+ Troubleshooting Monitors
+=================================
+
+.. index:: monitor, high availability
+
+When a cluster encounters monitor-related troubles there's a tendency to
+panic, and some times with good reason. You should keep in mind that losing
+a monitor, or a bunch of them, don't necessarily mean that your cluster is
+down, as long as a majority is up, running and with a formed quorum.
+Regardless of how bad the situation is, the first thing you should do is to
+calm down, take a breath and try answering our initial troubleshooting script.
+
+
+Initial Troubleshooting
+========================
+
+
+**Are the monitors running?**
+
+ First of all, we need to make sure the monitors are running. You would be
+ amazed by how often people forget to run the monitors, or restart them after
+ an upgrade. There's no shame in that, but let's try not losing a couple of
+ hours chasing an issue that is not there.
+
+**Are you able to connect to the monitor's servers?**
+
+ Doesn't happen often, but sometimes people do have ``iptables`` rules that
+ block accesses to monitor servers or monitor ports. Usually leftovers from
+ monitor stress-testing that were forgotten at some point. Try ssh'ing into
+ the server and, if that succeeds, try connecting to the monitor's port
+ using you tool of choice (telnet, nc,...).
+
+**Does ceph -s run and obtain a reply from the cluster?**
+
+ If the answer is yes then your cluster is up and running. One thing you
+ can take for granted is that the monitors will only answer to a ``status``
+ request if there is a formed quorum.
+
+ If ``ceph -s`` blocked however, without obtaining a reply from the cluster
+ or showing a lot of ``fault`` messages, then it is likely that your monitors
+ are either down completely or just a portion is up -- a portion that is not
+ enough to form a quorum (keep in mind that a quorum if formed by a majority
+ of monitors).
+
+**What if ceph -s doesn't finish?**
+
+ If you haven't gone through all the steps so far, please go back and do.
+
+ For those running on Emperor 0.72-rc1 and forward, you will be able to
+ contact each monitor individually asking them for their status, regardless
+ of a quorum being formed. This an be achieved using ``ceph ping mon.ID``,
+ ID being the monitor's identifier. You should perform this for each monitor
+ in the cluster. In section `Understanding mon_status`_ we will explain how
+ to interpret the output of this command.
+
+ For the rest of you who don't tread on the bleeding edge, you will need to
+ ssh into the server and use the monitor's admin socket. Please jump to
+ `Using the monitor's admin socket`_.
+
+For other specific issues, keep on reading.
+
+
+Using the monitor's admin socket
+=================================
+
+The admin socket allows you to interact with a given daemon directly using a
+Unix socket file. This file can be found in your monitor's ``run`` directory.
+By default, the admin socket will be kept in ``/var/run/ceph/ceph-mon.ID.asok``
+but this can vary if you defined it otherwise. If you don't find it there,
+please check your ``ceph.conf`` for an alternative path or run::
+
+ ceph-conf --name mon.ID --show-config-value admin_socket
+
+Please bear in mind that the admin socket will only be available while the
+monitor is running. When the monitor is properly shutdown, the admin socket
+will be removed. If however the monitor is not running and the admin socket
+still persists, it is likely that the monitor was improperly shutdown.
+Regardless, if the monitor is not running, you will not be able to use the
+admin socket, with ``ceph`` likely returning ``Error 111: Connection Refused``.
+
+Accessing the admin socket is as simple as telling the ``ceph`` tool to use
+the ``asok`` file. In pre-Dumpling Ceph, this can be achieved by::
+
+ ceph --admin-daemon /var/run/ceph/ceph-mon.<id>.asok <command>
+
+while in Dumpling and beyond you can use the alternate (and recommended)
+format::
+
+ ceph daemon mon.<id> <command>
+
+Using ``help`` as the command to the ``ceph`` tool will show you the
+supported commands available through the admin socket. Please take a look
+at ``config get``, ``config show``, ``mon_status`` and ``quorum_status``,
+as those can be enlightening when troubleshooting a monitor.
+
+
+Understanding mon_status
+=========================
+
+``mon_status`` can be obtained through the ``ceph`` tool when you have
+a formed quorum, or via the admin socket if you don't. This command will
+output a multitude of information about the monitor, including the same
+output you would get with ``quorum_status``.
