+# Drydock BaremetalNode resources for a specific rack are stored in this file.
+#
+# NOTE: For new sites, you should complete the networks/physical/networks.yaml
+# file before working on this file.
+#
+# In this file, you should make the number of `drydock/BaremetalNode/v1`
+# resources equal the number of bare metal nodes you have, either by deleting
+# excess BaremetalNode definitions (if there are too many), or by copying and
+# pasting the last BaremetalNode in the file until you have the correct number
+# of baremetal nodes (if there are too few).
+#
+# Then in each file, address all additional NEWSITE-CHANGEME markers to update
+# the data in these files with the right values for your new site.
+#
+# *NOTE: The Genesis node is counted as one of the control plane nodes. Note
+# that the Genesis node does not appear on this bare metal list, because the
+# procedure to reprovision the Genesis host with MaaS has not yet been
+# implemented. Therefore there will be only two bare metal nodes in this file
+# with the 'masters' tag, as the genesis roles are assigned in a different
+# place (type/cntt/profiles/genesis.yaml).
+#
+schema: 'drydock/BaremetalNode/v1'
+metadata:
+ schema: 'metadata/Document/v1'
+ # NEWSITE-CHANGEME: Replace with the hostname of the first node in the rack,
+ # after (excluding) genesis.
+ name: pod15-node2
+ layeringDefinition:
+ abstract: false
+ layer: site
+ storagePolicy: cleartext
+data:
+ # NEWSITE-CHANGEME: The IPv4 address assigned to each logical network on this
+ # node. In the reference Airship deployment, this is all logical Networks defined
+ # in networks/physical/networks.yaml. IP addresses are manually assigned, by-hand.
+ # (what could possibly go wrong!) The instructions differ for each logical
+ # network, which are laid out below.
+ addressing:
+ # The iDrac/iLo IP of the node. It's important that this match up with the
+ # node's hostname above, so that the rack number and node position encoded
+ # in the hostname are accurate and matching the node that IPMI operations
+ # will be performed against (for poweron, poweroff, PXE boot to wipe disk or
+ # reconfigure identity, etc - very important to get right for these reasons).
+ # These addresses should already be assigned to nodes racked and stacked in
+ # the environment; these are not addresses which MaaS assigns.
+ - network: oob
+ address: 10.10.150.12
+ # The IP of the node on the DMZ network. Refer to the static IP range
+ # defined for the Admin network in networks/physical/networks.yaml.
+ - network: dmz
+ address: 10.10.150.22
+ # The IP of the node on the Admin network. Refer to the static IP range
+ # defined for the Admin network in networks/physical/networks.yaml.
+ # This network is used for PXE bootstrapping of the bare-metal servers.
+ - network: admin
+ address: 10.10.151.22
+ # The IP of the node on the Private network. Refer to the static IP range
+ # defined for the Private network in networks/physical/networks.yaml.
+ - network: private
+ address: 10.10.152.22
+ # The IP of the node on the Storage network. Refer to the static IP range
+ # defined for the Storage network in networks/physical/networks.yaml.
+ - network: storage
+ address: 10.10.153.22
+ # The IP of the node on the Management network. Refer to the static IP range
+ # defined for the Management network in networks/physical/networks.yaml.
+ - network: management
+ address: 10.10.154.22
+ # NEWSITE-CHANGEME: Set the host profile for the node.
+ # Note that there are different host profiles depending if this is a control
+ # plane vs data plane node, and different profiles that map to different types
+ # hardware. Select the host profile that matches up to your type of
+ # hardware and function. E.g., the r720 here refers to Dell R720 hardware, the
+ # 'cp' refers to a control plane profile. Refer to profiles/host/ for the list
+ # of available host profiles specific to this site (otherwise, you may find
+ # a general set of host profiles at the "type" or "global" layers/folders.
+ # If you have hardware that is not on this list of profiles, you may need to
+ # create a new host profile for that hardware.
+ host_profile: cp-intel-pod15
+ metadata:
+ tags:
+ # NEWSITE-CHANGEME: See previous comment. Apply 'masters' tag for control
+ # plane node, and 'workers' tag for data plane hosts.
+ - 'masters'
+ # NEWSITE-CHANGEME: Refer to site engineering package or other supporting
+ # documentation for the specific rack name. This should be a rack name that
+ # is meaningful to data center personnel (i.e. a rack they could locate if
+ # you gave them this rack designation).
+ rack: pod15-rack
+...
+---
+schema: 'drydock/BaremetalNode/v1'
+metadata:
+ schema: 'metadata/Document/v1'
+ # NEWSITE-CHANGEME: The next node's hostname
+ name: pod15-node3
+ layeringDefinition:
+ abstract: false
+ layer: site
+ storagePolicy: cleartext
+data:
+ # NEWSITE-CHANGEME: The next node's IPv4 addressing
+ addressing:
+ - network: oob
+ address: 10.10.150.13
+ - network: dmz
+ address: 10.10.150.23
+ - network: admin
+ address: 10.10.151.23
+ - network: private
+ address: 10.10.152.23
+ - network: storage
+ address: 10.10.153.23
+ - network: management
+ address: 10.10.154.23
+ # NEWSITE-CHANGEME: The next node's host profile
+ host_profile: cp-intel-pod15
+ metadata:
+ # NEWSITE-CHANGEME: The next node's rack designation
+ rack: pod15-rack
+ # NEWSITE-CHANGEME: The next node's role desigatnion
+ tags:
+ - 'masters'
+...
+---
+schema: 'drydock/BaremetalNode/v1'
+metadata:
+ schema: 'metadata/Document/v1'
+ # NEWSITE-CHANGEME: The next node's hostname
+ name: pod15-node4
+ layeringDefinition:
+ abstract: false
+ layer: site
+ storagePolicy: cleartext
+data:
+ # NEWSITE-CHANGEME: The next node's IPv4 addressing
+ addressing:
+ - network: oob
+ address: 10.10.150.14
+ - network: dmz
+ address: 10.10.150.24
+ - network: admin
+ address: 10.10.151.24
+ - network: private
+ address: 10.10.152.24
+ - network: storage
+ address: 10.10.153.24
+ - network: management
+ address: 10.10.154.24
+ # NEWSITE-CHANGEME: The next node's host profile
+ host_profile: dp-intel-pod15
+ metadata:
+ # NEWSITE-CHANGEME: The next node's rack designation
+ rack: pod15-rack
+ # NEWSITE-CHANGEME: The next node's role desigatnion
+ tags:
+ - 'workers'
+...
+---
+schema: 'drydock/BaremetalNode/v1'
+metadata:
+ schema: 'metadata/Document/v1'
+ # NEWSITE-CHANGEME: The next node's hostname
+ name: pod15-node5
+ layeringDefinition:
+ abstract: false
+ layer: site
+ storagePolicy: cleartext
+data:
+ # NEWSITE-CHANGEME: The next node's IPv4 addressing
+ addressing:
+ - network: oob
+ address: 10.10.150.15
+ - network: dmz
+ address: 10.10.150.25
+ - network: admin
+ address: 10.10.151.25
+ - network: private
+ address: 10.10.152.25
+ - network: storage
+ address: 10.10.153.25
+ - network: management
+ address: 10.10.154.25
+ # NEWSITE-CHANGEME: The next node's host profile
+ host_profile: dp-intel-pod15
+ metadata:
+ # NEWSITE-CHANGEME: The next node's rack designation
+ rack: pod15-rack
+ # NEWSITE-CHANGEME: The next node's role desigatnion
+ tags:
+ - 'workers'
+...