This addresses the IndexError in Standalone SRIOV/OVSDPDK context.
The correct sys_cpu number should be sys_cpu-1
Error:
threads = "%s-%s" % (soc_cpu[socket][sys_cpu], soc_cpu[socket][-1])
IndexError: list index out of range
Tested platform: (Hyper-Threading disabled)
NUMA node0 CPU(s): 0-21
NUMA node1 CPU(s): 22-43
With socket equal to 0, sys_cpu value was 22 which resulted to IndexError.
Change-Id: I36b045cacce4caff4b5ddafaa9b6737f1c6df0a1
Signed-off-by: Dino Simeon Madarang <dinox.madarang@intel.com>
Reviewed-by: Alain Jebara <alain.jebara@intel.com>
Reviewed-by: Deepak S <deepak.s@linux.intel.com>
Reviewed-by: Ross Brattain <ross.b.brattain@intel.com>
Reviewed-by: Edward MacGillivray <edward.s.macgillivray@intel.com>
|
|
|
|
GenericTrafficGen class is now an abstract class. Only optional methods
are implemented.
- 'run_traffic' and 'terminate' are mandatory.
- 'listen_traffic', 'verify_traffic' and 'wait_for_instance' are
optional. By default these methods doesn't execute any action.
JIRA: YARDSTICK-853
Change-Id: I2befdaa337af79cc2364bdd7c66183c31c5ab69a
Signed-off-by: Rodolfo Alonso Hernandez <rodolfo.alonso.hernandez@intel.com>
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Fixed the controller IP parsing in "nsb_setup.sh" script. The new
regex expression now accepts "OS_AUTH_URL" as:
* http://10.237.223.168/identity
* http://10.237.223.168:5000/identity
* http://hostname/identity
* http://hostname:5000/identity
JIRA: YARDSTICK-829
Change-Id: Ifaeab991bcbb6aa7b22c3533ab7554527184878b
Signed-off-by: Rodolfo Alonso Hernandez <rodolfo.alonso.hernandez@intel.com>
|
|
JIRA: YARDSTICK-848
The NSB PROX MPLS test uses Binsearch traffic
profile and the mpls traffic profile is a duplicate.
Change-Id: Ie2124cebf306fd6917b70ecd7c23ae12ef4850dc
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
when we create TRex config we sort based on PCI bus address
and create a logical port ordering.
We need to save this port ordering and re-use it everywhere.
redirect vnfd_helper.port_num() to resource_helper.port_num() to
use the logical mapping
Change-Id: Ibff628556d5e11e686e15716a66a3210758c4ff0
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
YARDSTICK-839
In a scale-up test the VNF number can start from
0 to MAX (num_vnf-1)
The NSB PROX BM test nodes are currently marked as:
tg__0: trafficgen_1.yardstick
vnf__0: vnf.yardstick
They need to be changed to the below:
tg__0: tg_0.yardstick
vnf__0: vnf_0.yardstick
Changes done are:
- All BM Prox test cases have tg_0 and vnf_0 as default
test nodes
- The prox-baremetal-1/2/4.yaml sample pod file
- Cleaned Up some unused Prox test/config files
Change-Id: I819011bcb35eda62b17dd3e1035918918c582b13
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
network_services.vnf_generic.vnf.prox_helpers.ProxSocketHelper.rx_stats"
|
|
|
|
|
|
|
|
|
|
|
|
Use Apache 2.0
Change-Id: I199d09f04a5c84a25bd91dceba5e4ed1f93075f6
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Added a new tox environment to check the project requirements against
the OpenStack requirements. The openstack/requirements branch used will
depends on Yardstick release development.
At this point, Yardstick F release must be compliant with OpenStack Pike
release.
Change-Id: I77a4cfa4f99674176c3f5711dc1b6787bb400ecf
Signed-off-by: Rodolfo Alonso Hernandez <rodolfo.alonso.hernandez@intel.com>
|
|
When creating a Neutron security group for a heat template. Add
IPv6 security group rules to access the resouces.
Change-Id: I0b541dfe400121e35908a70778665ee1576f0622
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
|
|
* Remove the method which is unused and is marked as deprecated.
Change-Id: Ie64084fcd26985283c664445b173a757d3d908ab
JIRA: YARDSTICK-838
Signed-off-by: Emma Foley <emma.l.foley@intel.com>
|
|
intel_pmu needs to download a config file based on the
CPU model. When generating VNF images we don't have
access to the actual vCPU that will be used, so we
can't predownload. This code was meant to be a fix
for that by downloading all the configs and then
selecting one that matched the vCPU.
However we have license issues with intel_pmu enven GPLv2 code,
so remove it for now.
Change-Id: I5257ff7c4ddc1d40537dadb29efa40d1d68cb852
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
Changed Copyright notice on tuples.lua from "Intel Copyright" to Apache 2.0
Change-Id: I85e6f9eb86c116d552f86cddf05b3b368b32f776
Signed-off-by: Daniel Martin Buckley <daniel.m.buckley@intel.com>
|
|
Changed how "test_cli_scenario" tests check the presence
of a string.
Fixed "test_scenario_show_Lmbench": logic in [1] was incorrectly
assigning an string value instead of the result of the "in"
clause.
[1] https://github.com/opnfv/yardstick/blob/stable/euphrates/tests/functional/test_cli_scenario.py#L35-L36
Change-Id: I71fceabad972e4c0d9e78cbfeb85dcd6a5ae4bda
Signed-off-by: Rodolfo Alonso Hernandez <rodolfo.alonso.hernandez@intel.com>
|
|
Created two new class functions for Scenario class:
* "get_description" will return the first line of the docstring,
if exists.