+
+Take the following example of ``mon_status``::
+
+
+ { "name": "c",
+ "rank": 2,
+ "state": "peon",
+ "election_epoch": 38,
+ "quorum": [
+ 1,
+ 2],
+ "outside_quorum": [],
+ "extra_probe_peers": [],
+ "sync_provider": [],
+ "monmap": { "epoch": 3,
+ "fsid": "5c4e9d53-e2e1-478a-8061-f543f8be4cf8",
+ "modified": "2013-10-30 04:12:01.945629",
+ "created": "2013-10-29 14:14:41.914786",
+ "mons": [
+ { "rank": 0,
+ "name": "a",
+ "addr": "127.0.0.1:6789\/0"},
+ { "rank": 1,
+ "name": "b",
+ "addr": "127.0.0.1:6790\/0"},
+ { "rank": 2,
+ "name": "c",
+ "addr": "127.0.0.1:6795\/0"}]}}
+
+A couple of things are obvious: we have three monitors in the monmap (*a*, *b*
+and *c*), the quorum is formed by only two monitors, and *c* is in the quorum
+as a *peon*.
+
+Which monitor is out of the quorum?
+
+ The answer would be **a**.
+
+Why?
+
+ Take a look at the ``quorum`` set. We have two monitors in this set: *1*
+ and *2*. These are not monitor names. These are monitor ranks, as established
+ in the current monmap. We are missing the monitor with rank 0, and according
+ to the monmap that would be ``mon.a``.
+
+By the way, how are ranks established?
+
+ Ranks are (re)calculated whenever you add or remove monitors and follow a
+ simple rule: the **greater** the ``IP:PORT`` combination, the **lower** the
+ rank is. In this case, considering that ``127.0.0.1:6789`` is lower than all
+ the remaining ``IP:PORT`` combinations, ``mon.a`` has rank 0.
+
+Most Common Monitor Issues
+===========================
+
+Have Quorum but at least one Monitor is down
+---------------------------------------------
+
+When this happens, depending on the version of Ceph you are running,
+you should be seeing something similar to::
+
+ $ ceph health detail
+ [snip]
+ mon.a (rank 0) addr 127.0.0.1:6789/0 is down (out of quorum)
+
+How to troubleshoot this?
+
+ First, make sure ``mon.a`` is running.
+
+ Second, make sure you are able to connect to ``mon.a``'s server from the
+ other monitors' servers. Check the ports as well. Check ``iptables`` on
+ all your monitor nodes and make sure you are not dropping/rejecting
+ connections.
+
+ If this initial troubleshooting doesn't solve your problems, then it's
+ time to go deeper.
+
+ First, check the problematic monitor's ``mon_status`` via the admin
+ socket as explained in `Using the monitor's admin socket`_ and
+ `Understanding mon_status`_.
+
+ Considering the monitor is out of the quorum, its state should be one of
+ ``probing``, ``electing`` or ``synchronizing``. If it happens to be either
+ ``leader`` or ``peon``, then the monitor believes to be in quorum, while
+ the remaining cluster is sure it is not; or maybe it got into the quorum
+ while we were troubleshooting the monitor, so check you ``ceph -s`` again
+ just to make sure. Proceed if the monitor is not yet in the quorum.
+
+What if the state is ``probing``?
+
+ This means the monitor is still looking for the other monitors. Every time
+ you start a monitor, the monitor will stay in this state for some time
+ while trying to find the rest of the monitors specified in the ``monmap``.
+ The time a monitor will spend in this state can vary. For instance, when on
+ a single-monitor cluster, the monitor will pass through the probing state
+ almost instantaneously, since there are no other monitors around. On a
+ multi-monitor cluster, the monitors will stay in this state until they
+ find enough monitors to form a quorum -- this means that if you have 2 out
+ of 3 monitors down, the one remaining monitor will stay in this state
+ indefinitively until you bring one of the other monitors up.
+
+ If you have a quorum, however, the monitor should be able to find the
+ remaining monitors pretty fast, as long as they can be reached. If your
+ monitor is stuck probing and you have gone through with all the communication
+ troubleshooting, then there is a fair chance that the monitor is trying
+ to reach the other monitors on a wrong address. ``mon_status`` outputs the
+ ``monmap`` known to the monitor: check if the other monitor's locations
+ match reality. If they don't, jump to
+ `Recovering a Monitor's Broken monmap`_; if they do, then it may be related
+ to severe clock skews amongst the monitor nodes and you should refer to
+ `Clock Skews`_ first, but if that doesn't solve your problem then it is
+ the time to prepare some logs and reach out to the community (please refer
+ to `Preparing your logs`_ on how to best prepare your logs).
+
+
+What if state is ``electing``?
