.. This work is licensed under a Creative Commons Attribution 4.0 International License. .. http://creativecommons.org/licenses/by/4.0 .. (c) Anuket and others =========================== Anuket Barometer User Guide =========================== Barometer collectd plugins description --------------------------------------- .. Describe the specific features and how it is realised in the scenario in a brief manner .. to ensure the user understand the context for the user guide instructions to follow. Collectd is a daemon which collects system performance statistics periodically and provides a variety of mechanisms to publish the collected metrics. It supports more than 90 different input and output plugins. Input plugins retrieve metrics and publish them to the collectd deamon, while output plugins publish the data they receive to an end point. collectd also has infrastructure to support thresholding and notification. Barometer has enabled the following collectd plugins: * *dpdkstat plugin*: A read plugin that retrieves stats from the DPDK extended NIC stats API. * *dpdkevents plugin*: A read plugin that retrieves DPDK link status and DPDK forwarding cores liveliness status (DPDK Keep Alive). * *dpdk_telemetry plugin*: A read plugin to collect dpdk interface stats and application or global stats from dpdk telemetry library. Both 'dpdkstat' and 'dpdk_telemetry' plugins provides dpdk NIC Stats, but only 'dpdk_telemetry' provides the DPDK Application stats. So in other words, 'dpdk_telemetry' is an advanced version of dpdkstat. This plugin don't deal with dpdk events. So not in related with 'dpdkevents' plugin. The mimimum dpdk version required to use this plugin is 19.08. .. note:: dpdpkstat and dpdk_telemetry should not be used together. Use dpdk_telemetry if your version of dpdk supports it (i.e. DPDK >= 19.08) and use dpdkstat otherwise. dpdkstat, dpdkevents and dpdk_telemetry plugins should only be used if your dpdk application doesn't already have more relevant metrics available(e.g.ovs_stats). * `gnocchi plugin`_: A write plugin that pushes the retrieved stats to Gnocchi. It's capable of pushing any stats read through collectd to Gnocchi, not just the DPDK stats. * `aodh plugin`_: A notification plugin that pushes events to Aodh, and creates/updates alarms appropriately. * *hugepages plugin*: A read plugin that retrieves the number of available and free hugepages on a platform as well as what is available in terms of hugepages per socket. * *Open vSwitch events Plugin*: A read plugin that retrieves events from OVS. * *Open vSwitch stats Plugin*: A read plugin that retrieves flow and interface stats from OVS. * *mcelog plugin*: A read plugin that uses mcelog client protocol to check for memory Machine Check Exceptions and sends the stats for reported exceptions. * *PMU plugin*: A read plugin that provides performance counters data on Intel CPUs using Linux perf interface. * *RDT plugin*: A read plugin that provides the last level cache utilization and memory bandwidth utilization. * *virt*: A read plugin that uses virtualization API *libvirt* to gather statistics about virtualized guests on a system directly from the hypervisor, without a need to install collectd instance on the guest. * *SNMP Agent*: A write plugin that will act as a AgentX subagent that receives and handles queries from SNMP master agent and returns the data collected by read plugins. The SNMP Agent plugin handles requests only for OIDs specified in configuration file. To handle SNMP queries the plugin gets data from collectd and translates requested values from collectd's internal format to SNMP format. Supports SNMP: get, getnext and walk requests. All the plugins above are available on the collectd main branch, except for the Gnocchi and Aodh plugins as they are Python-based plugins and only C plugins are accepted by the collectd community. The Gnocchi and Aodh plugins live in the OpenStack repositories. .. TODO: Update this to reflect merging of these PRs Other plugins existing as a pull request into collectd main: * *Legacy/IPMI*: A read plugin that reports platform thermals, voltages, fanspeed, current, flow, power etc. Also, the plugin monitors Intelligent Platform Management Interface (IPMI) System Event Log (SEL) and sends the appropriate notifications