aboutsummaryrefslogtreecommitdiffstats
path: root/src/fuel-plugin
diff options
context:
space:
mode:
authorGuo Ruijing <ruijing.guo@intel.com>2017-01-23 12:58:12 -0500
committerGuo Ruijing <ruijing.guo@intel.com>2017-01-23 13:00:39 -0500
commit44e0a4a6936352d9f09592074117eb043b83c617 (patch)
tree06fc2d50a932ef0b0401a8dfe38b2a1d60e7e563 /src/fuel-plugin
parent882a58174574b12f67c42129828f113dd717eebd (diff)
fuel: Update the fuel README.md & metadata
Change-Id: I82c1ab08603cd288a717c294fceabd230c691706 Signed-off-by: Maryam Tahhan <maryam.tahhan@intel.com> Signed-off-by: Guo Ruijing <ruijing.guo@intel.com>
Diffstat (limited to 'src/fuel-plugin')
-rw-r--r--src/fuel-plugin/README.md17
-rw-r--r--src/fuel-plugin/metadata.yaml4
2 files changed, 12 insertions, 9 deletions
diff --git a/src/fuel-plugin/README.md b/src/fuel-plugin/README.md
index 0a44a9c0..d7491977 100644
--- a/src/fuel-plugin/README.md
+++ b/src/fuel-plugin/README.md
@@ -1,5 +1,5 @@
-plugin-collectd-ceilometer
-=========================
+Barometer Plugin
+================
Plugin description
Installs collectd-ceilometer on compute via a fuel plugin.
@@ -30,10 +30,10 @@ step 1, 2, 3 may be bypassed if fuel plugin is installed from /opt/opnfv in fuel
2) build plugin
fpb --build <plugin-dir>
- e.g.: fpb --build fastpathmetrics/src/fuel-plugin
+ e.g.: fpb --build barometer/src/fuel-plugin
3) copy plugin rpm to fuel master
- e.g. scp fuel-plugin-collectd-ceilometer-0.9-0.9.0-1.noarch.rpm <user>@<server-name>:~/
+ e.g. scp fuel-plugin-collectd-ceilometer-1.0-1.0.0-1.noarch.rpm <user>@<server-name>:~/
4) install plugin
fuel plugins --install <plugin-name>.rpm
@@ -41,10 +41,10 @@ step 1, 2, 3 may be bypassed if fuel plugin is installed from /opt/opnfv in fuel
5) prepare fuel environment
a) enable ceilometer service
go to settings/openstack services
- enable ceilometer plugin with checkbox
+ check 'Install Ceilometer and Aodh' to enable ceilometer
b) enable collectd-ceilometer
go to settings/other
- enable collectd-ceilometer plugin with checkbox
+ enable the barometer plugins using the checkboxes
c) save settings
6) add nodes to environment
@@ -54,4 +54,7 @@ step 1, 2, 3 may be bypassed if fuel plugin is installed from /opt/opnfv in fuel
8) verify
SSH to openstack controller node:
source openrc
- ceilometer sample-list --meter interface.if_packets
+ ceilometer sample-list -m interface.if_packets
+ ceilometer sample-list -m hugepages.vmpage_number
+ ceilometer sample-list -m ovs_events.gauge
+ ceilometer sample-list -m mcelog.errors
diff --git a/src/fuel-plugin/metadata.yaml b/src/fuel-plugin/metadata.yaml
index 0d4f8f6f..376e7dc8 100644
--- a/src/fuel-plugin/metadata.yaml
+++ b/src/fuel-plugin/metadata.yaml
@@ -1,11 +1,11 @@
# Plugin name
name: fuel-plugin-collectd-ceilometer
# Human-readable name for your plugin
-title: Deploy Collectd Ceilometer Plugin
+title: Barometer Plugin
# Plugin version
version: '1.0.0'
# Description
-description: Deploy Collectd Ceilometer Plugin
+description: Deploy Barometer Plugin
# Required fuel version
fuel_version: ['10.0']
# Specify license of your plugin