summaryrefslogtreecommitdiffstats
diff options
context:
space:
mode:
authorNauman Ahad <Nauman_Ahad@dell.com>2015-06-08 03:22:14 +0500
committerNauman Ahad <Nauman_Ahad@dell.com>2015-06-07 22:29:04 +0000
commite078f4e147ac02a867259b854007c605266fe629 (patch)
tree8c055509c2cbd36ff0c35fe1a4cd9354ba51b04a
parentcdf8591ab56d777fd5dda23d50fffad2a0b3a677 (diff)
Updated Dell OPNFV Testlab doc
Updated Ip addresses, changed image location within directories so that they could be embedded within the document JIRA: PHAROS-14 Change-Id: I767d52913b09a6ba198a6325a1389f3660836a1f Signed-off-by: Nauman Ahad <Nauman_Ahad@dell.com>
-rw-r--r--docs/images/Dell_POD1.jpgbin185357 -> 0 bytes
-rw-r--r--docs/images/Dell_POD2.jpgbin195042 -> 0 bytes
-rw-r--r--docs/labs/Dell.rst734
-rw-r--r--docs/labs/images/Dell_Overview.jpg (renamed from docs/images/Dell_Overview.jpg)bin62317 -> 62317 bytes
-rw-r--r--docs/labs/images/Dell_POD1.jpgbin0 -> 189478 bytes
-rw-r--r--docs/labs/images/Dell_POD2.jpgbin0 -> 194546 bytes
6 files changed, 378 insertions, 356 deletions
diff --git a/docs/images/Dell_POD1.jpg b/docs/images/Dell_POD1.jpg
deleted file mode 100644
index 42e4b49e..00000000
--- a/docs/images/Dell_POD1.jpg
+++ /dev/null
Binary files differ
diff --git a/docs/images/Dell_POD2.jpg b/docs/images/Dell_POD2.jpg
deleted file mode 100644
index 4d4b92cf..00000000
--- a/docs/images/Dell_POD2.jpg
+++ /dev/null
Binary files differ
diff --git a/docs/labs/Dell.rst b/docs/labs/Dell.rst
index 44d453a9..c0c47506 100644
--- a/docs/labs/Dell.rst
+++ b/docs/labs/Dell.rst
@@ -1,356 +1,378 @@
-Dell OPNFV Testlab
-==================================================
-
-Overview
-------------------
-
-Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project.
-
-The Dell Testlab consists of 2 PODs
- * POD1 for Fuel
- * POD2 for Foreman
-
-.. image:: images/Dell_Overview.jpg
- :alt: Dell OPNFV Testlab Overview
-
-Each of the 2 PODs consists of 6 servers that consist of
- * 1 Jump Server
- * 3 Servers for Control Nodes
- * 2 Servers for Compute Nodes
-
-
-Hardware details
------------------
-
-
-**POD1-Fuel**
-
-The specifications for the servers within POD1 can be found below:
-
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-| Hostname | Model | Memory | Storage | Processor | Socket |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Fuel Jump Server | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Node2 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Node3 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Node4 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Node5 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Node6 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-
-The specifications for the Network Interfaces of servers within POD1 can be seen below:
-
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-| Hostname | NIC Model | Ports| MAC | BW | Roles |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-|Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public |
-| | +------+-------------------+-------+----------------------------------+
-| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage |
-| +----------------------------------------------+------+-------------------+-------+----------------------------------+
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused |
-| | +------+-------------------+-------+----------------------------------+
-| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused |
-+---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
-
-
-
-**POD2-Foreman**
-
-The specifications for the servers within POD2 can be found below:
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-| Hostname | Model | Memory | Storage | Processor | Socket |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Foreman Jump Server | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Node7 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Node8 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Node9 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Node11 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-|Node12 | Dell PowerEdge M620| 64 GB |600GB HDD |Intel Xeon E5-2640 | 2 |
