From af7f0bea3a0d24bdf084622acc9932ccd261e42e Mon Sep 17 00:00:00 2001 From: rexlee8776 Date: Thu, 12 Apr 2018 06:53:17 +0000 Subject: Bugfix: interface down HA tc050 attack and monitor logistic wrong 1. simplify the attack to be one interface 2. move monitor step before attack 3. update rst doc to match JIRA: YARDSTICK-1120 Change-Id: Icfa21d58e7ccdbeaca8a9a1a3098cceb21c981c3 Signed-off-by: rexlee8776 --- .../user/userguide/opnfv_yardstick_tc050.rst | 52 +++++++++++----------- 1 file changed, 25 insertions(+), 27 deletions(-) (limited to 'docs/testing/user/userguide') diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc050.rst b/docs/testing/user/userguide/opnfv_yardstick_tc050.rst index 8890c9d53..82a491b72 100644 --- a/docs/testing/user/userguide/opnfv_yardstick_tc050.rst +++ b/docs/testing/user/userguide/opnfv_yardstick_tc050.rst @@ -34,23 +34,20 @@ Yardstick Test Case Description TC050 | | 2) host: which is the name of a control node being attacked. | | | 3) interface: the network interface to be turned off. | | | | -| | There are four instance of the "close-interface" monitor: | -| | attacker1(for public netork): | -| | -fault_type: "close-interface" | -| | -host: node1 | -| | -interface: "br-ex" | -| | attacker2(for management netork): | -| | -fault_type: "close-interface" | -| | -host: node1 | -| | -interface: "br-mgmt" | -| | attacker3(for storage netork): | -| | -fault_type: "close-interface" | -| | -host: node1 | -| | -interface: "br-storage" | -| | attacker4(for private netork): | -| | -fault_type: "close-interface" | -| | -host: node1 | -| | -interface: "br-mesh" | +| | The interface to be closed by the attacker can be set by the | +| | variable of "{{ interface_name }}" | +| | | +| | attackers: | +| | - | +| | fault_type: "general-attacker" | +| | host: {{ attack_host }} | +| | key: "close-br-public" | +| | attack_key: "close-interface" | +| | action_parameter: | +| | interface: {{ interface_name }} | +| | rollback_parameter: | +| | interface: {{ interface_name }} | +| | | +--------------+--------------------------------------------------------------+ |monitors | In this test case, the monitor named "openstack-cmd" is | | | needed. The monitor needs needs two parameters: | @@ -61,17 +58,17 @@ Yardstick Test Case Description TC050 | | | | | There are four instance of the "openstack-cmd" monitor: | | | monitor1: | -| | -monitor_type: "openstack-cmd" | -| | -command_name: "nova image-list" | +| | - monitor_type: "openstack-cmd" | +| | - command_name: "nova image-list" | | | monitor2: | -| | -monitor_type: "openstack-cmd" | -| | -command_name: "neutron router-list" | +| | - monitor_type: "openstack-cmd" | +| | - command_name: "neutron router-list" | | | monitor3: | -| | -monitor_type: "openstack-cmd" | -| | -command_name: "heat stack-list" | +| | - monitor_type: "openstack-cmd" | +| | - command_name: "heat stack-list" | | | monitor4: | -| | -monitor_type: "openstack-cmd" | -| | -command_name: "cinder list" | +| | - monitor_type: "openstack-cmd" | +| | - command_name: "cinder list" | +--------------+--------------------------------------------------------------+ |metrics | In this test case, there is one metric: | | | 1)service_outage_time: which indicates the maximum outage | @@ -109,9 +106,9 @@ Yardstick Test Case Description TC050 +--------------+--------------------------------------------------------------+ |step 2 | do attacker: connect the host through SSH, and then execute | | | the turnoff network interface script with param value | -| | specified by "interface". | +| | specified by "{{ interface_name }}". | | | | -| | Result: Network interfaces will be turned down. | +| | Result: The specified network interface will be down. | | | | +--------------+--------------------------------------------------------------+ |step 3 | stop monitors after a period of time specified by | @@ -133,3 +130,4 @@ Yardstick Test Case Description TC050 | | execution problem. | | | | +--------------+--------------------------------------------------------------+ + -- cgit 1.2.3-korg