From 7d501c4ea14ca3f6294798e010b68395b99aa70b Mon Sep 17 00:00:00 2001 From: Georg Kunz Date: Wed, 15 Feb 2017 11:01:42 +0100 Subject: Adding template framework for Danube documentation Change-Id: I0960f3538163e2609db9a196d665f148967ab454 Signed-off-by: Georg Kunz --- docs/release/configguide/featureconfig.rst | 32 +++ docs/release/configguide/index.rst | 12 ++ docs/release/configguide/postinstall.rst | 35 ++++ docs/release/installation/index.rst | 11 + .../installation/installation.instruction.rst | 203 ++++++++++++++++++ docs/release/release-notes/index.rst | 11 + docs/release/release-notes/release-notes.rst | 233 +++++++++++++++++++++ docs/release/scenarios/os-odl-gluon-noha/index.rst | 16 ++ .../os-odl-gluon-noha/scenario.description.rst | 42 ++++ docs/release/userguide/feature.userguide.rst | 27 +++ docs/release/userguide/index.rst | 23 ++ 11 files changed, 645 insertions(+) create mode 100644 docs/release/configguide/featureconfig.rst create mode 100644 docs/release/configguide/index.rst create mode 100644 docs/release/configguide/postinstall.rst create mode 100644 docs/release/installation/index.rst create mode 100644 docs/release/installation/installation.instruction.rst create mode 100644 docs/release/release-notes/index.rst create mode 100644 docs/release/release-notes/release-notes.rst create mode 100644 docs/release/scenarios/os-odl-gluon-noha/index.rst create mode 100644 docs/release/scenarios/os-odl-gluon-noha/scenario.description.rst create mode 100644 docs/release/userguide/feature.userguide.rst create mode 100644 docs/release/userguide/index.rst (limited to 'docs/release') diff --git a/docs/release/configguide/featureconfig.rst b/docs/release/configguide/featureconfig.rst new file mode 100644 index 0000000..005fe9f --- /dev/null +++ b/docs/release/configguide/featureconfig.rst @@ -0,0 +1,32 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 + +====================== +NetReady Configuration +====================== +Add a brief introduction to configure OPNFV with this specific feature including +dependancies on platform components, this description should be at a level that +will apply to any installer providing the pre-requisite components. + +.. contents:: + :depth: 3 + :local: + +Pre-configuration activities +---------------------------- +Describe specific pre-configuration activities. This should include ensuring the +right components are installed by the installation tools as required for your +feature to function. Refer to the previous installer configuration chapters, +installations guide and release notes + +Hardware configuration +---------------------- +Describe the hardware configuration needed for this specific feature + +Feature configuration +--------------------- +Describe the procedures to configure your feature on the platform in order +that it is ready to use according to the feature instructions in the platform +user guide. Where applicable you should add content in the postinstall.rst +to validate the feature is configured for use. +(checking components are installed correctly etc...) diff --git a/docs/release/configguide/index.rst b/docs/release/configguide/index.rst new file mode 100644 index 0000000..67f4504 --- /dev/null +++ b/docs/release/configguide/index.rst @@ -0,0 +1,12 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 + +================================== +OPNFV NetReady Configuration Guide +================================== + +.. toctree:: + :maxdepth: 1 + + featureconfig + postinstall diff --git a/docs/release/configguide/postinstall.rst b/docs/release/configguide/postinstall.rst new file mode 100644 index 0000000..a1a3a2b --- /dev/null +++ b/docs/release/configguide/postinstall.rst @@ -0,0 +1,35 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 + +==================================== +NetReady Post Installation Procedure +==================================== + +Add a brief introduction to the methods of validating the installation +according to this specific installer or feature. + +.. contents:: + :depth: 3 + :local: + +Automated post installation activities +-------------------------------------- +Describe specific post installation activities performed by the OPNFV +deployment pipeline including testing activities and reports. Refer to +the relevant testing guides, results, and release notes. + +note: this section should be singular and derived from the test projects +once we have one test suite to run for all deploy tools. This is not the +case yet so each deploy tool will need to provide (hopefully very simillar) +documentation