-+---------------------+---------------------+----------------+--------------+---------------------+------------+
-
-
-The specifications for the Network Interfaces of the servers within POD2 can be seen below:
-+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+
-| Hostname | NIC Model | Ports| MAC | BW | Roles |
-+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+
-|Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:1D| 10G | Foreman Admin |
-| | +------+-----------------+-------+----------------------------------+
-| | | em2 |A4:1F:72:11:B5:20| 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:21| 10G | Public |
-| | +------+-----------------+-------+----------------------------------+
-| | | p3p2 |A4:1F:72:11:B5:23| 10G | Unused |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 3, TBD | p1p1 |A4:1F:72:11:B4:89| 10G | Unused |
-| | +------+-----------------+-------+----------------------------------+
-| | | p1p2 |A4:1F:72:11:B4:8B| 10G | Unused |
-+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+
-|Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:CF| 10G | Foreman Admin |
-| | +------+-----------------+-------+----------------------------------+
-| | | em2 |A4:1F:72:11:B4:D2| 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:D3| 10G | Public |
-| | +------+-----------------+-------+----------------------------------+
-| | | p3p2 |A4:1F:72:11:B4:D5| 10G | Unused |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 |A4:1F:72:11:B4:D7| 10G | Unused |
-| | +------+-----------------+-------+----------------------------------+
-| | | p1p2 |A4:1F:72:11:B4:DA| 10G | Unused |
-+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+
-|Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:DC| 10G | Foreman Admin |
-| | +------+-----------------+-------+----------------------------------+
-| | | em2 |A4:1F:72:11:B4:DF| 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:E0| 10G | Public |
-| | +------+-----------------+-------+----------------------------------+
-| | | p3p2 |A4:1F:72:11:B4:E2| 10G | Unused |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 3, Broadcom NetXtreme II BCM57810 | p1p1 |A4:1F:72:11:B4:E4| 10G | Unused |
-| | +------+-----------------+-------+----------------------------------+
-| | | p1p2 |A4:1F:72:11:B4:E7| 10G | Unused |
-+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+
-|Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B4:E9| 10G | Foreman Admin |
-| | +------+-----------------+-------+----------------------------------+
-| | | em2 |A4:1F:72:11:B4:EC| 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B4:ED| 10G | Public |
-| | +------+-----------------+-------+----------------------------------+
-| | | p3p2 |A4:1F:72:11:B4:EF| 10G | Unused |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 |A4:1F:72:11:B4:F1| 10G | Unused |
-| | +------+-----------------+-------+----------------------------------+
-| | | p1p2 |A4:1F:72:11:B4:F3| 10G | Unused |
-+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+
-|Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:03| 10G | Foreman Admin |
-| | +------+-----------------+-------+----------------------------------+
-| | | em2 |A4:1F:72:11:B5:06| 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:07| 10G | Public |
-| | +------+-----------------+-------+----------------------------------+
-| | | p3p2 |A4:1F:72:11:B5:09| 10G | Unused |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 3, Intel 82599 | p1p1 |A4:1F:72:11:B5:0B| 10G | Unused |
-| | +------+-----------------+-------+----------------------------------+
-| | | p1p2 |A4:1F:72:11:B5:0D| 10G | Unused |
-+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+
-|Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 |A4:1F:72:11:B5:10| 10G | Foreman Admin |
-| | +------+-----------------+-------+----------------------------------+
-| | | em2 |A4:1F:72:11:B5:13| 10G | Foreman Private/ Storage |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 2, Intel 82599 | p3p1 |A4:1F:72:11:B5:14| 10G | Public |
