summaryrefslogtreecommitdiffstats
path: root/docs/testing/user/userguide/opnfv_yardstick_tc093.rst
diff options
context:
space:
mode:
authorRex Lee <limingjiang@huawei.com>2018-11-05 09:16:57 +0000
committerGerrit Code Review <gerrit@opnfv.org>2018-11-05 09:16:57 +0000
commit3418d769a4bef9ea351e765fa00ad23986738e76 (patch)
treea47a5fa0dfabe30c4ee698072b40fc3f976700d3 /docs/testing/user/userguide/opnfv_yardstick_tc093.rst
parentabdfd5465473b10670a843dfabfc9f10ad2f6a96 (diff)
parent28e64c520fc2a52c1d3eb736f88ad4608b87c142 (diff)
Merge "[docs] Fix docs {un,}indent warnings in Testcase definitions"
Diffstat (limited to 'docs/testing/user/userguide/opnfv_yardstick_tc093.rst')
-rw-r--r--docs/testing/user/userguide/opnfv_yardstick_tc093.rst43
1 files changed, 24 insertions, 19 deletions
diff --git a/docs/testing/user/userguide/opnfv_yardstick_tc093.rst b/docs/testing/user/userguide/opnfv_yardstick_tc093.rst
index 31fa5d3d3..4e22e8bf3 100644
--- a/docs/testing/user/userguide/opnfv_yardstick_tc093.rst
+++ b/docs/testing/user/userguide/opnfv_yardstick_tc093.rst
@@ -43,14 +43,15 @@ Yardstick Test Case Description TC093
+--------------+--------------------------------------------------------------+
|attackers | In this test case, two attackers called “kill-process” are |
| | needed. These attackers include three parameters: |
-| | 1. fault_type: which is used for finding the attacker's |
-| | scripts. It should be set to 'kill-process' in this test |
| | |
-| | 2. process_name: should be set to the name of the Vswitch |
-| | process |
+| | 1. fault_type: which is used for finding the attacker's |
+| | scripts. It should be set to 'kill-process' in this test |
| | |
-| | 3. host: which is the name of the compute node where the |
-| | Vswitch process is running |
+| | 2. process_name: should be set to the name of the Vswitch |
+| | process |
+| | |
+| | 3. host: which is the name of the compute node where the |
+| | Vswitch process is running |
| | |
| | e.g. -fault_type: "kill-process" |
| | -process_name: "openvswitch" |
@@ -60,16 +61,17 @@ Yardstick Test Case Description TC093
|monitors | This test case utilizes two monitors of type "ip-status" |
| | and one monitor of type "process" to track the following |
| | conditions: |
-| | 1. "ping_same_network_l2": monitor ICMP traffic between |
-| | VMs in the same Neutron network |
| | |
-| | 2. "ping_external_snat": monitor ICMP traffic from VMs to |
-| | an external host on the Internet to verify SNAT |
-| | functionality. |
+| | 1. "ping_same_network_l2": monitor ICMP traffic between |
+| | VMs in the same Neutron network |
+| | |
+| | 2. "ping_external_snat": monitor ICMP traffic from VMs to |
+| | an external host on the Internet to verify SNAT |
+| | functionality. |
| | |
-| | 3. "Vswitch process monitor": a monitor checking the |
-| | state of the specified Vswitch process. It measures |
-| | the recovery time of the given process. |
+| | 3. "Vswitch process monitor": a monitor checking the |
+| | state of the specified Vswitch process. It measures |
+| | the recovery time of the given process. |
| | |
| | Monitors of type "ip-status" use the "ping" utility to |
| | verify reachability of a given target IP. |
@@ -99,6 +101,7 @@ Yardstick Test Case Description TC093
+--------------+--------------------------------------------------------------+
|configuration | This test case needs two configuration files: |
| | 1. test case file: opnfv_yardstick_tc093.yaml |
+| | |
| | - Attackers: see above “attackers” description |
| | - monitor_time: which is the time (seconds) from |
| | starting to stoping the monitors |
@@ -173,12 +176,14 @@ Yardstick Test Case Description TC093
|test verdict | This test fails if the SLAs are not met or if there is a |
| | test case execution problem. The SLAs are define as follows |
| | for this test: |
-| | * SDN Vswitch recovery |
-| | * process_recover_time <= 30 sec |
+| | * SDN Vswitch recovery |
+| | |
+| | * process_recover_time <= 30 sec |
+| | |
+| | * no impact on data plane connectivity during SDN |
+| | Vswitch failure and recovery. |
| | |
-| | * no impact on data plane connectivity during SDN |
-| | Vswitch failure and recovery. |
-| | * packet_drop == 0 |
+| | * packet_drop == 0 |
| | |
+--------------+--------------------------------------------------------------+