of this. + +NetReady post configuration procedures +-------------------------------------- +Describe any deploy tool or feature specific scripts, tests or procedures +that should be carried out on the deployment post install and configuration +in this section. + +Platform components validation +------------------------------ +Describe any component specific validation procedures necessary for your +deployment tool in this section. diff --git a/docs/release/installation/index.rst b/docs/release/installation/index.rst new file mode 100644 index 0000000..986056c --- /dev/null +++ b/docs/release/installation/index.rst @@ -0,0 +1,11 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 + +=========================== +OPNFV NetReady Installation +=========================== + +.. toctree:: + :maxdepth: 1 + + installation.instruction diff --git a/docs/release/installation/installation.instruction.rst b/docs/release/installation/installation.instruction.rst new file mode 100644 index 0000000..097d820 --- /dev/null +++ b/docs/release/installation/installation.instruction.rst @@ -0,0 +1,203 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 + +============================== +OPNFV Gluon Installation Guide +============================== + +This document describes how to install , it's dependencies and required system resources. + +.. contents:: + :depth: 3 + :local: + +Version history +--------------- + ++--------------------+--------------------+--------------------+--------------------+ +| **Date** | **Ver.** | **Author** | **Comment** | +| | | | | ++--------------------+--------------------+--------------------+--------------------+ +| 2015-04-14 | 0.1.0 | Jonas Bjurel | First draft | +| | | | | ++--------------------+--------------------+--------------------+--------------------+ +| | 0.1.1 | | | +| | | | | ++--------------------+--------------------+--------------------+--------------------+ +| | 1.0 | | | +| | | | | +| | | | | ++--------------------+--------------------+--------------------+--------------------+ + +Introduction +------------ + + +: + +This document describes the supported software and hardware configurations for the +Fuel OPNFV reference platform as well as providing guidelines on how to install and +configure such reference system. + +Although the available installation options gives a high degree of freedom in how the system is set-up, +with what architecture, services and features, etc., not nearly all of those permutations provides +a OPNFV compliant reference architecture. Following the guidelines in this document ensures +a result that is OPNFV compliant. + +The audience of this document is assumed to have good knowledge in network and Unix/Linux administration. + +Preface +------- + + +: + +Before starting the installation of Fuel@OPNFV, some planning must preceed. + +First of all, the Fuel@OPNFV .iso image needs to be retrieved, +the Latest stable Arno release of Fuel@OPNFV can be found here: + +Alternatively, you may build the .iso from source by cloning the opnfv/genesis git repository: +@gerrit.opnf.org/gerrit/genesis> +Check-out the Arno release: + +Goto the fuel directory and build the .iso + + +Familiarize yourself with the Fuel 6.0.1 version by reading the following documents: +- abc +- def +- ghi + +Secondly, a number of deployment specific parameters must be collected, those are: + +1. Provider sub-net and gateway information + +2. Provider VLAN information + +3. Provider DNS addresses + +4. Provider NTP addresses + +This information will be needed for the configuration procedures provided in this document. + +Hardware requirements +--------------------- + + +: + +Following minimum hardware requirements must be met for installation of Fuel@OPNFV: + ++--------------------+----------------------------------------------------+ +| **HW Aspect** | **Requirement** | +| | | ++--------------------+----------------------------------------------------+ +| **# of servers** | Minimum 5 (3 for non redundant deployment) | +| | 1 Fuel deployment master (may be virtualized) | +| | 3(1) Controllers | +| | 1 Compute | ++--------------------+----------------------------------------------------+ +| **CPU** | Minimum 1 socket x86_AMD64 Ivy bridge 1.6 GHz | +| | | ++--------------------+----------------------------------------------------+ +| **RAM** | Minimum 16GB/server (Depending on VNF work load) | +| | | ++--------------------+----------------------------------------------------+ +| **Disk** | Minimum 256GB 10kRPM spinning disks | +| | | ++--------------------+----------------------------------------------------+ +| **NICs** | 2(1)x10GE Niantec for Private/Public (Redundant) | +| | | +| | 2(1)x10GE Niantec for SAN (Redundant) | +| | | +| | 2(1)x1GE for admin (PXE) and control (RabitMQ,etc) | +| | | ++--------------------+----------------------------------------------------+ + +Top of the rack (TOR) Configuration requirements +------------------------------------------------ + + +: + +The switching infrastructure provides connectivity for the OPNFV infra-structure operations as well as +for the tenant networks (East/West) and provider connectivity (North/South bound connectivity). +The switching connectivity can (but does not need to) be fully redundant, +in case it and comprises a redundant 10GE switch pair for "Traffic/Payload/SAN" purposes as well as +a 1GE switch pair for "infrastructure control-, management and administration" + +The switches are **not** automatically configured from the OPNFV reference platform. +All the networks involved in the OPNFV infra-structure as well as the provider networks +and the private tenant VLANs needs to be manually configured. + +This following sections guides through required black-box switch configurations. + +VLAN considerations and blue-print +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +IP Address plan considerations and blue-print +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +OPNFV Software installation and deployment +------------------------------------------ + + +: + +This section describes the installation of the Fuel@OPNFV installation server (Fuel master) +as well as the deployment of the full OPNFV reference platform stack across a server cluster. +Etc. + +Install Fuel master +^^^^^^^^^^^^^^^^^^^ + +Create an OPNV (Fuel Environment) +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +Configure the OPNFV environment +^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +Deploy the OPNFV environment +^^^^^^^^^^^^^^^^^^^^^^^^^^^^ + +Installation health-check +------------------------- + + +: + +Now that the OPNFV environment has been created, and before the post installation configurations is started, +perform a system health check from the Fuel GUI: + +- Select the "Health check" TAB. +- Select all test-cases +- And click "Run tests" + +All test cases except the following should pass: + +Post installation and deployment actions +---------------------------------------- + + +: +After the OPNFV deployment is completed, the following manual changes needs to be performed in order +for the system to work according OPNFV standards. + +**Change host OS password:** +Change the Host OS password by...... + +References +---------- + + +: + +OPNFV +^^^^^ + +OpenStack +^^^^^^^^^ + +OpenDaylight +^^^^^^^^^^^^ diff --git a/docs/release/release-notes/index.rst b/docs/release/release-notes/index.rst new file mode 100644 index 0000000..19bb97e --- /dev/null +++ b/docs/release/release-notes/index.rst @@ -0,0 +1,11 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 + +============================ +OPNFV NetReady Release Notes +============================ + +.. toctree:: + :maxdepth: 1 + + release-notes diff --git a/docs/release/release-notes/release-notes.rst b/docs/release/release-notes/release-notes.rst new file mode 100644 index 0000000..337e770 --- /dev/null +++ b/docs/release/release-notes/release-notes.rst @@ -0,0 +1,233 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 + +============================ +OPNFV NetReady Release Notes +============================ + +This document provides the release notes for of . + +.. contents:: + :depth: 3 + :local: + + +Version history +--------------- + ++--------------------+--------------------+--------------------+--------------------+ +| **Date** | **Ver.** | **Author** | **Comment** | +| | | | | ++--------------------+--------------------+--------------------+--------------------+ +| 2015-04-14 | 0.1.0 | Jonas Bjurel | First draft | +| | | | | ++--------------------+--------------------+--------------------+--------------------+ +| | 0.1.1 | | | +| | | | | ++--------------------+--------------------+--------------------+--------------------+ +| | 1.0 | | | +| | | | | ++--------------------+--------------------+--------------------+--------------------+ + +Important notes +--------------- + + + +: + +**Attention:** Please be aware that since LSV3 a pre-deploy script must be ran on the Fuel master - +see the OPNFV@Fuel SW installation instructions + +Summary +------- + + + +: + +Arno Fuel@OPNFV is based the OpenStack Fuel upstream