-| | +------+-----------------+-------+----------------------------------+
-| | | p3p2 |A4:1F:72:11:B5:16| 10G | Unused |
-| +----------------------------------------------+------+-----------------+-------+----------------------------------+
-| | 3, TBD | p1p1 |A4:1F:72:11:B4:89| 10G | Unused |
-| | +------+-----------------+-------+----------------------------------+
-| | | p1p2 |A4:1F:72:11:B4:8B| 10G | Unused |
-+---------------------+----------------------------------------------+------+-----------------+-------+----------------------------------+
-
-
-
-
-
-
-Software
----------
-
-The Jump servers in the Testlab are pre-provisioned with the following software:
-
- * Fuel-Jump Server:
- 1. OS: Ubuntu 14.04
- 2. Preprovisoned softwares: KVM, VNC server
-
-
- * Foreman-Jump Server:
- 1. OS: Provisioned with CentOS7
-
-
-
-
-
-Networks
-----------
-
-
-**POD1-Foreman Diagram**
-
-.. image:: images/Dell_POD1.jpg
- :alt: Dell POD1 Networking
-
-
-
-
-**POD2-Foreman Diagram**
-
-.. image:: images/Dell_POD2.jpg
- :alt: Dell POD2 Networking
-
-
-
-
-**Subnet allocations**
-
-+-------------------+----------------+-------------------+---------------+----------+
-| Network name | Address | Mask | Gateway | VLAN id |
-+-------------------+----------------+-------------------+---------------+----------+
-| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-| Public | 172.18.0.0 | 255.255.255.0 | 172.18.0.1 | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-|Fuel Admin |10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged |
-+-------------------+----------------+-------------------+---------------+----------+
-|Fuel Mangement |192.168.0.0 | 255.255.255.0 |192.168.0.1 | 101 |
-+-------------------+----------------+-------------------+---------------+----------+
-|Fuel Storage |192.168.1.0 | 255.255.255.0 |192.168.1.1 | 102 |
-+-------------------+----------------+-------------------+---------------+----------+
-
-
-**Lights out Network**
-
-**POD1**
-
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Hostname | Lights-out address | MAC |Username | Password |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Fuel-Jump | 172.18.1.101 |A4:1F:72:11:B4:80 | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Node2 | 172.18.1.102 |A4:1F:72:11:B4:8D | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Node3 | 172.18.1.103 |A4:1F:72:11:B4:9A | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Node4 | 172.18.1.104 |A4:1F:72:11:B4:A7 | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Node5 | 172.18.1.105 |A4:1F:72:11:B4:B4 | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Node6 | 172.18.1.106 |A4:1F:72:11:B4:C1 | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-
-**POD2**
-
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-| Hostname | Lights-out address | MAC |Username | Password |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Foreman-Jump | 172.18.1.113 |A4:1F:72:11:B5:1C | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Node7 | 172.18.1.107 |A4:1F:72:11:B4:CE | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Node8 | 172.18.1.108 |A4:1F:72:11:B4:DB | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Node9 | 172.18.1.109 |A4:1F:72:11:B4:E8 | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Node11 | 172.18.1.111 |A4:1F:72:11:B5:02 | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-|Node12 | 172.18.1.112 |A4:1F:72:11:B5:0F | root | calvin |
-+----------------+-------------------------------+------------------+---------------------+---------------------+
-
-
-
-
-
-
-
-
-
-Remote access infrastructure
------------------------------
-
-The Dell OPNFV testlab is free to use for the OPNFV community.
-
-A VPN is used to provide access to the Dell Testlab. Details can be found in *Dell OPNFV-lab Access* document (Attach link)
-
-To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details:
- * Name
- * Organization
- * Purpose of using the lab
-
- Processing the request can take 2-3 business days.