based on monitored SEL events. * *PCIe AER*: A read plugin that monitors PCIe standard and advanced errors and sends notifications about those errors. Third party application in Barometer repository: * *Open vSwitch PMD stats*: An aplication that retrieves PMD stats from OVS. It is run through exec plugin. **Plugins and application included in the Euphrates release:** Write Plugins: aodh plugin, SNMP agent plugin, gnocchi plugin. Read Plugins/application: Intel RDT plugin, virt plugin, Open vSwitch stats plugin, Open vSwitch PMD stats application. Collectd capabilities and usage ------------------------------------ .. Describe the specific capabilities and usage for feature. .. Provide enough information that a user will be able to operate the feature on a deployed scenario. The collectd plugins in Anuket are configured with reasonable defaults, but can be overridden. Building all Barometer upstreamed plugins from scratch ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ The plugins that have been merged to the collectd main branch can all be built and configured through the barometer repository. .. note:: * sudo permissions are required to install collectd. * These instructions are for Centos 7. To build all the upstream plugins, clone the barometer repo: .. code:: c $ git clone https://gerrit.opnfv.org/gerrit/barometer To install collectd as a service and install all it's dependencies: .. code:: bash $ cd barometer/systems && ./build_base_machine.sh This will install collectd as a service and the base install directory will be /opt/collectd. Sample configuration files can be found in '/opt/collectd/etc/collectd.conf.d' .. note:: If you don't want to use one of the Barometer plugins, simply remove the sample config file from '/opt/collectd/etc/collectd.conf.d' .. note:: If you plan on using the Exec plugin (for OVS_PMD_STATS or for executing scripts on notification generation), the plugin requires a non-root user to execute scripts. By default, `collectd_exec` user is used in the exec.conf provided in the sample configurations directory under src/collectd in the Barometer repo. These scripts *DO NOT* create this user. You need to create this user or modify the configuration in the sample configurations directory under src/collectd to use another existing non root user before running build_base_machine.sh. .. note:: If you are using any Open vSwitch plugins you need to run: .. code:: bash $ sudo ovs-vsctl set-manager ptcp:6640 After this, you should be able to start collectd as a service .. code:: bash $ sudo systemctl status collectd If you want to use granfana to display the metrics you collect, please see: `grafana guide`_ For more information on configuring and installing OpenStack plugins for collectd, check out the `collectd-openstack-plugins GSG`_. Below is the per plugin installation and configuration guide, if you only want to install some/particular plugins. DPDK plugins ^^^^^^^^^^^^^ Repo: https://github.com/collectd/collectd Branch: main Dependencies: DPDK (https://dpdk.org/) .. note:: DPDK statistics plugin requires DPDK version 16.04 or later. To build and install DPDK to /usr please see: https://github.com/collectd/collectd/blob/main/docs/BUILD.dpdkstat.md Building and installing collectd: .. code:: bash $ git clone https://github.com/collectd/collectd.git $ cd collectd $ ./build.sh $ ./configure --enable-syslog --enable-logfile --enable-debug $ make $ sudo make install .. note:: If DPDK was installed in a non standard location you will need to specify paths to the header files and libraries using *LIBDPDK_CPPFLAGS* and *LIBDPDK_LDFLAGS*. You will also need to add the DPDK library symbols to the shared library path using *ldconfig*. Note that this update to the shared library path is not persistant (i.e. it will not survive a reboot). Example of specifying custom paths to DPDK headers and libraries: .. code:: bash $ ./configure LIBDPDK_CPPFLAGS="path to DPDK header files" LIBDPDK_LDFLAGS="path to DPDK libraries" This will install collectd to default folder ``/opt/collectd``. The collectd configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``. To configure the dpdkstats plugin you need to modify the configuration file to include: .. code:: bash LoadPlugin dpdkstat Coremask "0xf" ProcessType "secondary" FilePrefix "rte" EnabledPortMask 0xffff PortName "interface1" PortName "interface2" To configure the dpdkevents plugin you need to modify the configuration file to include: .. code:: bash Interval 1 Coremask "0x1" MemoryChannels "4" FilePrefix "rte" SendEventsOnUpdate false EnabledPortMask 0xffff SendNotification true SendEventsOnUpdate false LCoreMask "0xf" KeepAliveShmName "/dpdk_keepalive_shm_name" SendNotification true .. note:: Currently, the DPDK library doesn’t support API to de-initialize the DPDK resources allocated on the initialization. It means, the collectd plugin will not be able to release the allocated DPDK resources (locks/memory/pci bindings etc.) correctly on collectd shutdown or reinitialize the DPDK library if primary DPDK process is restarted. The only way to release those resources is to terminate the process itself. For this reason, the plugin forks off a separate collectd process. This child process becomes a secondary DPDK process which can be run on specific CPU cores configured by user through collectd configuration file (“Coremask” EAL configuration option, the hexadecimal bitmask of the cores to run on). For more information on the plugin parameters, please see: https://github.com/collectd/collectd/blob/main/src/collectd.conf.pod .. note:: dpdkstat plugin initialization time depends on read interval. It requires 5 read cycles to set up internal buffers and states, during that time no statistics are submitted. Also, if plugin is running and the number of DPDK ports is increased, internal buffers are resized. That requires 3 read cycles and no port statistics are submitted during that time. The Address-Space Layout Randomization (ASLR) security feature in Linux should be disabled, in order for the same hugepage memory mappings to be present in all DPDK multi-process applications. To disable ASLR: .. code:: bash $ sudo echo 0 > /proc/sys/kernel/randomize_va_space To fully enable ASLR: .. code:: bash $ sudo echo 2 > /proc/sys/kernel/randomize_va_space .. warning:: Disabling Address-Space Layout Randomization (ASLR) may have security implications. It is recommended to be disabled only when absolutely necessary, and only when all implications of this change have been understood. For more information on multi-process support, please see: https://doc.dpdk.org/guides/prog_guide/multi_proc_support.html **DPDK stats plugin limitations:** 1. The DPDK primary process application should use the same version of DPDK that collectd DPDK plugin is using; 2. L2 statistics are only supported; 3. The plugin has been tested on Intel NIC’s only. **DPDK stats known issues:** * DPDK port visibility When network port controlled by Linux is bound to DPDK driver, the port will not be available in the OS. It affects the SNMP write plugin as those ports will not be present in standard IF-MIB. Thus, additional work is required to be done to support DPDK ports and statistics. **DPDK telemetry plugin** Please refer to https://wiki.anuket.io/display/HOME/DPDK+Telemetry+Plugin Hugepages Plugin ^^^^^^^^^^^^^^^^^ Repo: https://github.com/collectd/collectd Branch: main Dependencies: None, but assumes hugepages are configured. To configure some hugepages: .. code:: bash $ sudo mkdir -p /mnt/huge $ sudo mount -t hugetlbfs nodev /mnt/huge $ sudo bash -c "echo 14336 > /sys/devices/system/node/node0/hugepages/hugepages-2048kB/nr_hugepages" Building and installing collectd: .. code:: bash $ git clone https://github.com/collectd/collectd.git $ cd collectd $ ./build.sh $ ./configure --enable-syslog --enable-logfile --enable-hugepages --enable-debug $ make $ sudo make install This will install collectd to default folder ``/opt/collectd``. The collectd configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``. To configure the hugepages plugin you need to modify the configuration file to include: .. code:: bash LoadPlugin hugepages ReportPerNodeHP true ReportRootHP true ValuesPages true ValuesBytes false ValuesPercentage false For more information on the plugin parameters, please see: https://github.com/collectd/collectd/blob/main/src/collectd.conf.pod Intel PMU Plugin ^^^^^^^^^^^^^^^^ Repo: https://github.com/collectd/collectd Branch: main Dependencies: * PMU tools (jevents library) https://github.com/andikleen/pmu-tools To