diff options
author | Maria Toeroe <Maria.Toeroe@ericsson.com> | 2015-10-15 12:40:46 -0400 |
---|---|---|
committer | Maria Toeroe <Maria.Toeroe@ericsson.com> | 2015-10-15 12:40:46 -0400 |
commit | d83377be15dcc9a5e52299cd268baad3782f729b (patch) | |
tree | 43817eaaea383b178d43c8b85536299233874614 | |
parent | cfc9794d7917e2520b84f46b5a392e63124d25fd (diff) |
Introduction to the HA Use Cases
Add use basic cases
Modify based on comments. Size figures
Remove slide figures
Add updated figures
Apply modifications suggested by Ian
Apply Ian's suggestions and other small fixes
Add conclusion and fix spelling
JIRA: HA-11 HA-14
Change-Id: I04331a4fd25d95a69ac086c962399ce6c49c8c33
Signed-off-by: Maria Toeroe <Maria.Toeroe@ericsson.com>
20 files changed, 731 insertions, 0 deletions
diff --git a/UseCases/UseCases.rst b/UseCases/UseCases.rst new file mode 100644 index 0000000..57dfbc0 --- /dev/null +++ b/UseCases/UseCases.rst @@ -0,0 +1,731 @@ +============ +HA Use Cases +============ + +************** +1 Introduction +************** + +This use case document outlines the model and failure modes for NFV systems. Its goal is along +with the requirements documents and gap analysis help set context for engagement with various +upstream projects. The OPNFV HA project team continuously evolving these documents, and in +particular this use case document starting with a set of basic use cases. + +***************** +2 Basic Use Cases +***************** + + +In this section we review some of the basic use cases related to service high availability, +that is, the availability of the service or function provided by a VNF. The goal is to +understand the different scenarios that need to be considered and the specific requirements +to provide service high availability. More complex use cases will be discussed in +other sections. + +With respect to service high availability we need to consider whether a VNF implementation is +statefull or stateless and if it includes or not an HA manager which handles redundancy. +For statefull VNFs we can also distinguish the cases when the state is maintained inside +of the VNF or it is stored in an external shared storage making the VNF itself virtually +stateless. + +Managing availability usually implies a fault detection mechanism, which triggers the +actions necessary for fault isolation followed by the recovery from the fault. +This recovery includes two parts: + +* the recovery of the service and +* the repair of the failed entity. + +Very often the recovery of the service and the repair actions are perceived to be the same, for +example, restarting a failed application repairs the application, which then provides the service again. +Such a restart may take significant time causing service outage, for which redundancy is the solution. +In cases when the service is protected by redundancy of the providing entities (e.g. application +processes), the service is "failed over" to the standby or a spare entity, which replaces the +failed entity while it is being repaired. E.g. when an application process providing the service fails, +the standby application process takes over providing the service, while the failed one is restarted. +Such a failover often allows for faster recovery of the service. + +We also need to distinguish between the failed and the faulty entities as a fault may or +may not manifest in the entity containing the fault. Faults may propagate, i.e. cause other entities +to fail or misbehave, i.e. an error, which in turn might be detected by a different failure or +error detector entity each of which has its own scope. Similarly, the managers acting on these +detected errors may have a limited scope. E.g. an HA manager contained in a VNF can only repair +entities within the VNF. It cannot repair a failed VM, in fact due to the layered architecture +in the VNF it cannot even know whether the VM failed, its hosting hypervisor, or the physical host. +But its error detection mechanism will detect the result of such failures - a failure in the VNF - +and the service can be recovered at the VNF level. +On the other hand, the failure should be detected in the NFVI and the VIM should repair the failed +entity (e.g. the VM). Accordingly a failure may be detected by different managers in different layers +of the system, each of which may react to the event. This may cause interference. +Thus, to resolve the problem in a consistent manner and completely recover from +a failure the managers may need to collaborate and coordinate their actions. + +Considering all these issues the following basic use cases can be identified (see table 1.). +These use cases assume that the failure is detected in the faulty entity (VNF component +or the VM). + + +*Table 1: VNF high availability use cases* + ++---------+-------------------+----------------+-------------------+----------+ +| | VNF Statefullness | VNF Redundancy | Failure detection | Use Case | ++=========+===================+================+===================+==========+ +| VNF | yes | yes | VNF level only | UC1 | +| | | +-------------------+----------+ +| | | | VNF & NFVI levels | UC2 | +| | +----------------+-------------------+----------+ +| | | no | VNF level only | UC3 | +| | | +-------------------+----------+ +| | | | VNF & NFVI levels | UC4 | +| +-------------------+----------------+-------------------+----------+ +| | no | yes | VNF level only | UC5 | +| | | +-------------------+----------+ +| | | | VNF & NFVI levels | UC6 | +| | +----------------+-------------------+----------+ +| | | no | VNF level only | UC7 | +| | | +-------------------+----------+ +| | | | VNF & NFVI levels | UC8 | ++---------+-------------------+----------------+-------------------+----------+ + +As discussed, there is no guarantee that a fault manifests within the faulty entity. For +example, a memory leak in one process may impact or even crash any other process running in +the same execution environment. Accordingly, the repair of a failing entity (i.e. the crashed process) +may not resolve the problem and soon the same or another process may fail within this execution +environment indicating that the fault has remained in the system. +Thus, there is a need for extrapolating the failure to a wider scope and perform the +recovery at that level to get rid of the problem (at least temporarily till a patch is available +for our leaking process). +This requires the correlation of repeated failures in a wider scope and the escalation of the +recovery action to this wider scope. In the layered architecture this means that the manager detecting the +failure may not be the one in charge of the scope at which it can be resolved, so the escalation needs to +be forwarded to the manager in charge of that scope, which brings us to an additional use case UC9. + +We need to consider for each of these use cases the events detected, their impact on other entities, +and the actions triggered to recover the service provided by the VNF, and to repair the +faulty entity. + +We are going to describe each of the listed use cases from this perspective to better +understand how the problem of service high availability can be tackled the best. + +Before getting into the details it is worth mentioning the example end-to-end service recovery +times provided in the ETSI NFV REL document [REL]_ (see table 2.). These values may change over time +including lowering these thresholds. + +*Table 2: Service availability levels (SAL)* + ++----+---------------+----------------------+------------------------------------+ +|SAL |Service |Customer Type | Recommendation | +| |Recovery | | | +| |Time | | | +| |Threshold | | | ++====+===============+======================+====================================+ +|1 |5 - 6 seconds |Network Operator |Redundant resources to be | +| | |Control Traffic |made available on-site to | +| | | |ensure fastrecovery. | +| | |Government/Regulatory | | +| | |Emergency Services | | ++----+---------------+----------------------+------------------------------------+ +|2 |10 - 15 seconds|Enterprise and/or |Redundant resources to be available | +| | |large scale customers |as a mix of on-site and off-site | +| | | |as appropriate: On-site resources to| +| | |Network Operators |be utilized for recovery of | +| | |service traffic |real-time service; Off-site | +| | | |resources to be utilized for | +| | | |recovery of data services | ++----+---------------+----------------------+------------------------------------+ +|3 |20 - 25 seconds|General Consumer |Redundant resources to be mostly | +| | |Public and ISP |available off-site. Real-time | +| | |Traffic |services should be recovered before | +| | | |data services | ++----+---------------+----------------------+------------------------------------+ + +Note that even though SAL 1 of [REL]_ allows for 5-6 seconds of service recovery, +for many services this is too long and such outage causes a service level reset or +the loss of significant amount of data. Also the end-to-end service or network service +may be served by multiple VNFs. Therefore for a single VNF the desired +service recovery time is sub-second. + +Note that failing over the service to another provider entity implies the redirection of the traffic +flow the VNF is handling. This could be achieved in different ways ranging from floating IP addresses +to load balancers. The topic deserves its own investigation, therefore in these first set of +use cases we assume that it is part of the solution without going into the details, which +we will address as a complementary set of use cases. + +.. [REL] ETSI GS NFV-REL 001 V1.1.1 (2015-01) + + +2.1 Use Case 1: VNFC failure in a statefull VNF with redundancy +============================================================== + +Use case 1 represents a statefull VNF with redundancy managed by an HA manager, +which is part of the VNF (Fig 1). The VNF consists of VNFC1, VNFC2 and the HA Manager. +The latter managing the two VNFCs, e.g. the role they play in providing the service +named "Provided NF" (Fig 2). + +The failure happens in one of the VNFCs and it is detected and handled by the HA manager. +On practice the HA manager could be part of the VNFC implementations or it could +be a separate entity in the VNF. The point is that the communication of these +entities inside the VNF is not visible to the rest of the system. The observable +events need to cross the boundary represented by the VNF box. + + +.. figure:: images/Slide4.png + :alt: VNFC failure in a statefull VNF + :figclass: align-center + + Fig 1. VNFC failure in a statefull VNF with built-in HA manager + + +.. figure:: images/StatefullVNF-VNFCfailure.png + :alt: MSC of the VNFC failure in a statefull VNF + :figclass: align-center + + Fig 