# The number of queues per interace will be set to the number of vCPUs configured for
# the VM.
# By default there is only 1 queue per interface
# The max allowed queue per interface is 8.
# The valid range for this parameter is [1..min(8, vcpu_count)]
# When multiqueue is used the recommended setting is to set it to same value as the
# number of vCPU used - up to a max of 8 queues.
# Setting to a lower value than vCPU should also work. For example if using 4 vCPU and
# vif_multiqueue_size is set to 2, openstack will create 4 queues per interface but the
# test VM will only use the first 2 queues.
vif_multiqueue_size: 1

# Name of the availability zone to use for the test VMs
# Must be one of the zones listed by 'nova availability-zone-list'
# availability_zone: 'nova'
# If openrc is not admin set a valid value
availability_zone:
# To force placement on a given hypervisor, set the name here
# (if multiple names are provided, the first will be used)
# Leave empty to let openstack pick the hypervisor
compute_nodes:
# If openrc is not admin set a valid value for hypervisor hostname
# Example of value: hypervisor_hostname: "server1"
hypervisor_hostname:

# Type of service chain to run, possible options are PVP, PVVP and EXT
# PVP - port to VM to port
# PVVP - port to VM to VM to port
# EXT - external chain used only for running traffic and checking traffic generator counters,
#       all other parts of chain must be configured manually
# Can be overriden by --service-chain
service_chain: 'PVP'

# Total number of service chains, every chain has own traffic stream
# Can be overriden by --service-chain-count
service_chain_count: 1

# Specifies if all chains share the same right/left/middle networks
service_chain_shared_net: false

# Total number of traffic flows for all chains and directions generated by the traffic generator.
# Minimum is '2 * service_chain_count', it is automatically adjusted if too small
# value was configured. Must be even.
# Every flow has packets with different IPs in headers
# Can be overriden by --flow-count
flow_count: 10000

# set to true if service chains should use SRIOV
# This requires SRIOV to be available on compute nodes
sriov: false

# Perform port to port loopback (direct or through switch)
# Should be used with EXT service chain and no ARP (no_arp: true)
# When enabled, the vlans property must contain the same VLAN id for all chains.
# Can be overriden by --l2-loopback
l2_loopback: false

# Resources created by NFVbench will not be removed
# Can be overriden by --no-cleanup
no_cleanup: false

# Configuration for traffic generator
traffic_generator:
    # Name of the traffic generator, only for informational purposes
    host_name: 'nfvbench_tg'
    # this is the default traffic generator profile to use
    # the name must be defined under generator_profile
    # you can override the traffic generator to use using the
    # -g or --traffic-gen option at the command line
    default_profile: trex-local

    # IP addresses for L3 traffic.
    # This section describes the addresses to use to fill in the UDP packets sent by the
    # traffic generator. If you VNFs are L2 forwarders, these fields below do not need to change.
    # If your VNFs are L3 routers, the fields below must match the static routes in your VNFs
    # so that UDP packets can be routed back to the peer port of the traffic generator.

    # All of the IPs are used as base for IP sequence computed based on chain or flow count.
    # (sim-devices-left)---(tg-gateway-left)---(vnf-left)- ...
    #                                      -(vnf-right)---(tg-gateway-right)---(sim-devices-right)
    #
    # `ip_addrs` base IPs used as src and dst in packet header, quantity depends on flow count
    #            these are used for addressing virtual devices simulated by the traffic generator
    #            and be a different subnet than tg_gateway_ip_addrs and gateway_ip_addrs
    # `ip_addrs_step`: step for generating IP sequence. Use "random" for random patterns, default is 0.0.0.1.
    ip_addrs: ['10.0.0.0/8', '20.0.0.0/8']
    ip_addrs_step: 0.0.0.1
    # `tg_gateway_ip_addrs` base IP for traffic generator ports in the left and right networks to the VNFs
    #                       chain count consecutive IP addresses spaced by tg_gateway_ip_addrs_step will be used
    # `tg_gateway_ip_addrs__step`: step for generating traffic generator gateway sequences. default is 0.0.0.1
    tg_gateway_ip_addrs: ['1.1.0.100', '2.2.0.100']
    tg_gateway_ip_cidrs: ['1.1.0.0/24','2.2.0.0/24']
    tg_gateway_ip_addrs_step: 0.0.0.1
    # `gateway_ip_addrs`: base IPs of VNF router gateways (left and right), quantity used depends on chain count
    #                     must correspond to the public IP on the left and right networks
    #                     for each left-most and right-most VNF of every chain.
    #                     must be the same subnet but not same IP as tg_gateway_ip_addrs.
    #                     chain count consecutive IP addresses spaced by gateway_ip_addrs_step will be used
    # `gateway_ip_addrs_step`: step for generating router gateway sequences. default is 0.0.0.1
    gateway_ip_addrs: ['1.1.0.2', '2.2.0.2']
    gateway_ip_addrs_step: 0.0.0.1
    # `udp_src_port`: the source port for sending UDP traffic, default is picked by TRex (53)
    # `udp_dst_port`: the destination port for sending UDP traffic, default is picked by TRex (53)
    udp_src_port:
    udp_dst_port:

    # VxLAN only: optionally specify what VLAN tag to use for the VxLAN overlay
    # This is used if the vxlan tunnels are running on a specific VLAN.
    # Leave empty if there is no VLAN tagging required, or specify the VLAN id to use
    # for all VxLAN tunneled traffic
    vtep_vlan:
    # VxLAN only: local/source vteps IP addresses for port 0 and 1 ['10.1.1.230', '10.1.1.231']
    src_vteps:
    # VxLAN only: remote IP address of the remote VTEPs that terminate all tunnels originating from local VTEPs
    dst_vtep:

    # L2 ADDRESSING OF UDP PACKETS
    # Lists of dest MAC addresses to use on each traffic generator port (one dest MAC per chain)
    # Leave empty for PVP, PVVP, EXT with ARP
    # Only used when `service_chain` is EXT and `no_arp` is true.
    #   - If both lists are empty the far end MAC of the traffic generator will be used for left and right
    #     (this is typicaly used to loop back on the first hop switch or using a loopback cable)
    #   - The length of each list must match the number of chains being used!
    #   - The index of each list must correspond to the chain index to ensure proper pairing.
    #   - Below is an example of using two chains:
    #     - mac_addrs_left: ['00:00:00:00:01:00', '00:00:00:00:02:00']
    #     - mac_addrs_right: ['00:00:00:00:01:01', '00:00:00:00:02:01']
    #     UDP packets sent on port 0 will use dest MAC '00:00:00:00:01:00' for chain #0 and
    #                                         dest MAC '00:00:00:00:02:00' for chain #1
    #     UDP packets sent on port 1 will use dest MAC '00:00:00:00:01:01' for chain #0 and
    #                                         dest MAC '00:00:00:00:02:01' for chain #1
    #     It is expected that the looping device (L2 forwarder) will rewrite the src and dst MAC
    #     of the looping UDP packet so that it can reach back to the peer port of the traffic
    #     generator.
    #
    mac_addrs_left:
    mac_addrs_right:

    # Traffic Generator Profiles
    # In case you have multiple testbeds or traffic generators,
    # you can define one traffic generator profile per testbed/traffic generator.
    # In most cases you only need to fill in the pci address for the 2 ports used by the
    # traffic generator and leave all other fields unchanged
    #
    # Generator profiles are listed in the following format:
    # `name`: Traffic generator profile name (use a unique name, no space or special character)
    #         Do not change this field
    # `tool`: Traffic generator tool to be used (currently supported is `TRex`).
    #         Do not change this field
    # `ip`: IP address of the traffic generator.
    #       The default loopback address is used when the traffic generator runs on the same host
    #       as NFVbench.
    # `cores`: Specify the number of cores for running the TRex traffic generator.
    #          ONLY applies to trex-local.
    # `software_mode`: Advice TRex to use software mode which provides the best compability. But
    #                  note that TRex will not use any hardware acceleration technology under
    #                  software mode, therefore the performance of TRex will be significantly
    #                  lower. ONLY applies to trex-local.
    #                  Recommended to leave the default value (false)
    # `limit_memory`: Specify the memory reserved for running the TRex traffic generator (in MB). Limit the amount
    #                 of packet memory used. (Passed to dpdk as -m arg)
    #          ONLY applies to trex-local.
    # `zmq_pub_port`: Specify the ZMQ pub port number for the TRex traffic generator instance (default value is 4500).
    #          ONLY applies to trex-local.
    # `zmq_rpc_port`: Specify the ZMQ rpc port for the TRex traffic generator instance (default value is 4501).
    #          ONLY applies to trex-local.
    # `interfaces`: Configuration of traffic generator interfaces.
    # `interfaces.port`: The port of the traffic generator to be used (leave as 0 and 1 resp.)
    # `interfaces.switch_port`: Leave empty (deprecated)
    # `interfaces.pci`: The PCI address of the intel NIC interface associated to this port
    #                   This field is required and cannot be empty
    #                   Use lspci to list the PCI address of all devices
    #                   Example of value: "0000:5e:00.0"
    # `intf_speed`: The speed of the interfaces used by the traffic generator (per direction).
    #               Empty value (default) to use the speed discovered by the traffic generator.
    #               Recommended to leave this field empty.
    #               Do not use unless you want to override the speed discovered by the
    #               traffic generator. Expected format: 10Gbps
    #
    # `platform`: Optional. Used to tune the performance and allocate the cores to the right NUMA.
    #             See https://trex-tgn.cisco.com/trex/doc/trex_manual.html (6.2.3. Platform section configuration)
    #             for more details
    # `platform.master_thread_id`: Hardware thread_id for control thread. (Valid value is mandatory if platform property is set)
    # `platform.latency_thread_id`: Hardware thread_id for RX thread. (Valid value is mandatory if platform property is set)
    # `platform.dual_if`: Section defines info for interface pairs (according to the order in “interfaces” list). (Valid value is mandatory if platform property is set)
    #                     Each section, starting with “- socket” defines info for different interface pair. (Valid value is mandatory if platform property is set)
    # `platform.dual_if.socket`: The NUMA node from which memory will be allocated for use by the interface pair. (Valid value is mandatory if platform property is set)
    # `platform.dual_if.threads`: Hardware threads to be used for sending packets for the interface pair. (Valid value is mandatory if platform property is set)
    #                     Threads are pinned to cores, so specifying threads actually determines the hardware cores.
    # Example of values:
    # platform:
    #   master_thread_id: 0
    #   latency_thread_id: 2
    #   dual_if:
    #     - socket: 0
    #       threads: [1]
    #
    generator_profile:
        - name: trex-local
          tool: TRex
          ip: 127.0.0.1
          cores: 4
          software_mode: false
          limit_memory: 1024
          zmq_pub_port: 4500
          zmq_rpc_port: 4501
          interfaces:
            - port: 0
              pci:
              switch_port:
            - port: 1
              pci:
              switch_port:
          intf_speed:
          platform:
            master_thread_id:
            latency_thread_id:
            dual_if:
              - socket:
                threads:

# Use 'true' to force restart of local TRex server before next run
# TRex local server will be restarted even if restart property is false in case of generator config changes between runs
restart: false

# Simpler override for trex core count and mbuf multilier factor
# if empty defaults to the one specified in generator_profile.cores
cores:

# mbuffer ratio to use for TRex (see TRex documentation for more details)
mbuf_factor: 0.2

# -----------------------------------------------------------------------------
# These variables are not likely to be changed