be suitable for use in collectd plugin shared library *libjevents* should be compiled as position-independent code. To do this add the following line to *pmu-tools/jevents/Makefile*: .. code:: bash CFLAGS += -fPIC Building and installing *jevents* library: .. code:: bash $ git clone https://github.com/andikleen/pmu-tools.git $ cd pmu-tools/jevents/ $ make $ sudo make install Download the Hardware Events that are relevant to your CPU, download the appropriate CPU event list json file: .. code:: bash $ wget https://raw.githubusercontent.com/andikleen/pmu-tools/main/event_download.py $ python event_download.py This will download the json files to the location: $HOME/.cache/pmu-events/. If you don't want to download these files to the aforementioned location, set the environment variable XDG_CACHE_HOME to the location you want the files downloaded to. Building and installing collectd: .. code:: bash $ git clone https://github.com/collectd/collectd.git $ cd collectd $ ./build.sh $ ./configure --enable-syslog --enable-logfile --with-libjevents=/usr/local --enable-debug $ make $ sudo make install This will install collectd to default folder ``/opt/collectd``. The collectd configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``. To configure the PMU plugin you need to modify the configuration file to include: .. code:: bash Interval 1 ReportHardwareCacheEvents true ReportKernelPMUEvents true ReportSoftwareEvents true Cores "" If you want to monitor Intel CPU specific CPU events, make sure to enable the additional two options shown below: .. code:: bash ReportHardwareCacheEvents true ReportKernelPMUEvents true ReportSoftwareEvents true EventList "$HOME/.cache/pmu-events/GenuineIntel-6-2D-core.json" HardwareEvents "L2_RQSTS.CODE_RD_HIT,L2_RQSTS.CODE_RD_MISS" "L2_RQSTS.ALL_CODE_RD" Cores "" .. note:: If you set XDG_CACHE_HOME to anything other than the variable above - you will need to modify the path for the EventList configuration. Use "Cores" option to monitor metrics only for configured cores. If an empty string is provided as value for this field default cores configuration is applied - that is all available cores are monitored separately. To limit monitoring to cores 0-7 set the option as shown below: .. code:: bash Cores "[0-7]" For more information on the plugin parameters, please see: https://github.com/collectd/collectd/blob/main/src/collectd.conf.pod .. note:: The plugin opens file descriptors whose quantity depends on number of monitored CPUs and number of monitored counters. Depending on configuration, it might be required to increase the limit on the number of open file descriptors allowed. This can be done using 'ulimit -n' command. If collectd is executed as a service 'LimitNOFILE=' directive should be defined in [Service] section of *collectd.service* file. Intel RDT Plugin ^^^^^^^^^^^^^^^^ Repo: https://github.com/collectd/collectd Branch: main Dependencies: * PQoS/Intel RDT library https://github.com/intel/intel-cmt-cat * msr kernel module Building and installing PQoS/Intel RDT library: .. code:: bash $ git clone https://github.com/intel/intel-cmt-cat $ cd intel-cmt-cat $ make $ make install PREFIX=/usr You will need to insert the msr kernel module: .. code:: bash $ modprobe msr Building and installing collectd: .. code:: bash $ git clone https://github.com/collectd/collectd.git $ cd collectd $ ./build.sh $ ./configure --enable-syslog --enable-logfile --with-libpqos=/usr/ --enable-debug $ make $ sudo make install This will install collectd to default folder ``/opt/collectd``. The collectd configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``. To configure the RDT plugin you need to modify the configuration file to include: .. code:: bash Interval 1 Cores "" For more information on the plugin parameters, please see: https://github.com/collectd/collectd/blob/main/src/collectd.conf.pod IPMI Plugin ^^^^^^^^^^^^ Repo: https://github.com/collectd/collectd Branch: feat_ipmi_events, feat_ipmi_analog Dependencies: OpenIPMI library (http://openipmi.sourceforge.net/) The IPMI plugin is already implemented in the latest collectd and sensors like temperature, voltage, fanspeed, current are already supported there. The list of supported IPMI sensors has been extended and sensors like flow, power are supported