2. Sequence of events for use case 1 + + +As shown in Fig 2. initially VNFC2 is active, i.e. provides the Provided NF and VNFC1 +is a standby. It is not shown, but it is expected that VNFC1 has some means to get the update +of the state of the Provided NF from the active VNFC2, so that it is prepared to continue to +provide the service in case VNFC2 fails. +The sequence of events starts with the failure of VNFC2, which also interrupts the +Provided NF. This failure is detected somehow and/or reported to the HA Manager, which +in turn may report the failure to the VNFM and simultaneously it tries to isolate the +fault by cleaning up VNFC2. + +Once the cleanup succeeds (i.e. the OK is received) it fails over the active role to +VNFC1 by setting it active. This recovers the service, the Provided NF is indeed +provided again. Thus this point marks the end of the outage caused by the failure +that need to be considered from the perspective of service availability. + +The repair of the failed VNFC2, which might have started at the same time +when VNFC1 was assigned the active state, may take longer but without further impact +on the availability of the Provided NF service. +If the HA Manager reported the interruption of the Provided NF to the VNFM, it should +clear the error condition. + +The key points in this scenario are: + +* The failure of the VNFC2 is not detectable by any other part of the system except + the consumer of the Provided NF. The VNFM only + knows about the failure because of the error report, and only the information this + report provides. I.e. it may or may not include the information on what failed. +* The Provided NF is resumed as soon as VNFC1 is assigned active regardless how long + it takes to repair VNFC2. +* The HA manager could be part of the VNFM as well. This requires an interface to + detect the failures and to manage the VNFC life-cycle and the role assignments. + +2.2 Use Case 2: VM failure in a statefull VNF with redundacy +============================================================ + +Use case 2 also represents a statefull VNF with its redundancy managed by an HA manager, +which is part of the VNF. The VNFCs of the VNF are hosted on the VMs provided by +the NFVI (Fig 3). + +The VNF consists of VNFC1, VNFC2 and the HA Manager (Fig 4). The latter managing +the role the VNFCs play in providing the service - Provided NF. +The VMs provided by the NFVI are managed by the VIM. + + +In this use case it is one of the VMs hosting the VNF fails. The failure is detected +and handled at both the NFVI and the VNF levels simultaneously. The coordination occurs +between the VIM and the VNFM. + + +.. figure:: images/Slide6.png + :alt: VM failure in a statefull VNF + :figclass: align-center + + Fig 3. VM failure in a statefull VNF with built-in HA manager + + +.. figure:: images/StatefullVNF-VMfailure.png + :alt: MSC of the VM failure in a statefull VNF + :figclass: align-center + + Fig 4. Sequence of events for use case 2 + + +Again initially VNFC2 is active and provides the Provided NF, while VNFC1 is the standby. +It is not shown in Fig 4., but it is expected that VNFC1 has some means to learn the state +of the Provided NF from the active VNFC2, so that it is able to continue providing the +service if VNFC2 fails. VNFC1 is hosted on VM1, while VNFC2 is hosted on VM2 as indicated by +the arrows between these objects in Fig 4. + +The sequence of events starts with the failure of VM2, which results in VNFC2 failing and +interrupting the Provided NF. The HA Manager detects the failure of VNFC2 somehow +and tries to handle it the same way as in use case 1. However because the VM is gone the +clean up either not initiated at all or interrupted as soon as the failure of the VM is +identified. In either case the faulty VNFC2 is considered as isolated. + +To recover the service the HA Manager fails over the active role to VNFC1 by setting it active. +This recovers the Provided NF. Thus this point marks again the end of the outage caused +by the VM failure that need to be considered from the perspective of service availability. +If the HA Manager reported the interruption of the Provided NF to the VNFM, it should +clear the error condition. + +On the other hand the failure of the VM is also detected in the NFVI and reported to the VIM. +The VIM reports the VM failure to the VNFM, which passes on this information +to the HA Manager of the VNF. This confirms for the VNF HA Manager the VM failure and that +it needs to wait with the repair of the failed VNFC2 until the VM is provided again. The +VNFM also confirms towards the VIM that it is safe to restart the VM. + +The repair of the failed VM may take some time, but since the service has been failed over +to VNFC1 in the VNF, there is no further impact on the availability of Provided NF. + +When eventually VM2 is restarted the VIM reports this to the VNFM and +the VNFC2 can be restored. + +The key points in this scenario are: + +* The failure of the VM2 is detectable at both levels VNF and NFVI, therefore both the HA + manager and the VIM reacts to it. It is essential that these reactions do not interfere, + e.g. if the VIM tries to protect the VM state at NFVI level that would conflict with the + service failover action at the VNF level. +* While the failure detection happens at both NFVI and VNF levels, the time frame within + which the