# Number of seconds to wait for VMs to pass traffic in both directions
check_traffic_time_sec: 200

# General retry count
generic_retry_count: 100

# General poll period
generic_poll_sec: 2

# name of the loop VM
loop_vm_name: 'nfvbench-loop-vm'

# Default names, subnets and CIDRs for PVP/PVVP networks (openstack only)
#
# If a network with given name already exists it will be reused.
# - PVP only uses left and right
# - PVVP uses left, middle and right
# - for EXT chains, this structure is not relevant - refer to external_networks
# Otherwise a new internal network will be created with that name, subnet and CIDR.
#
# network_type must be 'vlan' (for VLAN and SRIOV) or 'vxlan' (for VxLAN)
#              all 3 networks must use the same network type in this release
# segmentation_id can be set to enforce a specific segmentation id (vlan ID or VNI if vxlan)
#                 by default (empty) the segmentation id will be assigned by Neutron.
#                 If specified, it must be unique for each network
#                 For multi-chaining, see notes below
# physical_network can be set to pick a specific phsyical network - by default (empty) the
#                   default physical network will be picked
# SR-IOV: both physical_network and VLAN segmentation ID must be provided
# VxLAN: the VNI must generally be provided (except special Neutron VxLAN implementations)
#
# For example to setup 1xPVP using 2 different SR-IOV ports, you must put the appropriate physnet
# names under left.physical_network and right.physical_network.
# For multi-chaining and non shared networks,
# Example of override configuration to force PVP to run on 2 SRIOV ports (phys_sriov0 and phys_sriov1)
# using VLAN ID 2000 and 2001:
# internal_networks:
#    left:
#        segmentation_id: 2000
#        physical_network: phys_sriov0
#    right:
#        segmentation_id: 2001
#        physical_network: phys_sriov1
#
# For multi-chaining and non shared network mode (VLAN, SRIOV, VxLAN):
# - the segmentation_id field if provided must be a list of values (as many as chains)
# - segmentation_id auto-indexing:
#   the segmentation_id field can also be a single value that represents the base value from which
#   values for each chain is derived using the chain ID as an offset. For example
#   if 2000 is specified, NFVbench will use 2000 for chain 0, 2001 for chain 1 etc...
#   The ranges of all the networks must not overlap.
# - the physical_network can be a single name (all VFs to be allocated on same physnet)
#   of a list of physnet names to use different PFs
#
# Example of 2-chain configuration:
# internal_networks:
#    left:
#        segmentation_id: [2000, 2001]
#        physical_network: phys_sriov0
#    right:
#        segmentation_id: [2010, 2011]
#        physical_network: phys_sriov1
#
# Equivalent to (using auto-indexing):
# internal_networks:
#    left:
#        segmentation_id: 2000
#        physical_network: phys_sriov0
#    right:
#        segmentation_id: 2010
#        physical_network: phys_sriov1

internal_networks:
    left:
        name: 'nfvbench-lnet'
        subnet: 'nfvbench-lsubnet'
        cidr: '192.168.1.0/24'
        network_type: 'vlan'
        segmentation_id:
        physical_network:
    right:
        name: 'nfvbench-rnet'
        subnet: 'nfvbench-rsubnet'
        cidr: '192.168.2.0/24'
        network_type: 'vlan'
        segmentation_id:
        physical_network:
    middle:
        name: 'nfvbench-mnet'
        subnet: 'nfvbench-msubnet'
        cidr: '192.168.3.0/24'
        network_type: 'vlan'
        segmentation_id:
        physical_network:

# IDLE INTERFACES: PVP, PVVP and non shared net only.
# By default each test VM will have 2 virtual interfaces for looping traffic.
# If service_chain_shared_net is false, additional virtual interfaces can be
# added at VM creation time, these interfaces will not carry any traffic and
# can be used to test the impact of idle interfaces in the overall performance.
# All these idle interfaces will use normal ports (not direct).
# Number of idle interfaces per VM (none by default)
idle_interfaces_per_vm: 0

# A new network is created for each idle interface.
# If service_chain_shared_net is true, the options below will be ignored
# and no idle interfaces will be added.
idle_networks:
    # Prefix for all idle networks, the final name will append the chain ID and idle index
    # e.g. "nfvbench-idle-net.0.4" chain 0 idle index 4
    name: 'nfvbench-idle-net'
    # Subnet name to use for all idle subnetworks 
    subnet: 'nfvbench-idle-subnet'
    # CIDR to use for all idle networks (value should not matter)
    cidr: '192.169.1.0/24'
    # Type of network associated to the idle virtual interfaces (vlan or vxlan)
    network_type: 'vlan'
    # segmentation ID to use for the network attached to the idle virtual interfaces
    # vlan: leave empty to let neutron pick the segmentation ID
    # vxlan: must specify the starting VNI value to be used (cannot be empty)
    # Note that NFVbench will use as many consecutive segmentation IDs as needed.
    # For example, for 4 PVP chains and 8 idle
    # interfaces per VM, NFVbench will use 32 consecutive values of segmentation ID
    # starting from the value provided.
    segmentation_id:
    # physnet name to use for all idle interfaces
    physical_network:

# In the scenario of PVVP + SRIOV, there is choice of how the traffic will be
# handled in the middle network. The default (false) will use vswitch, while
# SRIOV can be used by toggling below setting.
use_sriov_middle_net: false

# EXT chain only. Prefix names of edge networks or list of edge network names
# used to send traffic via traffic generator.
#
# If service_chain_shared_net is true, the left and right networks must pre-exist and match exactly by name.
#
# If service_chain_shared_net is false, each chain must have its own pre-existing left and right networks.
# left and right can take either a string prefix or a list of arbitrary network names
# If a string prefix is passed, an index will be appended to each network name to form the final name.
# Example:
# external_networks:
#    left:  'ext-lnet'
#    right: 'ext-rnet'
# ext-lnet0 ext-rnet0 for chain #0
# ext-lnet1 ext-rnet1 for chain #1
# etc...
# If a list of strings is passed, each string in the list must be the name of the network used for the
# chain indexed by the entry position in the list.
# The list must have at least as many entries as there are chains
# Example:
# external_networks:
#   left:  ['ext-lnet', 'ext-lnet2']
#   right: ['ext-rnet', 'ext-rnet2']
# 
external_networks:
    left:
    right:

# PVP with L3 router in the packet path only.
# Only use when l3_router option is True (see l3_router)
# Prefix names of edge networks which will be used to send traffic via traffic generator.
# If a network with given name already exists it will be reused.
# Otherwise a new edge network will be created with that name, subnet and CIDR.
#
# gateway can be set in case of L3 traffic with edge networks - refer to edge_networks
#
# segmentation_id can be set to enforce a specific VLAN id - by default (empty) the VLAN id
#                 will be assigned by Neutron.
#                 Must be unique for each network
# physical_network can be set to pick a specific phsyical network - by default (empty) the
#                   default physical network will be picked
#
edge_networks:
    left:
        name: 'nfvbench-net2'
        router_name: 'router_left'
        subnet: 'nfvbench-subnet2'
        cidr: '192.168.3.0/24'
        gateway:
        network_type:
        segmentation_id:
        physical_network:
    right:
        name: 'nfvbench-net3'
        router_name: 'router_right'
        subnet: 'nfvbench-subnet3'
        cidr: '192.168.4.0/24'
        gateway:
        network_type:
        segmentation_id:
        physical_network:

# Use 'true' to enable VXLAN encapsulation support and sent by the traffic generator
# When this option enabled internal networks 'network type' parameter value should be 'vxlan'
vxlan: false

# Use 'true' to enable VLAN tagging of packets generated and sent by the traffic generator
# Leave empty or set to false if you do not want the traffic generator to insert the VLAN tag (this is
# needed for example if VLAN tagging is enabled on switch (access mode) or if you want to hook
# directly to a NIC).
# By default is set to true (which is the nominal use case with TOR and trunk mode to Trex ports)
# If VxLAN is enabled, this option should be set to false (vlan tagging for encapsulated packets
# is not supported). Use the vtep_vlan option to enable vlan tagging for the VxLAN overlay network.
vlan_tagging: true

# Used only in the case of EXT chain and no openstack or not admin access to specify the VLAN IDs to use.
# This property is ignored when OpenStakc is used or in the case of l2-loopback.
# If OpenStack is used leave the list empty, VLAN IDs are retrieved from OpenStack networks using Neutron API.
# If networks are shared across all chains (service_chain_shared_net=true), the list should have exactly 2 values
# If networks are not shared across chains (service_chain_shared_net=false), the list should have
# 2 list of vlan IDs
# In the special case of l2-loopback the list should have the same VLAN id for all chains
# Examples:
#   [1998, 1999] left network uses vlan 1998 right network uses vlan 1999
#   [[1,2],[3,4]] chain 0 left vlan 1, right vlan 2 - chain 1 left vlan 3 right vlan 4
#   [1010, 1010] same VLAN id with l2-loopback enabled
#
vlans: []

# ARP is used to discover the MAC address of VNFs that run L3 routing.
# Used only with EXT chain.
# False (default): ARP requests are sent to find out dest MAC addresses.
# True: do not send ARP but use provisioned dest macs instead
#       (see mac_addrs_left and mac_addrs_right)
no_arp: false

# Traffic Profiles
# You can add here more profiles as needed
# `l2frame_size` can be specified in any none zero integer value to represent the size in bytes
# of the L2 frame, or "IMIX" to represent the standard 3-packet size mixed sequence (IMIX1).
traffic_profile:
    - name: traffic_profile_64B
      l2frame_size: ['64']
    - name: traffic_profile_IMIX
      l2frame_size: ['IMIX']
    - name: traffic_profile_1518B
      l2frame_size: ['1518']
    - name: traffic_profile_3sizes
      l2frame_size: ['64', 'IMIX', '1518']

# Traffic Configuration
# bidirectional: to have traffic generated from both direction, set bidirectional to true
# profile: must be one of the profiles defined in traffic_profile
# The traffic profile can be overriden with the options --frame-size and --uni-dir
traffic:
    bidirectional: true
    profile: traffic_profile_64B

