.. This work is licensed under a Creative Commons Attribution 4.0 International License. .. http://creativecommons.org/licenses/by/4.0 .. (c) OPNFV, Intel Corporation, AT&T and others. .. _vsperf-design: ====================== VSPERF Design Document ====================== Intended Audience ================= This document is intended to aid those who want to modify the vsperf code. Or to extend it - for example to add support for new traffic generators, deployment scenarios and so on. Usage ===== Example Connectivity to DUT --------------------------- Establish connectivity to the VSPERF DUT Linux host. If this is in an OPNFV lab following the steps provided by `Pharos `_ to `access the POD `_ The followign steps establish the VSPERF environment. Example Command Lines --------------------- List all the cli options: .. code-block:: console $ ./vsperf -h Run all tests that have ``tput`` in their name - ``phy2phy_tput``, ``pvp_tput`` etc.: .. code-block:: console $ ./vsperf --tests 'tput' As above but override default configuration with settings in '10_custom.conf'. This is useful as modifying configuration directly in the configuration files in ``conf/NN_*.py`` shows up as changes under git source control: .. code-block:: console $ ./vsperf --conf-file=/10_custom.conf --tests 'tput' Override specific test parameters. Useful for shortening the duration of tests for development purposes: .. code-block:: console $ ./vsperf --test-params 'TRAFFICGEN_DURATION=10;TRAFFICGEN_RFC2544_TESTS=1;' \ 'TRAFFICGEN_PKT_SIZES=(64,)' pvp_tput Typical Test Sequence ===================== This is a typical flow of control for a test. .. image:: vsperf.png .. _design-configuration: Configuration ============= The conf package contains the configuration files (``*.conf``) for all system components, it also provides a ``settings`` object that exposes all of these settings. Settings are not passed from component to component. Rather they are available globally to all components once they import the conf package. .. code-block:: python from conf import settings ... log_file = settings.getValue('LOG_FILE_DEFAULT') Settings files (``*.conf``) are valid python code so can be set to complex types such as lists and dictionaries as well as scalar types: .. code-block:: python first_packet_size = settings.getValue('PACKET_SIZE_LIST')[0] Configuration Procedure and Precedence -------------------------------------- Configuration files follow a strict naming convention that allows them to be processed in a specific order. All the .conf files are named ``NN_name.conf``, where NN is a decimal number. The files are processed in order from 00_name.conf to 99_name.conf so that if the name setting is given in both a lower and higher numbered conf file then the higher numbered file is the effective setting as it is processed after the setting in the lower numbered file. The values in the file specified by ``--conf-file`` takes precedence over all the other configuration files and does not have to follow the naming convention. .. _paths-documentation: Configuration of PATHS dictionary --------------------------------- VSPERF uses external tools like Open vSwitch and Qemu for execution of testcases. These tools may be downloaded and built automatically (see :ref:`vsperf-installation-script`) or installed manually by user from binary packages. It is also possible to use a combination of both approaches, but it is essential to correctly set paths to all required tools. These paths are stored within a PATHS dictionary, which is evaluated before execution of each testcase, in order to setup testcase specific environment. Values selected for testcase execution are internally stored inside TOOLS dictionary, which is used by VSPERF to execute external tools, load kernel modules, etc. The default configuration of PATHS dictionary is spread among three different configuration files to follow logical grouping of configuration options. Basic description of PATHS dictionary is placed inside ``conf/00_common.conf``. The configuration specific to DPDK and vswitches is located at ``conf/02_vswitch.conf``. The last part