now. Also, a System Event Log (SEL) notification feature has been introduced. * The feat_ipmi_events branch includes new SEL feature support in collectd IPMI plugin. If this feature is enabled, the collectd IPMI plugin will dispatch notifications about new events in System Event Log. * The feat_ipmi_analog branch includes the support of extended IPMI sensors in collectd IPMI plugin. **Install dependencies** On Centos, install OpenIPMI library: .. code:: bash $ sudo yum install OpenIPMI ipmitool Anyway, it's recommended to use the latest version of the OpenIPMI library as it includes fixes of known issues which aren't included in standard OpenIPMI library package. The latest version of the library can be found at https://sourceforge.net/p/openipmi/code/ci/master/tree/. Steps to install the library from sources are described below. Remove old version of OpenIPMI library: .. code:: bash $ sudo yum remove OpenIPMI ipmitool Build and install OpenIPMI library: .. code:: bash $ git clone https://git.code.sf.net/p/openipmi/code openipmi-code $ cd openipmi-code $ autoreconf --install $ ./configure --prefix=/usr $ make $ sudo make install Add the directory containing ``OpenIPMI*.pc`` files to the ``PKG_CONFIG_PATH`` environment variable: .. code:: bash export PKG_CONFIG_PATH=/usr/lib/pkgconfig Enable IPMI support in the kernel: .. code:: bash $ sudo modprobe ipmi_devintf $ sudo modprobe ipmi_si .. note:: If HW supports IPMI, the ``/dev/ipmi0`` character device will be created. Clone and install the collectd IPMI plugin: .. code:: bash $ git clone https://github.com/collectd/collectd $ cd collectd $ ./build.sh $ ./configure --enable-syslog --enable-logfile --enable-debug $ make $ sudo make install This will install collectd to default folder ``/opt/collectd``. The collectd configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``. To configure the IPMI plugin you need to modify the file to include: .. code:: bash LoadPlugin ipmi SELEnabled true # only feat_ipmi_events branch supports this .. note:: By default, IPMI plugin will read all available analog sensor values, dispatch the values to collectd and send SEL notifications. For more information on the IPMI plugin parameters and SEL feature configuration, please see: https://github.com/collectd/collectd/blob/main/src/collectd.conf.pod Extended analog sensors support doesn't require additional configuration. The usual collectd IPMI documentation can be used: - https://collectd.org/wiki/index.php/Plugin:IPMI - https://collectd.org/documentation/manpages/collectd.conf.5.shtml#plugin_ipmi IPMI documentation: - https://www.kernel.org/doc/Documentation/IPMI.txt - https://www.intel.com/content/www/us/en/products/docs/servers/ipmi/ipmi-second-gen-interface-spec-v2-rev1-1.html Mcelog Plugin ^^^^^^^^^^^^^^ Repo: https://github.com/collectd/collectd Branch: main Dependencies: mcelog Start by installing mcelog. .. note:: The kernel has to have CONFIG_X86_MCE enabled. For 32bit kernels you need atleast a 2.6,30 kernel. On Centos: .. code:: bash $ sudo yum install mcelog Or build from source .. code:: bash $ git clone https://git.kernel.org/pub/scm/utils/cpu/mce/mcelog.git $ cd mcelog $ make ... become root ... $ make install $ cp mcelog.service /etc/systemd/system/ $ systemctl enable mcelog.service $ systemctl start mcelog.service Verify you got a /dev/mcelog. You can verify the daemon is running completely by running: .. code:: bash $ mcelog --client This should query the information in the running daemon. If it prints nothing that is fine (no errors logged yet). More info @ http://www.mcelog.org/installation.html Modify the mcelog configuration file "/etc/mcelog/mcelog.conf" to include or enable: .. code:: bash socket-path = /var/run/mcelog-client [dimm] dimm-tracking-enabled = yes dmi-prepopulate = yes uc-error-threshold = 1 / 24h ce-error-threshold = 10 / 24h [socket] socket-tracking-enabled = yes mem-uc-error-threshold = 100 / 24h mem-ce-error-threshold = 100 / 24h mem-ce-error-log = yes [page] memory-ce-threshold = 10 / 24h memory-ce-log = yes memory-ce-action = soft [trigger] children-max = 2 directory = /etc/mcelog Clone and install the collectd mcelog plugin: .. code:: bash $ git clone https://github.com/collectd/collectd $ cd collectd $ ./build.sh $ ./configure --enable-syslog --enable-logfile --enable-debug $ make $ sudo make install This will install collectd to default folder ``/opt/collectd``. The collectd configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``. To configure the mcelog plugin you need to modify the configuration file to include: .. code:: bash Interval 1 McelogClientSocket "/var/run/mcelog-client" PersistentNotification false #McelogLogfile "/var/log/mcelog" For more information on the plugin parameters, please see: https://github.com/collectd/collectd/blob/main/src/collectd.conf.pod Simulating a Machine Check Exception can be done in one of 3 ways: * Running $make test in the mcelog cloned directory - mcelog test suite * using mce-inject * using mce-test **mcelog test suite:** It is always a good idea to test an error handling mechanism before it is really needed. mcelog includes a test suite. The test suite relies on mce-inject which needs to be installed and in $PATH. You also need the mce-inject kernel module configured (with CONFIG_X86_MCE_INJECT=y), compiled, installed and loaded: .. code:: bash $ modprobe mce-inject Then you can run the mcelog test suite with .. code:: bash $ make test This will inject different classes of errors and check that the mcelog triggers runs. There will be some kernel messages about page offlining attempts. The test will also lose a few pages of memory in your system (not significant). .. note:: This test will kill any running mcelog, which needs to be restarted manually afterwards. **mce-inject:** A utility to inject corrected, uncorrected and fatal machine check exceptions .. code:: bash $ git clone https://git.kernel.org/pub/scm/utils/cpu/mce/mce-inject.git $ cd mce-inject $ make $ modprobe mce-inject Modify the test/corrected script to include the following: .. code:: bash CPU 0 BANK 0 STATUS 0xcc00008000010090 ADDR 0x0010FFFFFFF Inject the error: .. code:: bash $ ./mce-inject < test/corrected .. note:: The uncorrected and fatal scripts under test will cause a platform reset. Only the fatal script generates the memory errors**. In order to quickly emulate uncorrected memory errors and avoid host reboot following test errors from mce-test suite can be injected: .. code:: bash $ mce-inject mce-test/cases/coverage/soft-inj/recoverable_ucr/data/srao_mem_scrub **mce-test:** In addition a more in-depth test of the Linux kernel machine check facilities can be done with the mce-test test suite. mce-test supports testing uncorrected error handling, real error injection, handling of different soft offlining cases, and other tests. **Corrected memory error injection:** To inject corrected memory errors: * Remove sb_edac and edac_core kernel modules: rmmod sb_edac rmmod edac_core * Insert einj module: modprobe einj param_extension=1 * Inject an error by specifying details (last command should be repeated at least two times): .. code:: bash $ APEI_IF=/sys/kernel/debug/apei/einj $ echo 0x8 > $APEI_IF/error_type $ echo 0x01f5591000 > $APEI_IF/param1 $ echo 0xfffffffffffff000 > $APEI_IF/param2 $ echo 1 > $APEI_IF/notrigger $ echo 1 > $APEI_IF/error_inject * Check the MCE statistic: mcelog --client. Check the mcelog log for injected error details: less /var/log/mcelog. Open vSwitch Plugins ^^^^^^^^^^^^^^^^^^^^^ OvS Plugins Repo: https://github.com/collectd/collectd OvS Plugins Branch: main OvS Events MIBs: The SNMP OVS interface link status is provided by standard IF-MIB (http://www.net-snmp.org/docs/mibs/IF-MIB.txt) Dependencies: Open vSwitch, Yet Another JSON Library (https://github.com/lloyd/yajl) On Centos, install the dependencies and Open vSwitch: .. code:: bash $ sudo yum install yajl-devel Steps to install Open vSwtich can be found at https://docs.openvswitch.org/en/latest/intro/install/fedora/ Start the Open vSwitch service: .. code:: bash $ sudo service openvswitch-switch start Configure the ovsdb-server manager: .. code:: bash $ sudo ovs-vsctl set-manager ptcp:6640 Clone and install the collectd ovs plugin: .. code:: bash $ git clone $REPO $ cd collectd $ git checkout main $ ./build.sh $ ./configure --enable-syslog --enable-logfile --enable-debug $ make $ sudo make install This will install collectd to default folder ``/opt/collectd``. The collectd configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``. To configure the OVS events plugin you