=============================================================================================================
OPNFV Installation instruction for the Brahmaputra WP1 release of OPNFV when using Fuel as a deployment tool
=============================================================================================================
.. contents:: Table of Contents
:backlinks: none
Abstract
========
This document describes how to install the Brahmaputra WP1 release of
OPNFV when using Fuel as a deployment tool covering it's limitations,
dependencies and required system resources.
License
=======
Brahmaputra WP1 release of OPNFV when using Fuel as a deployment tool
Docs (c) by Jonas Bjurel (Ericsson AB)
Brahmaputra WP1 release of OPNFV when using Fuel as a deployment tool
Docs are licensed under a Creative Commons Attribution 4.0
International License. You should have received a copy of the license
along with this. If not, see
.
Version history
===============
+--------------------+--------------------+--------------------+--------------------+
| **Date** | **Ver.** | **Author** | **Comment** |
| | | | |
+--------------------+--------------------+--------------------+--------------------+
| 2015-06-03 | 1.0.0 | Jonas Bjurel | Installation |
| | | (Ericsson AB) | instruction for |
| | | | the Arno release |
| | | | |
| 2015-09-27 | 1.1.0 | Daniel Smith | ARNO SR1-RC1 |
| | | (Ericsson AB) | update |
| | | | |
| | | | |
| 2015-11-19 | 2.0.0 | Daniel Smith | B-Rel WP1 update |
| | | | |
+--------------------+--------------------+--------------------+--------------------+
Introduction
============
This document describes providing guidelines on how to install and
configure the Brahmaputra WP1 release of OPNFV when using Fuel as a
deployment tool including required software and hardware
configurations.
Although the available installation options gives a high degree of
freedom in how the system is set-up including architecture, services
and features, etc. said permutations may not provide an OPNFV
compliant reference architecture. This instruction provides a
step-by-step guide that results in an OPNFV Brahmaputra WP1 compliant
deployment.
The audience of this document is assumed to have good knowledge in
networking and Unix/Linux administration.
Preface
=======
Before starting the installation of the Brahmaputra WP1 release of
OPNFV when using Fuel as a deployment tool, some planning must be
done.
Retrieving the ISO image
------------------------
First of all, the Fuel deployment ISO image needs to be retrieved, the
.iso image of the Brahmaputra WP1 release of OPNFV when using Fuel as
a deployment tool can be found at
http://artifacts.opnfv.org/fuel/opnfv-2015-11-19_03-04-21.iso NOTE:
TO BE UPDATED WITH FINAL B-REL ARTIFACT
Building the ISO image
----------------------
Alternatively, you may build the .iso from source by cloning the
opnfv/genesis git repository. To retrieve the repository for the Arno
release use the following command:
- git clone https://@gerrit.opnf.org/gerrit/fuel
Check-out the Brahmaputra WP1 release tag to set the branch to the
baseline required to replicate the Brahmaputra WP1 release:
- TODO: NEEDS UPDATE TO REFLECT WP1 TAG / NEW REPO - cd genesis; git
checkout stable/arno2015.2.0
Go to the fuel directory and build the .iso:
- cd fuel/build; make all
For more information on how to build, please see "OPNFV Build
instructions for - Brahmaputra WP1 release of OPNFV when using Fuel as
a deployment tool which you retrieved with the repository at
Next, familiarize yourself with the Fuel 7.0 version by reading the
following documents:
- Fuel planning guide
- Fuel user guide
- Fuel operations guide
- Fuel Plugin Developers Guide
A number of deployment specific parameters must be collected, those are:
1. Provider sub-net and gateway information
2. Provider VLAN information
3. Provider DNS addresses
4. Provider NTP addresses
5. Network Topology you plan to Deploy (VLAN, GRE(VXLAN), FLAT)
6. Linux Distro you intend to deploy.
7. How many nodes and what roles you want to deploy (Controllers,
Storage, Computes)
8. Monitoring Options you want to deploy (Ceilometer, MongoDB).
9. Other options not covered in the document are available in the
links above
This information will be needed for the configuration procedures
provided in this document.