-
- **Accessing the Jump Server**
-
- The credentials for accessing the Jump servers are:
-
- *Fuel-Jump*
-
- User: opnfv
- password: d3ll1234
-
- *Foreman-Jump*
-
- User: root
- password: d3ll1234
+Dell OPNFV Testlab
+==================================================
+
+Overview
+------------------
+
+Dell is hosting an OPNFV testlab at its Santa Clara facility. The testlab would host baremetal servers for the use of OPNFV community as part of the OPNFV Pharos Project
+
+
+The Dell Testlab consists of 2 PODs
+ * POD1 for Fuel
+ * POD2 for Foreman
+
+.. image:: images/Dell_Overview.jpg
+ :height: 553
+ :width: 449
+ :alt: Dell Testlab Overiew
+ :align: left
+
+Each of the 2 PODs consists of 6 servers that consist of
+ * 1 Jump Server
+ * 3 Servers for Control Nodes
+ * 2 Servers for Compute Nodes
+
+
+
+Hardware details
+-----------------
+
+All the servers within the two PODs reside within a single Dell PowerEdge 620 chassis and have the following specifications:
+
+
+
+**POD1-Fuel**
+
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Hostname | Model | Memory | Storage | Processor | Socket |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Fuel Jump Server | Dell PowerEdge M620 | 64 GB | 1200GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node2 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node3 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node4 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node5 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node6 | Dell PowerEdge M620 | 64 GB | 600GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+
+
+
+
+**POD2-Foreman**
+
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Hostname | Model | Memory | Storage | Processor | Socket |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Foreman Jump Server | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node7 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node8 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node9 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node11 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+| Node12 | Dell PowerEdge M620 | 64 GB | 300GB HDD | Intel Xeon E5-2640 | 2 |
++---------------------+----------------------+----------------+--------------+---------------------+------------+
+
+
+
+
+
+Software
+---------
+
+The Jump servers in the Testlab are pre-provisioned with the following softwares:
+
+ * Fuel-Jump Server:
+
+ 1. OS: Ubuntu 14.04
+
+
+ * Foreman-Jump Server:
+
+ 1. OS: CentOS7
+
+
+
+
+
+Networks
+----------
+
+
+
+**POD1-Fuel**
+
+.. image:: images/Dell_POD1.jpg
+ :height: 647
+ :width: 821
+ :alt: POD1-Fuel Overview
+ :align: left
+
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Hostname | NIC Model | Ports|MAC | BW | Roles |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Fuel Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:81 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:84 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:85 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:87 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node2 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:8E | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:91 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:92 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:94 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:96 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:98 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node3 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:9B | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:9E | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:9F | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:A1 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:A3 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:A5 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node4 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:A8 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:AB | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:AC | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:AE | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:B0 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:B1 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node5 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:B5 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:B8 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:B9 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:BB | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:BD | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:C0 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node6 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:C2 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:C5 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:C6 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:C8 | 10G | Fuel Admin/mgmt/pvt/ storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:CA | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:CD | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+
+
+
+**POD2-Foreman**
+
+.. image:: images/Dell_POD2.jpg
+ :height: 721
+ :width: 785
+ :alt: POD2-Foreman Overview
+ :align: left
+
+