need to modify the configuration file to include: .. code:: bash Interval 1 Port "6640" Address "127.0.0.1" Socket "/var/run/openvswitch/db.sock" Interfaces "br0" "veth0" SendNotification true To configure the OVS stats plugin you need to modify the configuration file to include: .. code:: bash Interval 1 Port "6640" Address "127.0.0.1" Socket "/var/run/openvswitch/db.sock" Bridges "br0" For more information on the plugin parameters, please see: https://github.com/collectd/collectd/blob/main/src/collectd.conf.pod OVS PMD stats ^^^^^^^^^^^^^^ Repo: https://gerrit.opnfv.org/gerrit/barometer Prequistes: 1. Open vSwitch dependencies are installed. 2. Open vSwitch service is running. 3. Ovsdb-server manager is configured. You can refer `Open vSwitch Plugins`_ section above for each one of them. OVS PMD stats application is run through the exec plugin. To configure the OVS PMD stats application you need to modify the exec plugin configuration to include: .. code:: bash Interval 1 Exec "user:group" "" .. note:: Exec plugin configuration has to be changed to use appropriate user before starting collectd service. ovs_pmd_stat.sh calls the script for OVS PMD stats application with its argument: .. code:: bash sudo python /usr/local/src/ovs_pmd_stats.py" "--socket-pid-file" "/var/run/openvswitch/ovs-vswitchd.pid" SNMP Agent Plugin ^^^^^^^^^^^^^^^^^ Repo: https://github.com/collectd/collectd Branch: main Dependencies: NET-SNMP library Start by installing net-snmp and dependencies. On Centos 7: .. code:: bash $ sudo yum install net-snmp net-snmp-libs net-snmp-utils net-snmp-devel $ sudo systemctl start snmpd.service go to the `snmp configuration`_ steps. From source: Clone and build net-snmp: .. code:: bash $ git clone https://github.com/haad/net-snmp.git $ cd net-snmp $ ./configure --with-persistent-directory="/var/net-snmp" --with-systemd --enable-shared --prefix=/usr $ make Become root .. code:: bash $ make install Copy default configuration to persistent folder: .. code:: bash $ cp EXAMPLE.conf /usr/share/snmp/snmpd.conf Set library path and default MIB configuration: .. code:: bash $ cd ~/ $ echo export LD_LIBRARY_PATH=/usr/lib >> .bashrc $ net-snmp-config --default-mibdirs $ net-snmp-config --snmpconfpath Configure snmpd as a service: .. code:: bash $ cd net-snmp $ cp ./dist/snmpd.service /etc/systemd/system/ $ systemctl enable snmpd.service $ systemctl start snmpd.service .. _`snmp configuration`: Add the following line to snmpd.conf configuration file ``/etc/snmp/snmpd.conf`` to make all OID tree visible for SNMP clients: .. code:: bash view systemview included .1 To verify that SNMP is working you can get IF-MIB table using SNMP client to view the list of Linux interfaces: .. code:: bash $ snmpwalk -v 2c -c public localhost IF-MIB::interfaces Get the default MIB location: .. code:: bash $ net-snmp-config --default-mibdirs /opt/stack/.snmp/mibs:/usr/share/snmp/mibs Install Intel specific MIBs (if needed) into location received by ``net-snmp-config`` command (e.g. ``/usr/share/snmp/mibs``). .. code:: bash $ git clone https://gerrit.opnfv.org/gerrit/barometer.git $ sudo cp -f barometer/mibs/*.txt /usr/share/snmp/mibs/ $ sudo systemctl restart snmpd.service Clone and install the collectd snmp_agent plugin: .. code:: bash $ cd ~ $ git clone https://github.com/collectd/collectd $ cd collectd $ ./build.sh $ ./configure --enable-syslog --enable-logfile --enable-debug --enable-snmp --with-libnetsnmp $ make $ sudo make install This will install collectd to default folder ``/opt/collectd``. The collectd configuration file (``collectd.conf``) can be found at ``/opt/collectd/etc``. **SNMP Agent plugin is a generic plugin and cannot work without configuration**. To configure the snmp_agent plugin you need to modify the configuration file to include OIDs mapped to collectd types. The following example maps scalar memAvailReal OID to value represented as free memory type of memory plugin: .. code:: bash LoadPlugin snmp_agent Plugin "memory" Type "memory" TypeInstance "free" OIDs "1.3.6.1.4.1.2021.4.6.0" The ``snmpwalk`` command can be used to validate the collectd configuration: .. code:: bash $ snmpwalk -v 2c -c public localhost 1.3.6.1.4.1.2021.4.6.0 UCD-SNMP-MIB::memAvailReal.0 = INTEGER: 135237632 kB **Limitations** * Object instance with