related to the Qemu is defined inside ``conf/04_vnf.conf``. Default configuration values can be used in case, that all required tools were downloaded and built automatically by vsperf itself. In case, that some of tools were installed manually from binary packages, then it will be necessary to modify the content of PATHS dictionary accordingly. Dictionary has a specific section of configuration options for every tool type, it means: * ``PATHS['vswitch']`` - contains a separete dictionary for each of vswitches supported by VSPEF Example: .. code-block:: python PATHS['vswitch'] = { 'OvsDpdkVhost': { ... }, 'OvsVanilla' : { ... }, ... } * ``PATHS['dpdk']`` - contains paths to the dpdk sources, kernel modules and tools (e.g. testpmd) Example: .. code-block:: python PATHS['dpdk'] = { 'type' : 'src', 'src': { 'path': os.path.join(ROOT_DIR, 'src/dpdk/dpdk/'), 'modules' : ['uio', os.path.join(RTE_TARGET, 'kmod/igb_uio.ko')], 'bind-tool': 'tools/dpdk*bind.py', 'testpmd': os.path.join(RTE_TARGET, 'app', 'testpmd'), }, ... } * ``PATHS['qemu']`` - contains paths to the qemu sources and executable file Example: .. code-block:: python PATHS['qemu'] = { 'type' : 'bin', 'bin': { 'qemu-system': 'qemu-system-x86_64' }, ... } Every section specific to the particular vswitch, dpdk or qemu may contain following types of configuration options: * option ``type`` - is a string, which defines the type of configured paths ('src' or 'bin') to be selected for a given section: * value ``src`` means, that VSPERF will use vswitch, DPDK or QEMU built from sources e.g. by execution of ``systems/build_base_machine.sh`` script during VSPERF installation * value ``bin`` means, that VSPERF will use vswitch, DPDK or QEMU binaries installed directly in the operating system, e.g. via OS specific packaging system * option ``path`` - is a string with a valid system path; Its content is checked for existence, prefixed with section name and stored into TOOLS for later use e.g. ``TOOLS['dpdk_src']`` or ``TOOLS['vswitch_src']`` * option ``modules`` - is list of strings with names of kernel modules; Every module name from given list is checked for a '.ko' suffix. In case that it matches and if it is not an absolute path to the module, then module name is prefixed with value of ``path`` option defined for the same section Example: .. code-block:: python """ snippet of PATHS definition from the configuration file: """ PATHS['vswitch'] = { 'OvsVanilla' = { 'type' : 'src', 'src': { 'path': '/tmp/vsperf/src_vanilla/ovs/ovs/', 'modules' : ['datapath/linux/openvswitch.ko'], ... }, ... } ... } """ Final content of TOOLS dictionary used during runtime: """ TOOLS['vswitch_modules'] = ['/tmp/vsperf/src_vanilla/ovs/ovs/datapath/linux/openvswitch.ko'] * all other options are strings with names and paths to specific tools; If a given string contains a relative path and option ``path`` is defined for a given section, then string content will be prefixed with content of the ``path``. Otherwise the name of the tool will be searched within standard system directories. In case that filename contains OS specific wildcards, then they will be expanded to the real path. At the end of the processing, every absolute path will be checked for its existence. In case that temporary path (i.e. path with a ``_tmp`` suffix) does not exist, then log will be written and vsperf will continue. If any other path will not exist, then vsperf execution will be terminated with a runtime error. Example: .. code-block:: python """ snippet of PATHS definition from the configuration file: """ PATHS['vswitch'] = { 'OvsDpdkVhost': { 'type' : 'src', 'src': { 'path': '/tmp/vsperf/src_vanilla/ovs/ovs/', 'ovs-vswitchd': 'vswitchd/ovs-vswitchd', 'ovsdb-server': 'ovsdb/ovsdb-server', ... } ... } ... } """ Final content of TOOLS dictionary used during runtime: """ TOOLS['ovs-vswitchd'] = '/tmp/vsperf/src_vanilla/ovs/ovs/vswitchd/ovs-vswitchd' TOOLS['ovsdb-server'] = '/tmp/vsperf/src_vanilla/ovs/ovs/ovsdb/ovsdb-server' Note: In case that ``bin`` type is set for DPDK, then ``TOOLS['dpdk_src']`` will be set to the value of ``PATHS['dpdk']['src']['path']``. The