VIM and the HA manager detect and react may be very different. For service + availability the VNF level detection, i.e. by the HA manager is the critical one and expected + to be faster. +* The Provided NF is resumed as soon as VNFC1 is assigned active regardless how long + it takes to repair VM2 and VNFC2. +* The HA manager could be part of the VNFM as well. + This requires an interface to detect failures in/of the VNFC and to manage its life-cycle and + role assignments. +* The VNFM may not know for sure that the VM failed until the VIM reports it, i.e. whether + the VM failure is due to host, hypervisor, host OS failure. Thus the VIM should report/alarm + and log VM, hypervisor, and physical host failures. The use cases for these failures + are similar with respect to the Provided NF. +* The VM repair also should start with the fault isolation as appropriate for the actual + failed entity, e.g. if the VM failed due to a host failure a host may be fenced first. +* The negotiation between the VNFM and the VIM may be replaced by configured repair actions. + E.g. on error restart VM in initial state, restart VM from last snapshot, or fail VM over to standby. + + +2.3 Use Case 3: VNFC failure in a statefull VNF with no redundancy +================================================================= + +Use case 3 also represents a statefull VNF, but it stores its state externally on a +virtual disk provided by the NFVI. It has a single VNFC and it is managed by the VNFM +(Fig 5). + +In this use case the VNFC fails and the failure is detected and handled by the VNFM. + + +.. figure:: images/Slide10.png + :alt: VNFC failure in a statefull VNF No-Red + :figclass: align-center + + Fig 5. VNFC failure in a statefull VNF with no redundancy + + +.. figure:: images/StatefullVNF-VNFCfailureNoRed.png + :alt: MSC of the VNFC failure in a statefull VNF No-Red + :figclass: align-center + + Fig 6. Sequence of events for use case 3 + + +The VNFC periodically checkpoints the state of the Provided NF to the external storage, +so that in case of failure the Provided NF can be resumed (Fig 6). + +When the VNFC fails the Provided NF is interrupted. The failure is detected by the VNFM +somehow, which to isolate the fault first cleans up the VNFC, then if the cleanup is +successful it restarts the VNFC. When the VNFC starts up, first it reads the last checkpoint +for the Provided NF, then resumes providing it. The service outage lasts from the VNFC failure +till this moment. + +The key points in this scenario are: + +* The service state is saved in an external storage which should be highly available too to + protect the service. +* The NFVI should provide this guarantee and also that storage and access network failures + are handled seemlessly from the VNF's perspective. +* The VNFM has means to detect VNFC failures and manage its life-cycle appropriately. This is + not required if the VNF also provides its availability management. +* The Provided NF can be resumed only after the VNFC is restarted and it has restored the + service state from the last checkpoint created before the failure. +* Having a spare VNFC can speed up the service recovery. This requires that the VNFM coordinates + the role each VNFC takes with respect to the Provided NF. I.e. the VNFCs do not act on the + stored state simultaneously potentially interfering and corrupting it. + + + +2.4 Use Case 4: VM failure in a statefull VNF with no redundancy +=============================================================== + +Use case 4 also represents a statefull VNF without redundancy, which stores its state externally on a +virtual disk provided by the NFVI. It has a single VNFC managed by the VNFM +(Fig 7) as in use case 3. + +In this use case the VM hosting the VNFC fails and the failure is detected and handled by +the VNFM and the VIM simultaneously. + + +.. figure:: images/Slide11.png + :alt: VM failure in a statefull VNF No-Red + :figclass: align-center + + Fig 7. VM failure in a statefull VNF with no redundancy + +.. figure:: images/StatefullVNF-VMfailureNoRed.png + :alt: MSC of the VM failure in a statefull VNF No-Red + :figclass: align-center + + Fig 8. Sequence of events for use case 4 + +Again, the VNFC regularly checkpoints the state of the Provided NF to the external storage, +so that it can be resumed in case of a failure (Fig 8). + +When the VM hosting the VNFC fails the Provided NF is interrupted. + +On the one hand side, the failure is detected by the VNFM somehow, which to isolate the fault tries +to clean the VNFC up which cannot be done because of the VM failure. When the absence of the VM has been +determined the VNFM has to wait with restarting the VNFC until the hosting VM is restored. The VNFM +may report the problem to the VIM, requesting a repair. + +On the other hand the failure is detected in the NFVI and reported to the VIM, which reports it +to the VNFM, if the VNFM hasn't reported it yet. +If the VNFM has requested the VM repair or if it acknowledges the repair, the VIM restarts the VM. +Once the VM is up the VIM reports it to the VNFM, which in turn can restart the VNFC. + +When the VNFC restarts first it reads the last checkpoint for the Provided NF, +to be able to resume it. +The service outage last until this is recovery completed. + +The key points in this scenario are: + + +* The service state is saved in external