Hardware requirements
=====================
The following minimum hardware requirements must be met for the
installation of Brahmaputra WP1 using Fuel:
+--------------------+------------------------------------------------------+
| **HW Aspect** | **Requirement** |
| | |
+--------------------+------------------------------------------------------+
| **# of nodes** | Minimum 6 (3 for non redundant deployment): |
| | |
| | - 1 Fuel deployment master (may be virtualized) |
| | |
| | - 3(1) Controllers |
| | |
| | - 1 Compute |
| | |
| | - 1 Ceilometer (VM option) |
+--------------------+------------------------------------------------------+
| **CPU** | Minimum 1 socket x86_AMD64 with Virtualization |
| | support |
+--------------------+------------------------------------------------------+
| **RAM** | Minimum 16GB/server (Depending on VNF work load) |
| | |
+--------------------+------------------------------------------------------+
| **Disk** | Minimum 256GB 10kRPM spinning disks |
| | |
+--------------------+------------------------------------------------------+
| **Networks** | 4 Tagged VLANs (PUBLIC, MGMT, STORAGE, PRIVATE) |
| | |
| | 1 Un-Tagged VLAN for PXE Boot - ADMIN Network |
| | |
| | note: These can be run on single NIC - or spread out |
| | over other nics as your hardware supports |
+--------------------+------------------------------------------------------+
Help with Hardware Requirements
===============================
Calculate hardware requirements:
Refer to the OpenStack Hardware Compability List
for more information on various hardware types available for use.
When choosing the hardware on which you will deploy your OpenStack
environment, you should think about:
- CPU -- Consider the number of virtual machines that you plan
to deploy in your cloud environment and the CPU per virtual
machine.
- Memory -- Depends on the amount of RAM assigned per virtual
machine and the controller node.
- Storage -- Depends on the local drive space per virtual
machine, remote volumes that can be attached to a virtual
machine, and object storage.
- Networking -- Depends on the Choose Network Topology, the
network bandwidth per virtual machine, and network storage.
Top of the rack (TOR) Configuration requirements
================================================
The switching infrastructure provides connectivity for the OPNFV
infrastructure operations, tenant networks (East/West) and provider
connectivity (North/South bound connectivity); it also provides needed
connectivity for the storage Area Network (SAN). To avoid traffic
congestion, it is strongly suggested that three physically separated
networks are used, that is: 1 physical network for administration and
control, one physical network for tenant private and public networks,
and one physical network for SAN. The switching connectivity can (but
does not need to) be fully redundant, in such case it and comprises a
redundant 10GE switch pair for each of the three physically separated
networks.
The physical TOR switches are **not** automatically configured from
the OPNFV reference platform. All the networks involved in the OPNFV
infrastructure as well as the provider networks and the private tenant
VLANs needs to be manually configured.
Manual configuration of the Brahmaputra WP1 hardware platform should
be carried out according to the Pharos specification TODO-
OPNFV Software installation and deployment
==========================================
This section describes the installation of the OPNFV installation
server (Fuel master) as well as the deployment of the full OPNFV
reference platform stack across a server cluster.
Install Fuel master
-------------------
1. Mount the Brahmaputra WP1 ISO file as a boot device to the jump host server.
2. Reboot the jump host to establish the Fuel server.
- The system now boots from the ISO image.
- Select 'DVD Fuel Install (Static IP)'
- Press [Enter].
3. Wait until screen Fuel setup is shown (Note: This can take up to 30 minutes).
4. In the 'Fuel User' Section - Confirm/change the default password
- Enter 'admin' in the Fuel password input
- Enter 'admin' in the Confim password input
- Select 'Check' and press [Enter]
5. In 'Network Setup' Section - Configure DHCP/Static IP information
for your FUEL node - For example, ETH0 is 10.20.0.2/24 for FUEL
booting and ETH1 is DHCP in your corporate/lab network.
- Configure eth1 or other network interfaces here as well (if you
have them present on your FUEL server).
6. In 'PXE Setup' Section - Change the following fields to appropriate
values (example below):
- DHCP Pool Start 10.20.0.3
- DHCP Pool End 10.20.0.254
- DHCP Pool Gateway 10.20.0.2 (ip of Fuel node)
7. In 'DNS & Hostname' - Change the following fields to appropriate values:
- Hostname -fuel
- Domain
- Search Domain
- External DNS
- Hostname to test DNS
- Select 'Check' and press [Enter]
8. OPTION TO ENABLE PROXY SUPPORT - In 'Bootstrap Image', edit the
following fields to define a proxy.