+
+ This means the monitor is in the middle of an election. These should be
+ fast to complete, but at times the monitors can get stuck electing. This
+ is usually a sign of a clock skew among the monitor nodes; jump to
+ `Clock Skews`_ for more infos on that. If all your clocks are properly
+ synchronized, it is best if you prepare some logs and reach out to the
+ community. This is not a state that is likely to persist and aside from
+ (*really*) old bugs there is not an obvious reason besides clock skews on
+ why this would happen.
+
+What if state is ``synchronizing``?
+
+ This means the monitor is synchronizing with the rest of the cluster in
+ order to join the quorum. The synchronization process is as faster as
+ smaller your monitor store is, so if you have a big store it may
+ take a while. Don't worry, it should be finished soon enough.
+
+ However, if you notice that the monitor jumps from ``synchronizing`` to
+ ``electing`` and then back to ``synchronizing``, then you do have a
+ problem: the cluster state is advancing (i.e., generating new maps) way
+ too fast for the synchronization process to keep up. This used to be a
+ thing in early Cuttlefish, but since then the synchronization process was
+ quite refactored and enhanced to avoid just this sort of behavior. If this
+ happens in later versions let us know. And bring some logs
+ (see `Preparing your logs`_).
+
+What if state is ``leader`` or ``peon``?
+
+ This should not happen. There is a chance this might happen however, and
+ it has a lot to do with clock skews -- see `Clock Skews`_. If you are not
+ suffering from clock skews, then please prepare your logs (see
+ `Preparing your logs`_) and reach out to us.
+
+
+Recovering a Monitor's Broken monmap
+-------------------------------------
+
+This is how a ``monmap`` usually looks like, depending on the number of
+monitors::
+
+
+ epoch 3
+ fsid 5c4e9d53-e2e1-478a-8061-f543f8be4cf8
+ last_changed 2013-10-30 04:12:01.945629
+ created 2013-10-29 14:14:41.914786
+ 0: 127.0.0.1:6789/0 mon.a
+ 1: 127.0.0.1:6790/0 mon.b
+ 2: 127.0.0.1:6795/0 mon.c
+
+This may not be what you have however. For instance, in some versions of
+early Cuttlefish there was this one bug that could cause your ``monmap``
+to be nullified. Completely filled with zeros. This means that not even
+``monmaptool`` would be able to read it because it would find it hard to
+make sense of only-zeros. Some other times, you may end up with a monitor
+with a severely outdated monmap, thus being unable to find the remaining
+monitors (e.g., say ``mon.c`` is down; you add a new monitor ``mon.d``,
+then remove ``mon.a``, then add a new monitor ``mon.e`` and remove
+``mon.b``; you will end up with a totally different monmap from the one
+``mon.c`` knows).
+
+In this sort of situations, you have two possible solutions:
+
+Scrap the monitor and create a new one
+
+ You should only take this route if you are positive that you won't
+ lose the information kept by that monitor; that you have other monitors
+ and that they are running just fine so that your new monitor is able
+ to synchronize from the remaining monitors. Keep in mind that destroying
+ a monitor, if there are no other copies of its contents, may lead to
+ loss of data.
+
+Inject a monmap into the monitor
+
+ Usually the safest path. You should grab the monmap from the remaining
+ monitors and inject it into the monitor with the corrupted/lost monmap.
+
+ These are the basic steps:
+
+ 1. Is there a formed quorum? If so, grab the monmap from the quorum::
+
+ $ ceph mon getmap -o /tmp/monmap
+
+ 2. No quorum? Grab the monmap directly from another monitor (this
+ assumes the monitor you are grabbing the monmap from has id ID-FOO
+ and has been stopped)::
+
+ $ ceph-mon -i ID-FOO --extract-monmap /tmp/monmap
+
+ 3. Stop the monitor you are going to inject the monmap into.
+
+ 4. Inject the monmap::
+
+ $ ceph-mon -i ID --inject-monmap /tmp/monmap
+
+ 5. Start the monitor
+
+ Please keep in mind that the ability to inject monmaps is a powerful
+ feature that can cause havoc with your monitors if misused as it will
+ overwrite the latest, existing monmap kept by the monitor.
+
+
+Clock Skews
+------------
+
+Monitors can be severely affected by significant clock skews across the
+monitor nodes. This usually translates into weird behavior with no obvious
+cause. To avoid such issues, you should run a clock synchronization tool
+on your monitor nodes.
+
+
+What's the maximum tolerated clock skew?
+
+ By default the monitors will allow clocks to drift up to ``0.05 seconds``.
+
+
+Can I increase the maximum tolerated clock skew?