storage which should be highly available to + protect the service. +* The NFVI should provide such a guarantee and also that storage and access network failures + are handled seemlessly from the perspective of the VNF. +* The Provided NF can be resumed only after the VM and the VNFC are restarted and the VNFC + has restored the service state from the last checkpoint created before the failure. +* The VNFM has means to detect VNFC failures and manage its life-cycle appropriately. Alternatively + the VNF may also provide its availability management. +* The VNFM may not know for sure that the VM failed until the VIM reports this. It also cannot + distinguish host, hypervisor and host OS failures. Thus the VIM should report/alarm and log + VM, hypervisor, and physical host failures. The use cases for these failures are + similar with respect to the Provided NF. +* The VM repair also should start with the fault isolation as appropriate for the actual + failed entity, e.g. if the VM failed due to a host failure a host may be fenced first. +* The negotiation between the VNFM and the VIM may be replaced by configured repair actions. +* VM level redundancy, i.e. running a standby or spare VM in the NFVI would allow faster service + recovery for this use case, but by itself it may not protect against VNFC level failures. I.e. + VNFC level error detection is still required. + + + +2.5 Use Case 5: VNFC failure in a stateless VNF with redundancy +=============================================================== + +Use case 5 represents a stateless VNF with redundancy, i.e. it is composed of VNFC1 and VNFC2. +They are managed by an HA manager within the VNF. The HA manager assigns the active role to provide +the Provided NF to one of the VNFCs while the other remains a spare meaning that it has no state +information for the Provided NF (Fig 9) therefore it could replace any other VNFC capable of +providing the Provided NF service. + +In this use case the VNFC fails and the failure is detected and handled by the HA manager. + + +.. figure:: images/Slide13.png + :alt: VNFC failure in a stateless VNF with redundancy + :figclass: align-center + + Fig 9. VNFC failure in a stateless VNF with redundancy + + +.. figure:: images/StatelessVNF-VNFCfailure.png + :alt: MSC of the VNFC failure in a stateless VNF with redundancy + :figclass: align-center + + Fig 10. Sequence of events for use case 5 + + +Initially VNFC2 provides the Provided NF while VNFC1 is idle or might not even been instantiated +yet (Fig 10). + +When VNFC2 fails the Provided NF is interrupted. This failure is detected by the HA manager, +which as a first reaction cleans up VNFC2 (fault isolation), then it assigns the active role to +VNFC1. It may report an error to the VNFM as well. + +Since there is no state information to recover, VNFC1 can accept the active role right away +and resume providing the Provided NF service. Thus the service outage is over. If the HA manager +reported an error to the VNFM it should clear it at this point. + +The key points in this scenario are: + +* The spare VNFC may be instantiated only once the failure of active VNFC is detected. +* As a result the HA manager's role might be limited to life-cycle management, i.e. no role + assignment is needed if the VNFCs provide the service as soon as they are started up. +* Accordingly the HA management could be part of a generic VNFM provided it is capable of detecting + the VNFC failures. Besides the service users, the VNFC failure may not be detectable at any other + part of the system. +* Also there could be multiple active VNFCs sharing the load of Provided NF and the spare/standby + may protect all of them. +* Reporting the service failure to the VNFM is optional as the HA manager is in charge of recovering + the service and it is aware of the redundancy needed to do so. + + +2.6 Use Case 6: VM failure in a stateless VNF with redundancy +============================================================ + + +Similarly to use case 5, use case 6 represents a stateless VNF composed of VNFC1 and VNFC2, +which are managed by an HA manager within the VNF. The HA manager assigns the active role to +provide the Provided NF to one of the VNFCs while the other remains a spare meaning that it has +no state information for the Provided NF (Fig 11) and it could replace any other VNFC capable +of providing the Provided NF service. + +As opposed to use case 5 in this use case the VM hosting one of the VNFCs fails. This failure is +detected and handled by the HA manager as well as the VIM. + + +.. figure:: images/Slide14.png + :alt: VM failure in a stateless VNF with redundancy + :figclass: align-center + + Fig 11. VM failure in a stateless VNF with redundancy + + +.. figure:: images/StatelessVNF-VMfailure.png + :alt: MSC of the VM failure in a stateless VNF with redundancy + :figclass: align-center + + Fig 12. Sequence of events for use case 6 + + +Initially VNFC2 provides the Provided NF while VNFC1 is idle or might not have been instantiated +yet (Fig 12) as in use case 5. + +When VM2 fails VNFC2 fails with it and the Provided NF is interrupted. The failure is detected by +the HA manager and by the VIM simultaneously and independently. + +The HA manager's first reaction is trying to clean up VNFC2 to isolate the fault. This is considered to +be successful as soon as the disappearance of the VM is