* "get_scenario_type" will return the value of "__scenario_type__"
variable.
Change-Id: I8e3b47e33e0bae101b874c3975bb9c383397d188
Signed-off-by: Rodolfo Alonso Hernandez <rodolfo.alonso.hernandez@intel.com>
|
|
JIRA: YARDSTICK-802
Addition of PROX LW_AFTR basked on PROX/DATS v037 test_104_lw_aftr.py
- This support BM and Openstack Heat
- This supports 4 Ports ONLY
- Grafana Dashboards included
- Code Coverage / Unit testing
Change-Id: If2170ab458bf687256d5f1a1e840a3b9d2788ef7
Signed-off-by: Daniel MArtin Buckley <daniel.m.buckley@intel.com>
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
Change-Id: Id8aa734fee431d90cbdc1e0eb2173784ada822fe
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
The links to the docs in README were pointing to Colorodo documentation.
For master, this should not be pinned to a particular release, but
should show the most recent docs at all times.
Change-Id: I3186ea0dbc5105812407a0f87e02d99899a951a0
Signed-off-by: Emma Foley <emma.l.foley@intel.com>
|
|
Users would like to ensure placement of VMs on specific compute nodes so
that the measurements are meaningful. Examples: Measure network
performance in different scenarios (VMs in same host, in different
hosts, across fabric, across tenants)
Example:
context:
name: yardstick
placement_groups:
pgrp1:
policy: "availability"
servers:
tg_0:
floating_ip: true
placement: "pgrp1"
availability_zone: "zone2"
vnf_0:
floating_ip: true
placement: "pgrp1"
availability_zone: "zone1"
Change-Id: I28a757c25ae3f5b3571ab3edd82d51ceba32c302
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
We don't really know what core we are going to use for the
VNF before we generate the MultiPortConfig, so these
methods are incorrect.
We may need some more advanced method to validate
the vCPU topology, but that will probably happen
in the MultiPortConfig
Change-Id: Ifee7ae4589ce0fce67771fb8d8b8dce0a0f06409
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
|
|
This brings it to parity with its non-Ixia counterpart (ipv4_throughput.yaml).
Change-Id: I4c91d1ae507c7b5e0a23dcf49606b16891b400bd
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
JIRA: YARDSTICK-831
Change-Id: I587c486572f439952b8a31da664d1e2c1fb8dc27
Signed-off-by: rexlee8776 <limingjiang@huawei.com>
|
|
We used to try to probe all the cores that the VNF was using
and only dump CPU stats for those cores.
We can't really detect those core accurately and we would rather
dump all the core information and let influxdb and grafana filter
the information.
We do end up with excessive KPI output, especially on systems with 88
cores, but this is manageable.
The core logic was partially removed, this finishes the removal.
Change-Id: I5cbb694fd982519e2df54db49a21ed5948e13537
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
|
|
This patch is used to remove the livemigration testcase result loaded
to json as there is no dashboard implemented for the testcase
Change-Id: I7a9589a0bbc5f2a28587c2878da042fc50af18e0
Signed-off-by: Navya Bathula <navyax.bathula@intel.com>
|
|
Change-Id: I0380deec3e41a6dc02571ed9c4fa16e304f7f85e
Signed-off-by: JingLu5 <lvjing5@huawei.com>
|
|
JIRA: YARDSTICK-73
add a new chapter about how to work with test case, now just add three sub chapter,
sample test case, release test case, test case description file, will update more for
how to write a new test case.
Change-Id: I44906917e76ad6d4890f345c963b9e4440f6be39
Signed-off-by: kubi <jean.gaoliang@huawei.com>
|
|
- concurrency
- connections/second
- throughput
Change-Id: Idb977462952fba2e6a9684e916dfeca810f1ee94
Signed-off-by: Jennifer Li <jennifer.li@intel.com>
|
|
rename xe0, xe1 to uplink_0, downlink_0
enumerate tgs/vnfs starting from 0.
add disable_dhcp
Change-Id: Ia4f08b3ad5ab298192c249d04b10a6efbe4f210e
Signed-off-by: Ross Brattain <ross.b.brattain@intel.com>
|
|
As per defect:
- the "context:" stanza of every tc_prox_baremetal*.yaml"
file has an incorrect pathname for the config file
- tc_prox_baremetal_binsearch.yaml and
tc_prox_baremetal_ramp.yaml refer to
"prox-baremetal.yml", which idoes not exist
- incorrect prox bin path
Resolution:
- Unify the pod file name and path for all BM tests
- Prox bin path changed to "/opt/nsb_bin/prox"
Change-Id: I16b25189104ad5585ddc1c2c0dd71b3c4c2aecd3
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
|
|
|
|
Change-Id: I2f98b75e9bbcd3d0cd4666c097a3280dd89eb02a
Signed-off-by: Trevor Bramwell <tbramwell@linuxfoundation.org>
|
|
Update:
Added Prox NSB test case documentation
Change-Id: Ia2f47d823581fc7f193d3123f080dd87f29d4b99
Signed-off-by: Maciej Skrocki <maciej.skrocki@intel.com>
Signed-off-by: Abhijit Sinha <abhijit.sinha@intel.com>
|
|
Change-Id: I09bc55e296d2c641f10819972ec0d48a289432b8
Signed-off-by: JingLu5 <lvjing5@huawei.com>
|