NOTE: cannot be used in tandem with local repo support
NOTE: not tested with ODL for support (plugin)
- Navigate to 'HTTP proxy' and input your http proxy address
- Select 'Check' and press [Enter]
9. In 'Time Sync' Section - Change the following fields to appropriate values:
- NTP Server 1
- NTP Server 2
- NTP Server 3
10. Start the installation.
- Select Quit Setup and press Save and Quit.
- Installation starts, wait until a screen with logon credentials is shown.
Boot the Node Servers
---------------------
After the Fuel Master node has rebooted from the above step and is at
the login prompt, you should boot the Node Servers (Your
Compute/Control/Storage blades (nested or real)) with a PXE Booting
Scheme so that the FUEL
Master can pick them up for control.
11. Enable PXE booting
- For every controller and compute server: enable PXE Booting as
the first boot device in the BIOS boot order menu and hard disk
as the second boot device in the same menu.
12. Reboot all the control and compute blades.
13. Wait for the availability of nodes showing up in the Fuel GUI.
- Connect to the FUEL UI via the URL provided in the Console
(default: http://10.20.0.2:8000)
- Wait until all nodes are displayed in top right corner of the
Fuel GUI: TOTAL NODES and UNALLOCATED NODES.
Install ODL Plugin on FUEL node
-------------------------------
NOTE: CURRENTLY DISABLED IN B-REL WP1
14. SSH to your FUEL node (e.g. root@10.20.0.2 pwd: r00tme)
15. Verify the plugin exists at /opt/opnfv/opendaylight-0.6-0.6.1-1.noarch.rpm
16. Install the plugin with the command
- "fuel plugins --install /opt/opnfv/opendaylight-0.6-0.6.1-1.noarch.rpm"
- Expected output: "Plugin opendaylight-0.6-0.6.1-1.noarch.rpm was
successfully installed."
Create an OPNFV Environment
---------------------------
17. Connect to Fuel WEB UI with a browser towards port http://:8000 (login admin/admin)
18. Create and name a new OpenStack environment, to be installed.
19. Select and press "Next"
20. Select compute virtulization method.
- Select KVM as hypervisor (or one of your choosing) and press "Next"
18. Select network mode.
- Select Neutron with GRE segmentation and press "Next"
Note: Required if using the ODL plugin
19. Select Storage Back-ends.
- Select "Yes, use Ceph" if you intend to deploy Ceph Backends and
press "Next"
20. Select additional services you wish to install.
- Check option and press "Next"
Note: If you use Ceilometer and you only have 5 nodes, you may
have to run in a 3/1/1 (controller/ceilo-mongo/compute)
configuration. Suggest adding more compute nodes
21. Create the new environment.
- Click "Create" Button
Configure the OPNFV environment
-------------------------------
22. Enable PXE booting (if you haven't done this already)
- For every controller and compute server: enable PXE Booting as
the first boot device in the BIOS boot order menu and hard disk
as the second boot device in the same menu.
23. Wait for the availability of nodes showing up in the Fuel GUI.
- Wait until all nodes are displayed in top right corner of the
Fuel GUI: TOTAL NODES and UNALLOCATED NODES.
24. Open the environment you previously created.
25. Open the networks tab.
26. Update the Public network configuration.
Change the following fields to appropriate values:
- IP Range Start to
- IP Range End to
- CIDR to
- Check VLAN tagging.
- Set appropriate VLAN id.
- Gateway to
- Set floating ip ranges
27. Update the Storage Network Configuration
- Set CIDR to appropriate value (default 192.168.1.0/24)
- Set vlan to appropriate value (default 102)
28. Update the Management network configuration.
- Set CIDR to appropriate value (default 192.168.0.0/24)
- Check VLAN tagging.
- Set appropriate VLAN id. (default 101)
29. Update the Private Network Information
- Set CIDR to appropriate value (default 192.168.2.0/24
- Check and set VLAN tag appropriately (default 103)
30. Update the Neutron L3 configuration.
- Set Internal network CIDR to an appropriate value
- Set Internal network gateway to an appropriate value
- Set Guest OS DNS Server values appropriately
31. Save Settings.
32. Click on the "Nodes" Tab in the FUEL WEB UI.
33. Assign roles.
- Click on "+Add Nodes" button
- Check "Controller" and the "Storage-Ceph OSD" in the Assign Roles Section
- Check the 3 Nodes you want to act as Controllers from the bottom half of the screen
- Click .