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Hostname | NIC Model | Ports|MAC | BW | Roles |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Foreman Jump | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:1D | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:20 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:21 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:23 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node7 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:CF | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:D2 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:D3 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:D5 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:D7 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:DA | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node8 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:DC | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:DF | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:E0 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:E2 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Broadcom NetXtreme II BCM57810 | p1p1 | A4:1F:72:11:B4:E4 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:E7 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node9 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B4:E9 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B4:EC | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B4:ED | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B4:EF | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B4:F1 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:F3 | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node11 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:03 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:06 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:07 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:09 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, Intel 82599 | p1p1 | A4:1F:72:11:B5:0B | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B5:0D | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+| Node12 | 1, Broadcom NetXtreme II BCM57810 | em1 | A4:1F:72:11:B5:10 | 10G | Foreman Admin |
+| | +------+-------------------+-------+----------------------------------+
+| | | em2 | A4:1F:72:11:B5:13 | 10G | Foreman Private/ Storage |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 2, Intel 82599 | p3p1 | A4:1F:72:11:B5:14 | 10G | Public |
+| | +------+-------------------+-------+----------------------------------+
+| | | p3p2 | A4:1F:72:11:B5:16 | 10G | Unused |
+| +----------------------------------------------+------+-------------------+-------+----------------------------------+
+| | 3, TBD | p1p1 | A4:1F:72:11:B4:89 | 10G | Unused |
+| | +------+-------------------+-------+----------------------------------+
+| | | p1p2 | A4:1F:72:11:B4:8B | 10G | Unused |
++---------------------+----------------------------------------------+------+-------------------+-------+----------------------------------+
+
+
+
+
+
+
+**Subnet allocations**
+
++-------------------+----------------+-------------------+---------------+----------+
+| Network name | Address | Mask | Gateway | VLAN id |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Admin | 10.20.0.0 | 255.255.0.0 | 10.20.0.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Mangement | 192.168.0.0 | 255.255.255.0 | 192.168.0.1 | 101 |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Storage | 192.168.1.0 | 255.255.255.0 | 192.168.1.1 | 102 |
++-------------------+----------------+-------------------+---------------+----------+
+| Fuel Public | 172.18.0.64 | 255.255.255.192 | 172.18.0.65 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Admin | 10.4.14.0 | 255.255.255.0 | 10.4.14.100 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Private | 10.4.5.0 | 255.255.255.0 | 10.4.5.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Foreman Public | 172.18.0.0 | 255.255.255.192 | 172.18.0.1 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+| Lights Out | 172.18.0.128 | 255.255.255.128 | 172.18.0.129 | Untagged |
++-------------------+----------------+-------------------+---------------+----------+
+
+
+**Lights out Network**
+
+**POD1**
+
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Hostname | Lights-out address | MAC | Username | Password |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Fuel-Jump | 172.18.1.131 | A4:1F:72:11:B4:80| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node2 | 172.18.1.132 | A4:1F:72:11:B4:8D| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node3 | 172.18.1.133 | A4:1F:72:11:B4:9A| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node4 | 172.18.1.134 | A4:1F:72:11:B4:A7| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node5 | 172.18.1.135 | A4:1F:72:11:B4:B4| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node6 | 172.18.1.136 | A4:1F:72:11:B4:C1| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+
+**POD2**
+
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Hostname | Lights-out address | MAC | Username | Password |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Foreman-Jump | 172.18.1.143 | A4:1F:72:11:B5:1C| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node7 | 172.18.1.137 | A4:1F:72:11:B4:CE| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node8 | 172.18.1.138 | A4:1F:72:11:B4:DB| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node9 | 172.18.1.139 | A4:1F:72:11:B4:E8| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node11 | 172.18.1.141 | A4:1F:72:11:B5:02| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+| Node12 | 172.18.1.142 | A4:1F:72:11:B5:0F| root | calvin |
++----------------+-------------------------------+------------------+---------------------+---------------------+
+
+
+
+
+
+
+Remote access infrastructure
+-----------------------------
+
+The Dell OPNFV testlab is free to use for the OPNFV community.
+
+A VPN is used to provide access to the Dell Testlab.
+
+To access the Testlab, please contact Waqas_Riaz@DELL.com with the following details:
+ * Name
+ * Email
+ * Designation
+ * Organization
+ * Purpose of using the lab
+
+ Processing the request can take 2-3 business days.
+
+*Accessing the Teslab*
+-----------------------
+
+* POD1 JumpServer
+
+ IP: 172.18.0.67
+
+ User: opnfv
+
+ Passwd: d3ll1234
+
+
+
+* POD2 JumpServer
+
+ IP: 172.18.0.11
+
+ User: opnfv
+
+ Passwd: d3ll1234
+
diff --git a/docs/images/Dell_Overview.jpg b/docs/labs/images/Dell_Overview.jpg
index 5a288a81..5a288a81 100644
--- a/docs/images/Dell_Overview.jpg
+++ b/docs/labs/images/Dell_Overview.jpg
Binary files differ
diff --git a/docs/labs/images/Dell_POD1.jpg b/docs/labs/images/Dell_POD1.jpg
new file mode 100644
index 00000000..d88549ba
--- /dev/null
+++ b/docs/labs/images/Dell_POD1.jpg
Binary files differ
diff --git a/docs/labs/images/Dell_POD2.jpg b/docs/labs/images/Dell_POD2.jpg
new file mode 100644
index 00000000..9f1af3ce
--- /dev/null
+++ b/docs/labs/images/Dell_POD2.jpg
Binary files differ