confirmed. +After this the HA manager assigns the active role to VNFC1. It may report the error to the VNFM as well +requesting a VM repair. + +Since there is no state information to recover, VNFC1 can accept the assignment right away +and resume the Provided NF service. Thus the service outage is over. If the HA manager reported +an error to the VNFM for the service it should clear it at this point. + +Simultaneously the VM failure is detected in the NFVI and reported to the VIM, which reports it +to the VNFM, if the VNFM hasn't requested a repair yet. If the VNFM requested the VM repair or if +it acknowledges the repair, the VIM restarts the VM. + +Once the VM is up the VIM reports it to the VNFM, which in turn may restart the VNFC if needed. + + +The key points in this scenario are: + +* The spare VNFC may be instantiated only after the detection of the failure of the active VNFC. +* As a result the HA manager's role might be limited to life-cycle management, i.e. no role + assignment is needed if the VNFC provides the service as soon as it is started up. +* Accordingly the HA management could be part of a generic VNFM provided if it is capable of detecting + failures in/of the VNFC and managing its life-cycle. +* Also there could be multiple active VNFCs sharing the load of Provided NF and the spare/standby + may protect all of them. +* The VNFM may not know for sure that the VM failed until the VIM reports this. It also cannot + distinguish host, hypervisor and host OS failures. Thus the VIM should report/alarm and log + VM, hypervisor, and physical host failures. The use cases for these failures are + similar with respect to each Provided NF. +* The VM repair also should start with the fault isolation as appropriate for the actual + failed entity, e.g. if the VM failed due to a host failure a host needs to be fenced first. +* The negotiation between the VNFM and the VIM may be replaced by configured repair actions. +* Reporting the service failure to the VNFM is optional as the HA manager is in charge recovering + the service and it is aware of the redundancy needed to do so. + + + +2.7 Use Case 7: VNFC failure in a stateless VNF with no redundancy +================================================================== + +Use case 7 represents a stateless VNF composed of a single VNFC, i.e. with no redundancy. +The VNF and in particular its VNFC is managed by the VNFM through managing its life-cycle (Fig 13). + +In this use case the VNFC fails. This failure is detected and handled by the VNFM. This use case +requires that the VNFM can detect the failures in the VNF or they are reported to the VNFM. + +The failure is only detectable at the VNFM level and it is handled by the VNFM restarting the VNFC. + + +.. figure:: images/Slide16.png + :alt: VNFC failure in a stateless VNF with no redundancy + :figclass: align-center + + Fig 13. VNFC failure in a stateless VNF with no redundancy + + +.. figure:: images/StatelessVNF-VNFCfailureNoRed.png + :alt: MSC of the VNFC failure in a stateless VNF with no redundancy + :figclass: align-center + + Fig 14. Sequence of events for use case 7 + +The VNFC is providing the Provided NF when it fails (Fig 14). This failure is detected or reported to +the VNFM, which has to clean up the VNFC to isolate the fault. After cleanup success it can proceed +with restarting the VNFC, which as soon as it is up it starts to provide the Provided NF +as there is no state to recover. + +Thus the service outage is over, but it has included the entire time needed to restart the VNFC. +Considering that the VNF is stateless this may not be significant still. + + +The key points in this scenario are: + +* The VNFM has to have the means to detect VNFC failures and manage its life-cycle appropriately. + This is not required if the VNF comes with its availability management, but this is very unlikely + for such stateless VNFs. +* The Provided NF can be resumed as soon as the VNFC is restarted, i.e. the restart time determines + the outage. +* In case multiple VNFCs are used they should not interfere with one another, they should + operate independently. + + +2.8 Use Case 8: VM failure in a stateless VNF with no redundancy +================================================================ + +Use case 8 represents the same stateless VNF composed of a single VNFC as use case 7, i.e. with +no redundancy. The VNF and in particular its VNFC is managed by the VNFM through managing its +life-cycle (Fig 15). + +In this use case the VM hosting the VNFC fails. This failure is detected and handled by the VNFM +as well as by the VIM. + + +.. figure:: images/Slide17.png + :alt: VM failure in a stateless VNF with no redundancy + :figclass: align-center + + Fig 15. VM failure in a stateless VNF with no redundancy + + +.. figure:: images/StatelessVNF-VMfailureNoRed.png + :alt: MSC of the VM failure in a stateless VNF with no redundancy + :figclass: align-center + + Fig 16. Sequence of events for use case 8 + +The VNFC is providing the Provided NF when the VM hosting the VNFC fails (Fig 16). + +This failure may be detected or reported to the VNFM as a failure of the VNFC. The VNFM may +not be aware at this point that it is a VM failure. Accordingly its first reaction as in use case 7 +is to clean up the VNFC to isolate the fault. Since the VM is gone, this cannot succeed and the VNFM +becomes aware