From 6a28ba866d3c0cd05041d9196c3bb0e2340bd2e7 Mon Sep 17 00:00:00 2001 From: Trevor Cooper Date: Fri, 22 Jan 2016 13:27:04 -0800 Subject: Removed old lab description template and replaced with new template. Updates for ... 1) Lab description 2) POD description 3) Examples of lab tolpology and POD topology diagrams. These files were created using ideas from existing lab/POD descriptions and lab experience for rls B. (cp) provided some tidying up and random spelling fixes for the toolchain. Change-Id: I72a34be9e1c1509fd310b43562bf6d5aa1c459e7 Signed-off-by: Trevor Cooper --- docs/labs/spirent.rst | 18 ++++++++---------- 1 file changed, 8 insertions(+), 10 deletions(-) (limited to 'docs/labs/spirent.rst') diff --git a/docs/labs/spirent.rst b/docs/labs/spirent.rst index 4ec987bd..d5804ac6 100644 --- a/docs/labs/spirent.rst +++ b/docs/labs/spirent.rst @@ -1,7 +1,8 @@ Spirent Virtual Cloud Test Lab =============================== -A community provided metal resource hosted at Nephoscale, leveraged for SDN/NFV public testing and OpenDaylight, OpenStack, OPNFV projects. +A community provided metal resource hosted at Nephoscale, leveraged for SDN/NFV public testing and OpenDaylight, +OpenStack, OPNFV projects. **Spirent VCT Lab** is currently working on 3 different **OpenStack** environments each one of them deployed on different hardware configuration: @@ -22,8 +23,12 @@ There are a number of different networks referenced in the VPTC Design Blueprint These can be added or removed as specified by the test methodology. There are 8 x 10 gige SFP+ ports available on a typical C100MP used for Avalanche Layer 4-7 testing. The N4U offers 2 x 40 gige QSFP+ ports with the MX-2 Spirent Test Center Layer 2-3 testing. -There are 2 x Cumulus switches with 32 ports of 40 gige QSFP+ ports for a total capacity of 256 ports of 10 gige. We use QSFP+ to SFP+ break out cables to convert a single 40 gige port into 4 x 10 gige ports. -Together these offer a flexible solution to allow up to 8 simultaneous tests to take place with physical traffic generators at the same time. Assuming a 10 to 1 oversubscription ratio we could handle 80 community users with the current environment. +There are 2 x Cumulus switches with 32 ports of 40 gige QSFP+ ports for a total capacity of 256 ports of 10 +gige. We use QSFP+ to SFP+ break out cables to convert a single 40 gige port into 4 x 10 gige ports. +Together these offer a flexible solution to allow up to 8 simultaneous tests to take place with physical +traffic generators at the same time. Assuming a 10 to 1 oversubscription ratio we could handle 80 community +users with the current environment. + For example: * An 80 Gbps test would need 4 port pairs of 10 gige each and require 8 mission networks. @@ -32,10 +37,3 @@ For example: * Stand-alone DUT servers using STCv and AVv traffic generators could easily scale to hundreds of servers as needed. .. image:: iamges/spirent_vptc-public-drawing.png - -**Documentation tracking** - -Revision: _sha1_ - -Build date: _date_ - -- cgit 1.2.3-korg