project version 6.0.1, +but adds OPNFV unique components such as OpenDaylight version: Helium as well as other OPNFV unique configurations...... + +Release Data +------------ + + +: + ++--------------------------------------+--------------------------------------+ +| **Project** | E.g. Arno/genesis/fuel@opnfv | +| | | ++--------------------------------------+--------------------------------------+ +| **Repo/commit-ID** | E.g. genesis/adf634a0d4..... | +| | | ++--------------------------------------+--------------------------------------+ +| **Release designation** | E.g. Arno RC2 | +| | | ++--------------------------------------+--------------------------------------+ +| **Release date** | E.g. 2015-04-16 | +| | | ++--------------------------------------+--------------------------------------+ +| **Purpose of the delivery** | E.g. OPNFV Internal quality assurance| +| | | ++--------------------------------------+--------------------------------------+ + +Version change +^^^^^^^^^^^^^^ + +Module version changes +~~~~~~~~~~~~~~~~~~~~~~ + + +: + +- Fuel have changed from 5.1 to 6.0.1 + +- OpenDaylight has changed from Helium-SR1 to Helium-SR2 + +Document version changes +~~~~~~~~~~~~~~~~~~~~~~~~ + + +: + +- The Fuel@OPNFV installation guide version has changed from version 0.1 to to 0.2 + +Reason for version +^^^^^^^^^^^^^^^^^^ +Feature additions +~~~~~~~~~~~~~~~~~ + + +: + +**JIRA BACK-LOG:** + ++--------------------------------------+--------------------------------------+ +| **JIRA REFERENCE** | **SLOGAN** | +| | | ++--------------------------------------+--------------------------------------+ +| BGS-123 | ADD OpenDaylight ml2 integration | +| | | ++--------------------------------------+--------------------------------------+ +| BGS-456 | Add auto-deployment of Fuel@OPNFV | +| | | ++--------------------------------------+--------------------------------------+ + +Bug corrections +~~~~~~~~~~~~~~~ + +**JIRA TICKETS:** + ++--------------------------------------+--------------------------------------+ +| **JIRA REFERENCE** | **SLOGAN** | +| | | ++--------------------------------------+--------------------------------------+ +| BGS-888 | Fuel doesn't deploy | +| | | ++--------------------------------------+--------------------------------------+ +| BGS-999 | Floating IP doesn't work | +| | | ++--------------------------------------+--------------------------------------+ + +Deliverables +------------ + +Software deliverables +^^^^^^^^^^^^^^^^^^^^^ + + + +: + +Documentation deliverables +^^^^^^^^^^^^^^^^^^^^^^^^^^ + + + +: + +Known Limitations, Issues and Workarounds +----------------------------------------- + +System Limitations +^^^^^^^^^^^^^^^^^^ + + +: + +**Max number of blades:** 1 Fuel master, 3 Controllers, 20 Compute blades + +**Min number of blades:** 1 Fuel master, 1 Controller, 1 Compute blade + +**Storage:** Ceph is the only supported storage configuration. + +**Max number of networks:** 3800 (Needs special switch config.) + +**L3Agent:** L3 agent and floating IPs is not supported. + +Known issues +^^^^^^^^^^^^ + + +: + +**JIRA TICKETS:** + ++--------------------------------------+--------------------------------------+ +| **JIRA REFERENCE** | **SLOGAN** | +| | | ++--------------------------------------+--------------------------------------+ +| BGS-987 | Nova-compute process does | +| | not re-spawn when killed | +| | | ++--------------------------------------+--------------------------------------+ +| BGS-654 | MOS 5.1 : neutron net-list returns | +| | "400 Bad request" | +| | | ++--------------------------------------+--------------------------------------+ + +Workarounds +^^^^^^^^^^^ + + + +: + +- In case the contact with a compute is lost - restart the compute host +- In case the disk is full on a controller - delete all files in /tmp + +Test Result +----------- + + +: + +Fuel@OPNFV Arno RC2 has undergone QA test runs with the following results: + ++--------------------------------------+--------------------------------------+ +| **TEST-SUITE** | **Results:** | +| | | ++--------------------------------------+--------------------------------------+ +| Tempest test suite 123 | Following tests failed: | +| | | +| | 1. Image resizing.... | +| | | +| | 2. Heat deploy.... | ++--------------------------------------+--------------------------------------+ +| Robot test suite 456 | Following tests failed: | +| | | +| | 1....... | +| | | +| | 2....... | ++--------------------------------------+--------------------------------------+ + +References +---------- + + +: + +For more