+
+ This value is configurable via the ``mon-clock-drift-allowed`` option, and
+ although you *CAN* it doesn't mean you *SHOULD*. The clock skew mechanism
+ is in place because clock skewed monitor may not properly behave. We, as
+ developers and QA afficcionados, are comfortable with the current default
+ value, as it will alert the user before the monitors get out hand. Changing
+ this value without testing it first may cause unforeseen effects on the
+ stability of the monitors and overall cluster healthiness, although there is
+ no risk of dataloss.
+
+
+How do I know there's a clock skew?
+
+ The monitors will warn you in the form of a ``HEALTH_WARN``. ``ceph health
+ detail`` should show something in the form of::
+
+ mon.c addr 10.10.0.1:6789/0 clock skew 0.08235s > max 0.05s (latency 0.0045s)
+
+ That means that ``mon.c`` has been flagged as suffering from a clock skew.
+
+
+What should I do if there's a clock skew?
+
+ Synchronize your clocks. Running an NTP client may help. If you are already
+ using one and you hit this sort of issues, check if you are using some NTP
+ server remote to your network and consider hosting your own NTP server on
+ your network. This last option tends to reduce the amount of issues with
+ monitor clock skews.
+
+
+Client Can't Connect or Mount
+------------------------------
+
+Check your IP tables. Some OS install utilities add a ``REJECT`` rule to
+``iptables``. The rule rejects all clients trying to connect to the host except
+for ``ssh``. If your monitor host's IP tables have such a ``REJECT`` rule in
+place, clients connecting from a separate node will fail to mount with a timeout
+error. You need to address ``iptables`` rules that reject clients trying to
+connect to Ceph daemons. For example, you would need to address rules that look
+like this appropriately::
+
+ REJECT all -- anywhere anywhere reject-with icmp-host-prohibited
+
+You may also need to add rules to IP tables on your Ceph hosts to ensure
+that clients can access the ports associated with your Ceph monitors (i.e., port
+6789 by default) and Ceph OSDs (i.e., 6800 through 7300 by default). For
+example::
+
+ iptables -A INPUT -m multiport -p tcp -s {ip-address}/{netmask} --dports 6789,6800:7300 -j ACCEPT
+
+Monitor Store Failures
+======================
+
+Symptoms of store corruption
+----------------------------
+
+Ceph monitor stores the `cluster map`_ in a key/value store such as LevelDB. If
+a monitor fails due to the key/value store corruption, following error messages
+might be found in the monitor log::
+
+ Corruption: error in middle of record
+
+or::
+
+ Corruption: 1 missing files; e.g.: /var/lib/ceph/mon/mon.0/store.db/1234567.ldb
+
+Recovery using healthy monitor(s)
+---------------------------------
+
+If there is any survivers, we can always `replace`_ the corrupted one with a
+new one. And after booting up, the new joiner will sync up with a healthy
+peer, and once it is fully sync'ed, it will be able to serve the clients.
+
+Recovery using OSDs
+-------------------
+
+But what if all monitors fail at the same time? Since users are encouraged to
+deploy at least three monitors in a Ceph cluster, the chance of simultaneous
+failure is rare. But unplanned power-downs in a data center with improperly
+configured disk/fs settings could fail the underlying filesystem, and hence
+kill all the monitors. In this case, we can recover the monitor store with the
+information stored in OSDs.::
+
+ ms=/tmp/mon-store
+ mkdir $ms
+ # collect the cluster map from OSDs
+ for host in $hosts; do
+ rsync -avz $ms user@host:$ms
+ rm -rf $ms
+ ssh user@host <<EOF
+ for osd in /var/lib/osd/osd-*; do
+ ceph-objectstore-tool --data-path \$osd --op update-mon-db --mon-store-path $ms
+ done
+ EOF
+ rsync -avz user@host:$ms $ms
+ done
+ # rebuild the monitor store from the collected map, if the cluster does not
+ # use cephx authentication, we can skip the following steps to update the
+ # keyring with the caps, and there is no need to pass the "--keyring" option.
+ # i.e. just use "ceph-monstore-tool /tmp/mon-store rebuild" instead
+ ceph-authtool /path/to/admin.keyring -n mon. \
+ --cap mon 'allow *'
+ ceph-authtool /path/to/admin.keyring -n client.admin \
+ --cap mon 'allow *' --cap osd 'allow *' --cap mds 'allow *'
+ ceph-monstore-tool /tmp/mon-store rebuild -- --keyring /path/to/admin.keyring
+ # backup corrupted store.db just in case
+ mv /var/lib/ceph/mon/mon.0/store.db /var/lib/ceph/mon/mon.0/store.db.corrupted
+ mv /tmp/mon-store/store.db /var/lib/ceph/mon/mon.0/store.db
+ chown -R ceph:ceph /var/lib/ceph/mon/mon.0/store.db
+
+The steps above
+
+#. collect the map from all OSD hosts,
+#. then rebuild the store,
+#. fill the entities in keyring file with appropriate caps
+#. replace the corrupted store on ``mon.0`` with the recovered copy.