- Click on "+Add Nodes" button
- Check "Compute" in the Assign Roles Section
- Check the Nodes that you want to act as Computes from the bottom half of the screen
- Click .
34. Configure interfaces.
- Check Select to select all nodes with Control, Telemetry,
MongoDB and Compute node roles.
- Click
- Screen Configure interfaces on number of nodes is shown.
- Assign interfaces (bonded) for mgmt-, admin-, private-, public-
and storage networks
Note: Set MTU level to at least MTU=1458 (recommended
MTU=1450 for SDN over VXLAN Usage) for each network if you
using ODL plugin
- Click Apply
Enable ODL
----------
TODO: NOT UPDATED YET FOR WP1 - NOT AVAILABLE AT TIME OF EDIT
35. In the FUEL UI of your Enviornment, click the "Settings" Tab
- Enable OpenStack debug logging (in the Common Section) - optional
- Check the OpenDaylight Lithium Plugin Section
- Check to enable VXLAN
- Modify VNI and Port Range if desired
- Click "Save Settings" at the bottom to Save.
OPTIONAL - Set Local Mirror Repos
---------------------------------
The following steps can be executed if you are in an environment with
no connection to the internet. The Fuel server delivers a local repo
that can be used for installation / deployment of openstack.
36. In the Fuel UI of your Environment, click the Settings Tab and
scroll to the Repositories Section.
- Replace the URI values for the "Name" values outlined below:
- "ubuntu" URI="deb http://:8080/ubuntu-part trusty main"
- "ubuntu-security" URI="deb
http://:8080/ubuntu-part trusty main"
- "ubuntu-updates" URI="deb
http://:8080/ubuntu-part trusty main"
- "mos-updates" URI="deb
http://:8080/mos-ubuntu mos6.1-updates main
restricted"
- "mos-security" URI="deb
http://:8080/mos-ubuntu mos6.1-security main
restricted"
- "mos-holdback" URI="deb
http://:8080/mos-ubuntu mos6.1-holdback main
restricted"
- Click "Save Settings" at the bottom to Save your changes
Verify Networks
---------------
Its is important that Verify Networks be done as it will ensure that
you can not only communicate on the networks you have setup, but can
fetch the packages needed for a succesful deployment.
37. From the FUEL UI in your Environment, Select the Networks Tab
- At the bottom of the page, Select "Verify Networks"
- Continue to fix your topology (physical switch, etc) until the
"Verification Succeeded - Your network is configured correctly"
message is shown
Deploy Your Environment
-----------------------
38. Deploy the environment.
In the Fuel GUI, click on the Dashboard Tab.
- Click on 'Deploy Changes' in the 'Ready to Deploy?' Section
- Examine any information notice that pops up and click 'Deploy'
Wait for your deployment to complete, you can view the 'Dashboard'
Tag to see the progress and status of your deployment.
Installation health-check
=========================
39. Perform system health-check
- Click the "Health Check" tab inside your Environment in the FUEL Web UI
- Check "Select All" and Click "Run Tests"
Note: Live-Migraition test will fail (Bug in ODL currently),
you can skip this test in the list if you choose to not see
the error message, simply uncheck it in the list
- Allow tests to run and investigate results where appropriate
40. Verify that the OpenDaylight GUI is accessible
TODO: Not available for WP1 Update at time of writing
Point your browser to the following URL:
http://{Controller-VIP}:8181/index.html> and login:
- Username: admin
- Password: admin
References
==========
OPNFV
-----
`OPNFV Home Page `_
`OPNFV Genesis project page `_
OpenStack
---------
`OpenStack Kilo Release artifacts `_
`OpenStack documentation `_
OpenDaylight
------------
`OpenDaylight artifacts `_
Fuel
----
`Fuel documentation `_
:Authors: Daniel Smith (Ericsson AB)
:Version: 2.0.0
**Documentation tracking**
Revision: _sha1_
Build date: _date