reason is, that VSPERF uses downloaded DPDK sources to copy DPDK and testpmd into the GUEST, where testpmd is built. In case, that DPDK sources are not available, then vsperf will continue with test execution, but testpmd can't be used as a guest loopback. This is useful in case, that other guest loopback applications (e.g. buildin or l2fwd) are used. Note: In case of RHEL 7.3 OS usage, binary package configuration is required for Vanilla OVS tests. With the installation of a supported rpm for OVS there is a section in the ``conf\10_custom.conf`` file that can be used. .. _configuration-of-traffic-dictionary: Configuration of TRAFFIC dictionary ----------------------------------- TRAFFIC dictionary is used for configuration of traffic generator. Default values can be found in configuration file ``conf/03_traffic.conf``. These default values can be modified by (first option has the highest priorty): 1. ``Parameters`` section of testcase defintion 2. command line options specified by ``--test-params`` argument 3. custom configuration file It is to note, that in case of option 1 and 2, it is possible to specify only values, which should be changed. In case of custom configuration file, it is required to specify whole ``TRAFFIC`` dictionary with its all values or explicitly call and update() method of ``TRAFFIC`` dictionary. Detailed description of ``TRAFFIC`` dictionary items follows: .. code-block:: console 'traffic_type' - One of the supported traffic types. E.g. rfc2544_throughput, rfc2544_back2back or rfc2544_continuous Data type: str Default value: "rfc2544_throughput". 'bidir' - Specifies if generated traffic will be full-duplex (True) or half-duplex (False) Data type: str Supported values: "True", "False" Default value: "False". 'frame_rate' - Defines desired percentage of frame rate used during continuous stream tests. Data type: int Default value: 100. 'multistream' - Defines number of flows simulated by traffic generator. Value 0 disables multistream feature Data type: int Supported values: 0-65535 Default value: 0. 'stream_type' - Stream type is an extension of the "multistream" feature. If multistream is disabled, then stream type will be ignored. Stream type defines ISO OSI network layer used for simulation of multiple streams. Data type: str Supported values: "L2" - iteration of destination MAC address "L3" - iteration of destination IP address "L4" - iteration of destination port of selected transport protocol Default value: "L4". 'pre_installed_flows' - Pre-installed flows is an extension of the "multistream" feature. If enabled, it will implicitly insert a flow for each stream. If multistream is disabled, then pre-installed flows will be ignored. Note: It is supported only for p2p deployment scenario. Data type: str Supported values: "Yes" - flows will be inserted into OVS "No" - flows won't be inserted into OVS Default value: "No". 'flow_type' - Defines flows complexity. Data type: str Supported values: "port" - flow is defined by ingress ports "IP" - flow is defined by ingress ports and src and dst IP addresses Default value: "port" 'l2' - A dictionary with l2 network layer details. Supported values are: 'srcmac' - Specifies source MAC address filled by traffic generator. NOTE: It can be modified by vsperf in some scenarios. Data type: str Default value: "00:00:00:00:00:00". 'dstmac' - Specifies destination MAC address filled by traffic generator. NOTE: It can be modified by vsperf in some scenarios. Data type: str Default value: "00:00:00:00:00:00". 'framesize' - Specifies default frame size. This value should not be changed directly. It will be overridden during testcase execution by values specified by list TRAFFICGEN_PKT_SIZES. Data type: int Default value: 64 'l3' - A dictionary with l3 network layer details. Supported values are: 'srcip' - Specifies source MAC address filled by traffic generator. NOTE: It can be modified by vsperf in some scenarios. Data type: str Default value: "1.1.1.1". 'dstip' - Specifies destination MAC address filled by traffic generator. NOTE: It can be modified by vsperf in some scenarios. Data type: str Default value: "90.90.90.90". 