# Check config and connectivity only - do not generate traffic
# Can be overriden by --no-traffic
no_traffic: false

# Use an L3 router in the packet path. This option if set will create or reuse an openstack neutron
# router (PVP, PVVP) or reuse an existing L3 router (EXT) to route traffic to the destination VM.
# Can be overriden by --l3-router
l3_router: false

# Test configuration

# The rate pps for traffic going in reverse direction in case of unidirectional flow. Default to 1.
unidir_reverse_traffic_pps: 1

# The rate specifies if NFVbench should determine the NDR/PDR
#  or if NFVbench should just generate traffic at a given fixed rate
# for a given duration (called "single run" mode)
# Supported rate format:
# NDR/PDR test: `ndr`, `pdr`, `ndr_pdr` (default)
# Or for single run mode:
# Packet per second: pps (e.g. `50pps`)
# Bits per second: bps, kbps, Mbps, etc (e.g. `1Gbps`, `1000bps`)
# Load percentage: % (e.g. `50%`)
# Can be overridden by --rate
rate: ndr_pdr

# Default run duration (single run at given rate only)
# Can be overridden by --duration
duration_sec: 60

# Interval between intermediate reports when interval reporting is enabled
# Can be overridden by --interval
interval_sec: 10

# Default pause between iterations of a binary search (NDR/PDR)
pause_sec: 2

# NDR / PDR configuration
measurement:
    # Drop rates represent the ratio of dropped packet to the total number of packets sent.
    # Values provided here are percentages. A value of 0.01 means that at most 0.01% of all
    # packets sent are dropped (or 1 packet every 10,000 packets sent)

    # No Drop Rate in percentage; Default to 0.001%
    NDR: 0.001
    # Partial Drop Rate in percentage; NDR should always be less than PDR
    PDR: 0.1
    # The accuracy of NDR and PDR as a percnetage of line rate; The exact NDR
    # or PDR should be within `load_epsilon` line rate % from the one calculated.
    # For example, with a value 0.1, and a line rate of 10Gbps, the accuracy
    # of NDR and PDR will be within 0.1% Of 10Gbps or 10Mbps.
    # The lower the value the more iterations and the longer it will take to find the NDR/PDR.
    # In practice, due to the precision of the traffic generator it is not recommended to
    # set it to lower than 0.1
    load_epsilon: 0.1

# Location where to store results in a JSON format. Must be container specific path.
# Can be overriden by --json
json:

# Location where to store results in the NFVbench standard JSON format:
# <service-chain-type>-<service-chain-count>-<flow-count>-<packet-sizes>.json
# Example: PVP-1-10-64-IMIX.json
# Must be container specific path.
# Can be overriden by --std-json
std_json:

# Prints debug messages (verbose mode)
# Can be overriden by --debug
debug: false

# Set to a valid path name if logging to file is to be enabled
# Defaults to disabled
log_file:

# When enabled, all results and/or logs will be sent to a fluentd servers at the requested IPs and ports
# A list of one or more fluentd servers identified by their IPs and  port numbers should be given.
# For each recipient it is possible to enable both sending logs and performance
# results, or enable either logs or performance results. For enabling logs or results logging_tag or
# result_tag should be set.

fluentd:
      # by default (logging_tag is empty) nfvbench log messages are not sent to fluentd
      # to enable logging to fluents, specify a valid fluentd tag name to be used for the
      # log records
    - logging_tag:

      # by default (result_tag is empty) nfvbench results are not sent to fluentd
      # to enable sending nfvbench results to fluentd, specify a valid fluentd tag name
      # to be used for the results records, which is different than logging_tag
      result_tag:

      # IP address of the server, defaults to loopback
      ip: 127.0.0.1

      # port # to use, by default, use the default fluentd forward port
      port: 24224

      # by default (logging_tag is empty) nfvbench log messages are not sent to fluentd
      # to enable logging to fluents, specify a valid fluentd tag name to be used for the
      # log records

# Module and class name of factory which will be used to provide classes dynamically for other components.
factory_module: 'nfvbench.factory'
factory_class: 'BasicFactory'

# Custom label added for every perf record generated during this run.
# Can be overriden by --user-label
user_label:


# THESE FIELDS SHOULD BE USED VERY RARELY

# Skip vswitch configuration and retrieving of stats
# Can be overriden by --no-vswitch-access
# Should be left to the default value (false)
no_vswitch_access: false