information on the OPNFV Danube release, please see: + +http://opnfv.org/danube diff --git a/docs/release/scenarios/os-odl-gluon-noha/index.rst b/docs/release/scenarios/os-odl-gluon-noha/index.rst new file mode 100644 index 0000000..ae99305 --- /dev/null +++ b/docs/release/scenarios/os-odl-gluon-noha/index.rst @@ -0,0 +1,16 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) + +================= +os-odl-gluon-noha +================= +.. This document will be used to provide a description of the scenario for an end user. +.. You should explain the purpose of the scenario, the types of capabilities provided and +.. the unique components that make up the scenario including how they are used. + +.. toctree:: + :maxdepth: 1 + + scenario.description + diff --git a/docs/release/scenarios/os-odl-gluon-noha/scenario.description.rst b/docs/release/scenarios/os-odl-gluon-noha/scenario.description.rst new file mode 100644 index 0000000..7b316bb --- /dev/null +++ b/docs/release/scenarios/os-odl-gluon-noha/scenario.description.rst @@ -0,0 +1,42 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) + +======================= +OPNFV os-odl-gluon-noha +======================= + +This document provides scenario level details for the Danube release of Gluon. + +.. contents:: + :depth: 3 + :local: + +Introduction +------------ +.. In this section explain the purpose of the scenario and the types of capabilities provided + +Scenario components and composition +----------------------------------- +.. In this section describe the unique components that make up the scenario, +.. what each component provides and why it has been included in order +.. to communicate to the user the capabilities available in this scenario. + +Scenario usage overview +----------------------- +.. Provide a brief overview on how to use the scenario and the features available to the +.. user. This should be an "introduction" to the userguide document, and explicitly link to it, +.. where the specifics of the features are covered including examples and API's + +Limitations, Issues and Workarounds +----------------------------------- +.. Explain scenario limitations here, this should be at a design level rather than discussing +.. faults or bugs. If the system design only provide some expected functionality then provide +.. some insight at this point. + +References +---------- + +For more information on the OPNFV Danube release, please visit +http://www.opnfv.org/danube + diff --git a/docs/release/userguide/feature.userguide.rst b/docs/release/userguide/feature.userguide.rst new file mode 100644 index 0000000..69236c6 --- /dev/null +++ b/docs/release/userguide/feature.userguide.rst @@ -0,0 +1,27 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) + +========================= +OPNFV NetReady User Guide +========================= + +.. contents:: + :depth: 3 + :local: + +Gluon description +----------------- +.. Describe the specific features and how it is realised in the scenario in a brief manner +.. to ensure the user understand the context for the user guide instructions to follow. + +Gluon capabilities and usage +---------------------------- +.. Describe the specific capabilities and usage for feature. +.. Provide enough information that a user will be able to operate the feature on a deployed scenario. + +Gluon API guidelines and examples +--------------------------------- +.. Describe with examples how to use specific features, provide API examples and details required to +.. operate the feature on the platform. + diff --git a/docs/release/userguide/index.rst b/docs/release/userguide/index.rst new file mode 100644 index 0000000..5fec000 --- /dev/null +++ b/docs/release/userguide/index.rst @@ -0,0 +1,23 @@ +.. This work is licensed under a Creative Commons Attribution 4.0 International License. +.. http://creativecommons.org/licenses/by/4.0 +.. (c) + +===================== + User Guide +===================== + +.. The feature user guide should provide an OPNFV user with enough information to +.. use the features provided by the feature project in the supported scenarios. +.. This guide should walk a user through the usage of the features once a scenario +.. has been deployed and is active according to the installation guide provided +.. by the installer project. + +.. toctree:: + :maxdepth: 1 + + feature.userguide +.. The feature.userguide.rst file should contain the text for this document +.. additional documents can be added to this directory and added in the right order +.. to this file as a list below. + + -- cgit 1.2.3-korg