'proto' - Specifies deflaut protocol type. Please check particular traffic generator implementation for supported protocol types. Data type: str Default value: "udp". 'l4' - A dictionary with l4 network layer details. Supported values are: 'srcport' - Specifies source port of selected transport protocol. NOTE: It can be modified by vsperf in some scenarios. Data type: int Default value: 3000 'dstport' - Specifies destination port of selected transport protocol. NOTE: It can be modified by vsperf in some scenarios. Data type: int Default value: 3001 'vlan' - A dictionary with vlan encapsulation details. Supported values are: 'enabled' - Specifies if vlan encapsulation should be enabled or disabled. Data type: bool Default value: False 'id' - Specifies vlan id. Data type: int (NOTE: must fit to 12 bits) Default value: 0 'priority' - Specifies a vlan priority (PCP header field). Data type: int (NOTE: must fit to 3 bits) Default value: 0 'cfi' - Specifies if frames can or cannot be dropped during congestion (DEI header field). Data type: int (NOTE: must fit to 1 bit) Default value: 0 .. _configuration-of-guest-options: Configuration of GUEST options ------------------------------ VSPERF is able to setup scenarios involving a number of VMs in series or in parallel. All configuration options related to a particular VM instance are defined as lists and prefixed with ``GUEST_`` label. It is essential, that there is enough items in all ``GUEST_`` options to cover all VM instances involved in the test. In case there is not enough items, then VSPERF will use the first item of particular ``GUEST_`` option to expand the list to required length. Example of option expansion for 4 VMs: .. code-block:: python """ Original values: """ GUEST_SMP = ['2'] GUEST_MEMORY = ['2048', '4096'] """ Values after automatic expansion: """ GUEST_SMP = ['2', '2', '2', '2'] GUEST_MEMORY = ['2048', '4096', '2048', '2048'] First option can contain macros starting with ``#`` to generate VM specific values. These macros can be used only for options of ``list`` or ``str`` types with ``GUEST_`` prefix. Example of macros and their expnasion for 2 VMs: .. code-block:: python """ Original values: """ GUEST_SHARE_DIR = ['/tmp/qemu#VMINDEX_share'] GUEST_BRIDGE_IP = ['#IP(1.1.1.5)/16'] """ Values after automatic expansion: """ GUEST_SHARE_DIR = ['/tmp/qemu0_share', '/tmp/qemu1_share'] GUEST_BRIDGE_IP = ['1.1.1.5/16', '1.1.1.6/16'] Additional examples are available at ``04_vnf.conf``. Note: In case, that macro is detected in the first item of the list, then all other items are ignored and list content is created automatically. Multiple macros can be used inside one configuration option definition, but macros cannot be used inside other macros. The only exception is macro ``#VMINDEX``, which is expanded first and thus it can be used inside other macros. Following macros are supported: * ``#VMINDEX`` - it is replaced by index of VM being executed; This macro is expanded first, so it can be used inside other macros. Example: .. code-block:: python GUEST_SHARE_DIR = ['/tmp/qemu#VMINDEX_share'] * ``#MAC(mac_address[, step])`` - it will iterate given ``mac_address`` with optional ``step``. In case that step is not defined, then it is set to 1. It means, that first VM will use the value of ``mac_address``, second VM value of ``mac_address`` increased by ``step``, etc. Example: .. code-block:: python GUEST_NICS = [[{'mac' : '#MAC(00:00:00:00:00:01,2)'}]] * ``#IP(ip_address[, step])`` - it will iterate given ``ip_address`` with optional ``step``. In case that step is not defined, then it is set to 1. It means, that first VM will use the value of ``ip_address``, second VM value of ``ip_address`` increased by ``step``, etc. Example: .. code-block:: python GUEST_BRIDGE_IP = ['#IP(1.1.1.5)/16'] * ``#EVAL(expression)`` - it will evaluate given ``expression`` as python code; Only simple expressions should be used. Call of the functions is not supported. Example: .. code-block:: python GUEST_CORE_BINDING = [('#EVAL(6+2*#VMINDEX)', '#EVAL(7+2*#VMINDEX)')] Other Configuration ------------------- ``conf.settings`` also loads configuration from the command line and from the environment. PXP Deployment ============== Every testcase uses one of the supported deployment scenarios to setup test environment. The controller responsible for a given scenario configures flows in the vswitch to route traffic among physical interfaces connected to the traffic generator and virtual machines. VSPERF supports several deployments including PXP deployment, which can setup various scenarios with multiple VMs. These scenarios are realized by VswitchControllerPXP class, which can configure and execute given number of VMs in serial or parallel configurations. Every VM can be configured with just one or an even number of interfaces. In case that VM has more than 2 interfaces, then traffic is properly routed among pairs of interfaces. Example of traffic routing for VM with 4 NICs in serial configuration: .. code-block:: console +------------------------------------------+ | VM with 4 NICs | | +---------------+ +---------------+ | | | Application | | Application | | | +---------------+ +---------------+ | | ^ | ^ | | | | v | v | | +---------------+ +---------------+ | | | logical ports | | logical ports | | | | 0 1 | | 2 3 | | +--+---------------+----+---------------+--+ ^ : ^ : | | | | : v : v +-----------+---------------+----+---------------+----------+ | vSwitch | 0 1 | | 2 3 | | | | logical ports | | logical ports | | | previous +---------------+ +---------------+ next | | VM or PHY ^ | ^ | VM or PHY| | port -----+ +------------+ +---> port | +-----------------------------------------------------------+ It is also possible to define different number of interfaces for each VM to better simulate real scenarios. Example of traffic routing for 2 VMs in serial configuration, where 1st VM has 4 NICs and 2nd VM 2 NICs: .. code-block:: console +------------------------------------------+ +---------------------+ | 1st VM with 4 NICs | | 2nd VM with 2 NICs | | +---------------+ +---------------+ | | +---------------+ | | | Application | | Application | | | | Application | | | +---------------+ +---------------+ | | +---------------+ | | ^ | ^ | | | ^ | | | | v | v | | | v | | +---------------+ +---------------+ | | +---------------+ | | | logical ports | | logical ports | | | | logical ports | | | | 0 1 | | 2 3 | | | | 0 1 | | +--+---------------+----+---------------+--+ +--+---------------+--+ ^ : ^ : ^ : | | | | | | : v : v : v +-----------+---------------+----+---------------+-------+---------------+----------+ | vSwitch | 0 1 | | 2 3 | | 4 5 | | | | logical ports | | logical ports | | logical ports | | | previous +---------------+ +---------------+ +---------------+ next | | VM or PHY ^ | ^ | ^ | VM or PHY| | port -----+ +------------+ +---------------+ +----> port | +-----------------------------------------------------------------------------------+ The number of VMs involved in the test and the type of their connection is defined by deployment name as follows: * ``pvvp[number]`` - configures scenario with VMs connected in series with optional ``number`` of VMs. In case that ``number`` is not specified, then 2 VMs will be used. Example of 2 VMs in a serial configuration: .. code-block:: console +----------------------+ +----------------------+ | 1st VM | | 2nd VM | | +---------------+ | | +---------------+ | | | Application | | | | Application | | | +---------------+ | | +---------------+ | | ^ | | | ^ | | | | v | | | v | | +---------------+ | | +---------------+ | | | logical ports | | | | logical ports | | | | 0 1 | | | | 0 1 | | +---+---------------+--+ +---+---------------+--+ ^ : ^ : | | | | : v : v +---+---------------+---------+---------------+--+ | | 0 1 | | 3 4 | | | | logical ports | vSwitch | logical ports | | | +---------------+ +---------------+ | | ^ | ^ | | | | +-----------------+ v | | +----------------------------------------+ | | | physical ports | | | | 0 1 | | +---+----------------------------------------+---+ ^ : | | : v +------------------------------------------------+ | | | traffic generator | | | +------------------------------------------------+ * ``pvpv[number]`` - configures scenario with VMs connected in parallel with optional ``number`` of VMs. In case that ``number`` is not specified, then 2 VMs will be used. Multistream feature is used to route traffic to particular VMs (or NIC pairs of every VM). It means, that VSPERF will enable multistream feaure and sets the number of streams to the number of VMs and their NIC pairs. Traffic will be dispatched based on Stream Type, i.e. by UDP port, IP address or MAC address. Example of 2 VMs in a parallel configuration, where traffic is dispatched based on the UDP port. .. code-block:: console +----------------------+ +----------------------+ | 1st VM | | 2nd VM | | +---------------+ | | +---------------+ | | | Application | | | | Application | | | +---------------+ | | +---------------+ | | ^ | | | ^ | | | | v | | | v | | +---------------+ | | +---------------+ | | | logical ports | | | | logical ports | | | | 0 1 | | | | 0 1 | | +---+---------------+--+ +---+---------------+--+ ^ : ^ : | | | | : v : v +---+---------------+---------+---------------+--+ | | 0 1 | | 3 4 | | | | logical ports | vSwitch | logical ports | | | +---------------+ +---------------+ | | ^ | ^ : | | | ......................: : | | UDP | UDP : | : | | port| port: +--------------------+ : | | 0 | 1 : | : | | | : v v | | +----------------------------------------+ | | | physical ports | | | | 0 1 | | +---+----------------------------------------+---+ ^ : | | : v +------------------------------------------------+ | | | traffic generator | | | +------------------------------------------------+ PXP deployment is backward compatible with PVP deployment, where ``pvp`` is an alias for ``pvvp1`` and it executes just one VM. The number of interfaces used by VMs is defined by configuration option ``GUEST_NICS_NR``. In case that more than one pair of interfaces is defined for VM, then: * for ``pvvp`` (serial) scenario every NIC pair is connected in serial before connection to next VM is created * for ``pvpv`` (parallel) scenario every NIC pair is directly connected to the physical ports and unique traffic stream is assigned to it Examples: * Deployment ``pvvp10`` will start 10 VMs and connects them in series * Deployment ``pvpv4`` will start 4 VMs and connects them in parallel * Deployment ``pvpv1`` and GUEST_NICS_NR = [4] will start 1 VM with 4 interfaces and every NIC pair is directly connected to the physical ports * Deployment ``pvvp`` and GUEST_NICS_NR = [2, 4] will start 2 VMs; 1st VM will have 2 interfaces and 2nd VM 4 interfaces. These interfaces will be connected in serial, i.e. traffic will flow as follows: PHY1 -> VM1_1 -> VM1_2 -> VM2_1 -> VM2_2 -> VM2_3 -> VM2_4 -> PHY2 Note: In case that only 1 or more than 2 NICs are configured for VM, then ``testpmd`` should be used as forwarding application inside the VM. As it is able to forward traffic between multiple VM NIC pairs. Note: In case of ``linux_bridge``, all NICs are connected to the same bridge inside the VM. VM, vSwitch, Traffic Generator Independence =========================================== VSPERF supports different vSwithes, Traffic Generators, VNFs and Forwarding Applications by using standard object-oriented polymorphism: * Support for vSwitches is implemented by a class inheriting from IVSwitch. * Support for Traffic Generators is implemented by a class inheriting from ITrafficGenerator. * Support for VNF is implemented by a class inheriting from IVNF. * Support for Forwarding Applications is implemented by a class inheriting from IPktFwd. By dealing only with the abstract interfaces the core framework can support many implementations of different vSwitches, Traffic Generators, VNFs and Forwarding Applications. IVSwitch -------- .. code-block:: python class IVSwitch: start(self) stop(self) add_switch(switch_name) del_switch(switch_name) add_phy_port(switch_name) add_vport(switch_name) get_ports(switch_name) del_port(switch_name, port_name) add_flow(switch_name, flow) del_flow(switch_name, flow=None) ITrafficGenerator ----------------- .. code-block:: python class ITrafficGenerator: connect() disconnect() send_burst_traffic(traffic, numpkts, time, framerate) send_cont_traffic(traffic, time, framerate) start_cont_traffic(traffic, time, framerate) stop_cont_traffic(self): send_rfc2544_throughput(traffic, tests, duration, lossrate) start_rfc2544_throughput(traffic, tests, duration, lossrate) wait_rfc2544_throughput(self) send_rfc2544_back2back(traffic, tests, duration, lossrate) start_rfc2544_back2back(traffic, , tests, duration, lossrate) wait_rfc2544_back2back() Note ``send_xxx()`` blocks whereas ``start_xxx()`` does not and must be followed by a subsequent call to ``wait_xxx()``. IVnf ---- .. code-block:: python class IVnf: start(memory, cpus, monitor_path, shared_path_host, shared_path_guest, guest_prompt) stop() execute(command) wait(guest_prompt) execute_and_wait (command) IPktFwd -------- .. code-block:: python class IPktFwd: start() stop() Controllers ----------- Controllers are used in conjunction with abstract interfaces as way of decoupling the control of vSwtiches, VNFs, TrafficGenerators and Forwarding Applications from other components. The controlled classes provide basic primitive operations. The Controllers sequence and co-ordinate these primitive operation in to useful actions. For instance the vswitch_controller_p2p can be used to bring any vSwitch (that implements the primitives defined in IVSwitch) into the configuration required by the Phy-to-Phy Deployment Scenario. In order to support a new vSwitch only a new implementation of IVSwitch needs be created for the new vSwitch to be capable of fulfilling all the Deployment Scenarios provided for by existing or future vSwitch Controllers. Similarly if a new Deployment Scenario is required it only needs to be written once as a new vSwitch Controller and it will immediately be capable of controlling all existing and future vSwitches in to that Deployment Scenario. Similarly the Traffic Controllers can be used to co-ordinate basic operations provided by implementers of ITrafficGenerator to provide useful tests. Though traffic generators generally already implement full test cases i.e. they both generate suitable traffic and analyse returned traffic in order to implement a test which has typically been predefined in an RFC document. However the Traffic Controller class allows for the possibility of further enhancement - such as iterating over tests for various packet sizes or creating new tests. Traffic Controller's Role ------------------------- .. image:: traffic_controller.png Loader & Component Factory -------------------------- The working of the Loader package (which is responsible for *finding* arbitrary classes based on configuration data) and the Component Factory which is responsible for *choosing* the correct class for a particular situation - e.g. Deployment Scenario can be seen in this diagram. .. image:: factory_and_loader.png Routing Tables ============== Vsperf uses a standard set of routing tables in order to allow tests to easily mix and match Deployment Scenarios (PVP, P2P topology), Tuple Matching and Frame Modification requirements. .. code-block:: console +--------------+ | | | Table 0 | table#0 - Match table. Flows designed to force 5 & 10 | | tuple matches go here. | | +--------------+ | | v +--------------+ table#1 - Routing table. Flow entries to forward | | packets between ports goes here. | Table 1 | The chosen port is communicated to subsequent tables by | | setting the metadata value to the egress port number. | | Generally this table is set-up by by the +--------------+ vSwitchController. | | v +--------------+ table#2 - Frame modification table. Frame modification | | flow rules are isolated in this table so that they can | Table 2 | be turned on or off without affecting the routing or | | tuple-matching flow rules. This allows the frame | | modification and tuple matching required by the tests | | in the VSWITCH PERFORMANCE FOR TELCO NFV test +--------------+ specification to be independent of the Deployment | Scenario set up by the vSwitchController. | v +--------------+ | | | Table 3 | table#3 - Egress table. Egress packets on the ports | | setup in Table 1. +--------------+