+
+Known limitations
+~~~~~~~~~~~~~~~~~
+
+Following information are not recoverable using the steps above:
+
+- **some added keyrings**: all the OSD keyrings added using ``ceph auth add`` command
+ are recovered from the OSD's copy. And the ``client.admin`` keyring is imported
+ using ``ceph-monstore-tool``. But the MDS keyrings and other keyrings are missing
+ in the recovered monitor store. You might need to re-add them manually.
+
+- **pg settings**: the ``full ratio`` and ``nearfull ratio`` settings configured using
+ ``ceph pg set_full_ratio`` and ``ceph pg set_nearfull_ratio`` will be lost.
+
+- **MDS Maps**: the MDS maps are lost.
+
+
+Everything Failed! Now What?
+=============================
+
+Reaching out for help
+----------------------
+
+You can find us on IRC at #ceph and #ceph-devel at OFTC (server irc.oftc.net)
+and on ``ceph-devel@vger.kernel.org`` and ``ceph-users@lists.ceph.com``. Make
+sure you have grabbed your logs and have them ready if someone asks: the faster
+the interaction and lower the latency in response, the better chances everyone's
+time is optimized.
+
+
+Preparing your logs
+---------------------
+
+Monitor logs are, by default, kept in ``/var/log/ceph/ceph-mon.FOO.log*``. We
+may want them. However, your logs may not have the necessary information. If
+you don't find your monitor logs at their default location, you can check
+where they should be by running::
+
+ ceph-conf --name mon.FOO --show-config-value log_file
+
+The amount of information in the logs are subject to the debug levels being
+enforced by your configuration files. If you have not enforced a specific
+debug level then Ceph is using the default levels and your logs may not
+contain important information to track down you issue.
+A first step in getting relevant information into your logs will be to raise
+debug levels. In this case we will be interested in the information from the
+monitor.
+Similarly to what happens on other components, different parts of the monitor
+will output their debug information on different subsystems.
+
+You will have to raise the debug levels of those subsystems more closely
+related to your issue. This may not be an easy task for someone unfamiliar
+with troubleshooting Ceph. For most situations, setting the following options
+on your monitors will be enough to pinpoint a potential source of the issue::
+
+ debug mon = 10
+ debug ms = 1
+
+If we find that these debug levels are not enough, there's a chance we may
+ask you to raise them or even define other debug subsystems to obtain infos
+from -- but at least we started off with some useful information, instead
+of a massively empty log without much to go on with.
+
+Do I need to restart a monitor to adjust debug levels?
+------------------------------------------------------
+
+No. You may do it in one of two ways:
+
+You have quorum
+
+ Either inject the debug option into the monitor you want to debug::
+
+ ceph tell mon.FOO injectargs --debug_mon 10/10
+
+ or into all monitors at once::
+
+ ceph tell mon.* injectargs --debug_mon 10/10
+
+No quourm
+
+ Use the monitor's admin socket and directly adjust the configuration
+ options::
+
+ ceph daemon mon.FOO config set debug_mon 10/10
+
+
+Going back to default values is as easy as rerunning the above commands
+using the debug level ``1/10`` instead. You can check your current
+values using the admin socket and the following commands::
+
+ ceph daemon mon.FOO config show
+
+or::
+
+ ceph daemon mon.FOO config get 'OPTION_NAME'
+
+
+Reproduced the problem with appropriate debug levels. Now what?
+----------------------------------------------------------------
+
+Ideally you would send us only the relevant portions of your logs.
+We realise that figuring out the corresponding portion may not be the
+easiest of tasks. Therefore, we won't hold it to you if you provide the
+full log, but common sense should be employed. If your log has hundreds
+of thousands of lines, it may get tricky to go through the whole thing,
+specially if we are not aware at which point, whatever your issue is,
+happened. For instance, when reproducing, keep in mind to write down
+current time and date and to extract the relevant portions of your logs
+based on that.
+
+Finally, you should reach out to us on the mailing lists, on IRC or file
+a new issue on the `tracker`_.
+