of the VM failure through this or it is reported by the VIM. In either case it has to wait +with the repair of the VMFC until the VM becomes available again. + +Meanwhile the VIM also detects the VM failure and reports it to the VNFM unless the VNFM has already +requested the VM repair. After the VNFM confirming the VM repair the VIM restarts the VM and reports +the successful repair to the VNFM, which in turn can start the VNFC hosted on it. + + +Thus the recovery of the Provided NF includes the restart time of the VM and of the VNFC. + +The key points in this scenario are: + +* The VNFM has to have the means to detect VNFC failures and manage its life-cycle appropriately. + This is not required if the VNF comes with its availability management, but this is very unlikely + for such stateless VNFs. +* The Provided NF can be resumed only after the VNFC is restarted on the repaired VM, i.e. the + restart time of the VM and the VNFC determines the outage. +* In case multiple VNFCs are used they should not interfere with one another, they should + operate independently. +* The VNFM may not know for sure that the VM failed until the VIM reports this. It also cannot + distinguish host, hypervisor and host OS failures. Thus the VIM should report/alarm and log + VM, hypervisor, and physical host failures. The use cases for these failures are + similar with respect to each Provided NF. +* The VM repair also should start with the fault isolation as appropriate for the actual + failed entity, e.g. if the VM failed due to a host failure the host needs to be fenced first. +* The repair negotiation between the VNFM and the VIM may be replaced by configured repair actions. +* VM level redundancy, i.e. running a standby or spare VM in the NFVI would allow faster service + recovery for this use case, but by itself it may not protect against VNFC level failures. I.e. + VNFC level error detection is still required. + +2.9 Use Case 9: Repeated VNFC failure in a stateless VNF with no redundancy +=========================================================================== + +Finally use case 9 represents again a stateless VNF composed of a single VNFC as in use case 7, i.e. +with no redundancy. The VNF and in particular its VNFC is managed by the VNFM through managing its +life-cycle. + +In this use case the VNFC fails repeatedly. This failure is detected and handled by the VNFM, +but results in no resolution of the fault (Fig 17) because the VNFC is manifesting a fault, +which is not in its scope. I.e. the fault is propagating to the VNFC from a faulty VM or host, +for example. Thus the VNFM cannot resolve the problem by itself. + + +.. figure:: images/Slide19.png + :alt: Repeated VNFC failure in a stateless VNF with no redundancy + :figclass: align-center + + Fig 17. VM failure in a stateless VNF with no redundancy + + +To handle this case the failure handling needs to be escalated to the a bigger fault zone +(or fault domain), i.e. a scope within which the faults may propagate and manifest. In case of the +VNF the bigger fault zone is the VM and the facilities hosting it, all managed by the VIM. + +Thus the VNFM should request the repair from the VIM (Fig 18). + +Since the VNFM is only aware of the VM, it needs to report an error on the VM and it is the +VIM's responsibility to sort out what might be the scope of the actual fault depending on other +failures and error reports in its scope. + + +.. figure:: images/Slide20.png + :alt: Escalation of repeated VNFC failure in a stateless VNF with no redundancy + :figclass: align-center + + Fig 18. VM failure in a stateless VNF with no redundancy + + +.. figure:: images/StatelessVNF-VNFCfailureNoRed-Escalation.png + :alt: MSC of the VM failure in a stateless VNF with no redundancy + :figclass: align-center + + Fig 19. Sequence of events for use case 9 + + +This use case starts similarly to use case 7, i.e. the VNFC is providing the Provided NF when it fails +(Fig 17). +This failure is detected or reported to the VNFM, which cleans up the VNFC to isolate the fault. +After successful cleanup the VNFM proceeds with restarting the VNFC, which as soon as it is up +starts to provide the Provided NF again as in use case 7. + +However the VNFC failure occurs N times repeatedly within some Probation time for which the VNFM starts +the timer when it detects the first failure of the VNFC. When the VNFC fails once more still within the +probation time the Escalation counter maximum is exceeded and the VNFM reports an error to the VIM on +the VM hosting the VNFC as obviously cleaning up and restarting the VNFC did not solve the problem. + +When the VIM receives the error report for the VM it has to isolate the fault by cleaning up at least +the VM. After successful cleanup it can restart the VM and once it is up report the VM repair to the VNFM. +At this point the VNFM can restart the VNFC, which in turn resumes the Provided VM. + +In this scenario the VIM needs to evaluate what may be the scope of the fault to determine what entity +needs a repair. For example, if it has detected VM failures on that same host, or other VNFMs +reported errors on VMs hosted on the same host, it should consider that the entire host needs a repair. + + +The key points in this scenario are: + +* The VNFM has to have the means to detect VNFC failures and manage its life-cycle appropriately. + This is