1 files changed, 8 insertions, 4 deletions
diff --git a/docs/specification/networkconfig.rst b/docs/specification/networkconfig.rst
index 94477fc7..fa95faa5 100644
--- a/docs/specification/networkconfig.rst
+++ b/docs/specification/networkconfig.rst
@@ -9,9 +9,12 @@ Networking
**Network Hardware**
* 24 or 48 Port TOR Switch
- * NICs - Combination of 1GE and 10GE based on network topology options (per server can be on-board or use PCI-e)
- * Connectivity for each data/control network is through a separate NIC. This simplifies Switch Management however requires more NICs on the server and also more switch ports
- * BMC (Baseboard Management Controller) for lights-out mangement network using IPMI (Intelligent Platform Management Interface)
+ * NICs - Combination of 1GE and 10GE based on network topology options (per server can be on-board
+ or use PCI-e)
+ * Connectivity for each data/control network is through a separate NIC. This
+ simplifies Switch Management however requires more NICs on the server and also more switch ports
+ * BMC (Baseboard Management Controller) for lights-out mangement network using IPMI (Intelligent
+ Platform Management Interface)
**Network Options**
@@ -31,7 +34,8 @@ Networking
* Option III: 2x1G Control, 2x10G Data, 2x10G Storage, 24 Port Switch
* Data NIC used for VNF traffic
- * Storage NIC used for control plane and Storage segmented through VLANs (separate host traffic from VNF)
+ * Storage NIC used for control plane and Storage segmented through VLANs (separate host traffic
+ from VNF)
* 1 x 1G for lights-out mangement
* 1 x 1G for Admin/PXE boot