summaryrefslogtreecommitdiffstats
path: root/docs/labs/ZTE.rst
diff options
context:
space:
mode:
Diffstat (limited to 'docs/labs/ZTE.rst')
-rw-r--r--docs/labs/ZTE.rst238
1 files changed, 0 insertions, 238 deletions
diff --git a/docs/labs/ZTE.rst b/docs/labs/ZTE.rst
deleted file mode 100644
index e2348216..00000000
--- a/docs/labs/ZTE.rst
+++ /dev/null
@@ -1,238 +0,0 @@
-ZTE OPNFV Testlab
-==================================================
-
-Overview
-------------------
-
-ZTE is hosting an OPNFV testlab at Nanjing facility. The testlab would host baremetal servers for
-the use of OPNFV community as part of the OPNFV Pharos Project.
-
-The ZTE Testlab consists of 1 POD
- * POD for Fuel
-
-.. image:: images/ZTE_Overview.jpg
- :alt: ZTE OPNFV Testlab Overview
-
-The POD consists of 8 servers that consist of
- * 3 Servers for Control Nodes
- * 3 Servers for Compute Nodes
- * 2 Servers for spare
-
-
-Hardware details
------------------
-
-
-**POD-Fuel**
-
-The specifications for the servers within POD can be found below:
-
-+------------------+------------+-----------+-----------+---------------------+--------+
-| Hostname | Model | Memory | Storage | Processor | Socket |
-+------------------+------------+-----------+-----------+---------------------+--------+
-| Fuel Jump Server | ZTE R4300 | 32 GB | 600GB HDD | Intel Xeon E5-2680 | 2 |
-+------------------+------------+-----------+-----------+---------------------+--------+
-| Node4 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 |
-+------------------+------------+-----------+-----------+---------------------+--------+
-| Node5 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 |
-+------------------+------------+-----------+-----------+---------------------+--------+
-| Node6 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 |
-+------------------+------------+-----------+-----------+---------------------+--------+
-| Node10 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 |
-+------------------+------------+-----------+-----------+---------------------+--------+
-| Node11 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 |
-+------------------+------------+-----------+-----------+---------------------+--------+
-| Node12 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 |
-+------------------+------------+-----------+-----------+---------------------+--------+
-| Node13 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 |
-+------------------+------------+-----------+-----------+---------------------+--------+
-| Node14 | ZTE E9000 | 128 GB | 600GB HDD | Intel Xeon E5-2680 | 2 |
-+------------------+------------+-----------+-----------+---------------------+--------+
-
-The specifications for the Network Interfaces of servers within POD can be seen below:
-
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| Hostname | NIC Model | Ports | MAC | BW | Roles |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| Fuel Jump | 1, RTL8111/8168/8411 | enp8s0 | 98:f5:37:e1:b4:1b | 10G | mgmt |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | enp9s0 | 98:f5:37:e1:b4:1c | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 2, Inel 82599 | enp3s0f0 | 90:e2:ba:8b:08:64 | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | enp3s0f1 | 90:e2:ba:8b:08:65 | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| Node10 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:18 | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth1 | 4c:09:b4:b1:de:19 | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:1a | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth3 | 4c:09:b4:b1:de:1b | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:d8 | 10G | Admin/mgmt |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth5 | 4c:09:b4:b2:59:d9 | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| Node11 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:3c | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth1 | 4c:09:b4:b1:de:3d | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:3e | 10G | Storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth3 | 4c:09:b4:b1:de:3f | 10G | Storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 3, Intel I350 | eth4 | 4c:09:b4:b2:5a:d4 | 10G | Admin/mgmt |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth5 | 4c:09:b4:b2:5a:d5 | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| Node12 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:08 | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth1 | 4c:09:b4:b1:de:09 | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:0a | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth3 | 4c:09:b4:b1:de:0b | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:bd | 10G | Admin/mgmt |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth5 | 4c:09:b4:b2:59:be | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| Node4 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:1c | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth1 | 4c:09:b4:b1:de:1d | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:1e | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth3 | 4c:09:b4:b1:de:1f | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:a2 | 10G | Admin/mgmt |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth5 | 4c:09:b4:b2:59:a3 | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| Node5 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:24 | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth1 | 4c:09:b4:b1:de:25 | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:26 | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth3 | 4c:09:b4:b1:de:27 | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:ab | 10G | Admin/mgmt |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth5 | 4c:09:b4:b2:59:ac | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| Node6 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:40 | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth1 | 4c:09:b4:b1:de:41 | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:42 | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth3 | 4c:09:b4:b1:de:43 | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:fc | 10G | Admin/mgmt |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth5 | 4c:09:b4:b2:59:fd | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| Node13 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:38 | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth1 | 4c:09:b4:b1:de:39 | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:3a | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth3 | 4c:09:b4:b1:de:3b | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:87 | 10G | Admin/mgmt |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth5 | 4c:09:b4:b2:59:88 | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| Node14 | 1, Intel 82599 | eth0 | 4c:09:b4:b1:de:48 | 10G | Public |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth1 | 4c:09:b4:b1:de:49 | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 2, Intel 82599 | eth2 | 4c:09:b4:b1:de:4a | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth3 | 4c:09:b4:b1:de:4b | 10G | storage |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | 3, Intel I350 | eth4 | 4c:09:b4:b2:59:75 | 10G | Admin/mgmt |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-| | | eth5 | 4c:09:b4:b2:59:76 | 10G | Unused |
-+-----------+-----------------------+----------+-------------------+-----+------------+
-
-
-Software
----------
-
-The Jump servers in the Testlab are pre-provisioned with the following software:
-
- * Fuel-Jump Server:
- 1. OS: CentOS
- 2. Preprovisoned softwares: KVM, VNC server
-
-
-
-Networks
-----------
-
-**Subnet allocations**
-
-+----------------+--------------+----------------+-------------+----------+
-| Network name | Address | Mask | Gateway | VLAN id |
-+----------------+--------------+----------------+-------------+----------+
-| Public | 172.10.0.0 | 255.255.255.0 | 172.10.0.1 | Untagged |
-+----------------+--------------+----------------+-------------+----------+
-| Fuel Admin | 192.168.0.0 | 255.255.255.0 | 192.168.0.1 | Untagged |
-+----------------+--------------+----------------+-------------+----------+
-| Fuel Mangement | 192.168.11.0 | 255.255.255.0 | | 101 |
-+----------------+--------------+----------------+-------------+----------+
-| Fuel Storage | 192.168.12.0 | 255.255.255.0 | | 102 |
-+----------------+--------------+----------------+-------------+----------+
-
-
-**Lights out Network**
-
-**POD**
-
-All nodes can log in by jumpserver.
-
-+-----------+-------------------------+-------------------+----------+----------+
-| Hostname | Lights-out address | MAC | Username | Password |
-+-----------+-------------------------+-------------------+----------+----------+
-| Fuel-Jump | 58.213.14.182:5902(ssh) | 90:e2:ba:8b:08:65 | opnfv | |
-+-----------+-------------------------+-------------------+----------+----------+
-| Node4 | 192.168.0.7 | 06:9d:69:13:5f:45 | | |
-+-----------+-------------------------+-------------------+----------+----------+
-| Node5 | 192.168.0.8 | 32:9b:c4:da:10:4c | | |
-+-----------+-------------------------+-------------------+----------+----------+
-| Node6 | 192.168.0.6 | 46:18:c4:74:cf:40 | | |
-+-----------+-------------------------+-------------------+----------+----------+
-| Node10 | 192.168.0.4 | be:d0:49:d4:06:42 | | |
-+-----------+-------------------------+-------------------+----------+----------+
-| Node11 | 192.168.0.3 | a2:d5:c1:bb:2b:49 | | |
-+-----------+-------------------------+-------------------+----------+----------+
-| Node12 | 192.168.0.2 | 62:08:00:cd:4c:43 | | |
-+-----------+-------------------------+-------------------+----------+----------+
-| Node13 | 192.168.0.9 | 4c:09:b4:b2:59:87 | | |
-+-----------+-------------------------+-------------------+----------+----------+
-| Node14 | 192.168.0.10 | 9a:90:8a:db:e1:4c | | |
-+-----------+-------------------------+-------------------+----------+----------+
-
-
-Remote access infrastructure
------------------------------
-
-The ZTE OPNFV testlab is free to use for the OPNFV community.
-
-A VPN is used to provide access to the ZTE Testlab. Details can be found in *ZTE OPNFV-lab Access*
-document (Attach link)
-
-To access the Testlab, please contact Zhihui Wu(wu.zhihui1@zte.com.cn) with the following details:
- * Name
- * Organization
- * Purpose of using the lab
-
- Processing the request can take 2-3 business days.
-
- **Accessing the Jump Server**
-
- The credentials for accessing the Jump Server, please contact Zhihui Wu(wu.zhihui1@zte.com.cn).