not required if the VNF comes with its availability management, but this is very unlikely + for such stateless VNFs. +* The VNFM needs to correlate VNFC failures over time to be able to detect failure of a bigger fault zone. + One way to do so is through counting the failures within a probation time. +* The VIM cannot detect all failures caused by faults in the entities under its control. It should be + able to receive error reports and correlate these error reports based on the dependencies + of the different entities. +* The VNFM does not know the source of the failure, i.e. the faulty entity. +* The VM repair should start with the fault isolation as appropriate for the actual + failed entity, e.g. if the VM failed due to a host failure the host needs to be fenced first. + +******************** +3 Concluding remarks +******************** + +This use case document outlined the model and some failure modes for NFV systems. These are an +initial list. The OPNFV HA project team is continuing to grow the list of use cases and will +issue additional documents going forward. The basic use cases and service availability considerations +help define the key considerations for each use case taking into account the impact on the end service. +The use case document along with the requirements documents and gap analysis help set context for +engagement with various upstream projects. diff --git a/UseCases/images/Slide10.png b/UseCases/images/Slide10.png Binary files differnew file mode 100644 index 0000000..b3545e8 --- /dev/null +++ b/UseCases/images/Slide10.png diff --git a/UseCases/images/Slide11.png b/UseCases/images/Slide11.png Binary files differnew file mode 100644 index 0000000..3aa5f67 --- /dev/null +++ b/UseCases/images/Slide11.png diff --git a/UseCases/images/Slide13.png b/UseCases/images/Slide13.png Binary files differnew file mode 100644 index 0000000..207c4a7 --- /dev/null +++ b/UseCases/images/Slide13.png diff --git a/UseCases/images/Slide14.png b/UseCases/images/Slide14.png Binary files differnew file mode 100644 index 0000000..e6083c9 --- /dev/null +++ b/UseCases/images/Slide14.png diff --git a/UseCases/images/Slide16.png b/UseCases/images/Slide16.png Binary files differnew file mode 100644 index 0000000..484ffa2 --- /dev/null +++ b/UseCases/images/Slide16.png diff --git a/UseCases/images/Slide17.png b/UseCases/images/Slide17.png Binary files differnew file mode 100644 index 0000000..7240aaa --- /dev/null +++ b/UseCases/images/Slide17.png diff --git a/UseCases/images/Slide19.png b/UseCases/images/Slide19.png Binary files differnew file mode 100644 index 0000000..7e3c10b --- /dev/null +++ b/UseCases/images/Slide19.png diff --git a/UseCases/images/Slide20.png b/UseCases/images/Slide20.png Binary files differnew file mode 100644 index 0000000..2e9759b --- /dev/null +++ b/UseCases/images/Slide20.png diff --git a/UseCases/images/Slide4.png b/UseCases/images/Slide4.png Binary files differnew file mode 100644 index 0000000..a701f42 --- /dev/null +++ b/UseCases/images/Slide4.png diff --git a/UseCases/images/Slide6.png b/UseCases/images/Slide6.png Binary files differnew file mode 100644 index 0000000..04a904f --- /dev/null +++ b/UseCases/images/Slide6.png diff --git a/UseCases/images/StatefullVNF-VMfailure.png b/UseCases/images/StatefullVNF-VMfailure.png Binary files differnew file mode 100644 index 0000000..2f62232 --- /dev/null +++ b/UseCases/images/StatefullVNF-VMfailure.png diff --git a/UseCases/images/StatefullVNF-VMfailureNoRed.png b/UseCases/images/StatefullVNF-VMfailureNoRed.png Binary files differnew file mode 100644 index 0000000..6f3058d --- /dev/null +++ b/UseCases/images/StatefullVNF-VMfailureNoRed.png diff --git a/UseCases/images/StatefullVNF-VNFCfailure.png b/UseCases/images/StatefullVNF-VNFCfailure.png Binary files differnew file mode 100644 index 0000000..9021f2d --- /dev/null +++ b/UseCases/images/StatefullVNF-VNFCfailure.png diff --git a/UseCases/images/StatefullVNF-VNFCfailureNoRed.png b/UseCases/images/StatefullVNF-VNFCfailureNoRed.png Binary files differnew file mode 100644 index 0000000..4fd7e2e --- /dev/null +++ b/UseCases/images/StatefullVNF-VNFCfailureNoRed.png diff --git a/UseCases/images/StatelessVNF-VMfailure.png b/UseCases/images/StatelessVNF-VMfailure.png Binary files differnew file mode 100644 index 0000000..9b94183 --- /dev/null +++ b/UseCases/images/StatelessVNF-VMfailure.png diff --git a/UseCases/images/StatelessVNF-VMfailureNoRed.png b/UseCases/images/StatelessVNF-VMfailureNoRed.png Binary files differnew file mode 100644 index 0000000..2a14b67 --- /dev/null +++ b/UseCases/images/StatelessVNF-VMfailureNoRed.png diff --git a/UseCases/images/StatelessVNF-VNFCfailure.png b/UseCases/images/StatelessVNF-VNFCfailure.png Binary files differnew file mode 100644 index 0000000..f2dcc3b --- /dev/null +++ b/UseCases/images/StatelessVNF-VNFCfailure.png diff --git a/UseCases/images/StatelessVNF-VNFCfailureNoRed-Escalation.png b/UseCases/images/StatelessVNF-VNFCfailureNoRed-Escalation.png Binary files differnew file mode 100644 index 0000000..6719177 --- /dev/null +++ b/UseCases/images/StatelessVNF-VNFCfailureNoRed-Escalation.png diff --git a/UseCases/images/StatelessVNF-VNFCfailureNoRed.png b/UseCases/images/StatelessVNF-VNFCfailureNoRed.png Binary files differnew file mode 100644 index 0000000..a0970fc --- /dev/null +++ b/UseCases/images/StatelessVNF-VNFCfailureNoRed.png |