Counter64 type is not supported in SNMPv1. When GetNext request is received, Counter64 type objects will be skipped. When Get request is received for Counter64 type object, the error will be returned. * Interfaces that are not visible to Linux like DPDK interfaces cannot be retreived using standard IF-MIB tables. For more information on the plugin parameters, please see: https://github.com/collectd/collectd/blob/main/src/collectd.conf.pod For more details on AgentX subagent, please see: http://www.net-snmp.org/tutorial/tutorial-5/toolkit/demon/ .. _virt-plugin: virt plugin ^^^^^^^^^^^^ Repo: https://github.com/collectd/collectd Branch: main Dependencies: libvirt (https://libvirt.org/), libxml2 On Centos, install the dependencies: .. code:: bash $ sudo yum install libxml2-devel libpciaccess-devel yajl-devel device-mapper-devel Install libvirt: .. note:: libvirt version in package manager might be quite old and offer only limited functionality. Hence, building and installing libvirt from sources is recommended. Detailed instructions can bet found at: https://libvirt.org/compiling.html .. code:: bash $ sudo yum install libvirt-devel Certain metrics provided by the plugin have a requirement on a minimal version of the libvirt API. *File system information* statistics require a *Guest Agent (GA)* to be installed and configured in a VM. User must make sure that installed GA version supports retrieving file system information. Number of *Performance monitoring events* metrics depends on running libvirt daemon version. .. note:: Please keep in mind that RDT metrics (part of *Performance monitoring events*) have to be supported by hardware. For more details on hardware support, please see: https://github.com/intel/intel-cmt-cat Additionally perf metrics **cannot** be collected if *Intel RDT* plugin is enabled. libvirt version can be checked with following commands: .. code:: bash $ virsh --version $ libvirtd --version .. table:: Extended statistics requirements +-------------------------------+--------------------------+-------------+ | Statistic | Min. libvirt API version | Requires GA | +===============================+==========================+=============+ | Domain reason | 0.9.2 | No | +-------------------------------+--------------------------+-------------+ | Disk errors | 0.9.10 | No | +-------------------------------+--------------------------+-------------+ | Job statistics | 1.2.9 | No | +-------------------------------+--------------------------+-------------+ | File system information | 1.2.11 | Yes | +-------------------------------+--------------------------+-------------+ | Performance monitoring events | 1.3.3 | No | +-------------------------------+--------------------------+-------------+ Start libvirt daemon: .. code:: bash $ systemctl start libvirtd Create domain (VM) XML configuration file. For more information on domain XML format and examples, please see: https://libvirt.org/formatdomain.html .. note:: Installing additional hypervisor dependencies might be required before deploying virtual machine. Create domain, based on created XML file: .. code:: bash $ virsh define DOMAIN_CFG_FILE.xml Start domain: .. code:: bash $ virsh start DOMAIN_NAME Check if domain is running: .. code:: bash $ virsh list Check list of available *Performance monitoring events* and their settings: .. code:: bash $ virsh perf DOMAIN_NAME Enable or disable *Performance monitoring events* for domain: .. code:: bash $ virsh perf DOMAIN_NAME [--enable | --disable] EVENT_NAME --live Clone and install the collectd virt plugin: .. code:: bash $ git clone $REPO $ cd collectd $ ./build.sh $ ./configure --enable-syslog --enable-logfile --enable-debug $ make $ sudo make install Where ``$REPO`` is equal to information provided above. This will install collectd to ``/opt/collectd``. The collectd configuration file ``collectd.conf`` can be found at ``/opt/collectd/etc``. To load the virt plugin user needs to modify the configuration file to include: .. code:: bash LoadPlugin virt Additionally, user can specify plugin configuration parameters in this file, such as connection URL, domain name and much more. By default extended virt plugin statistics are disabled. They can be enabled with ``ExtraStats`` option. .. code:: bash RefreshInterval 60 ExtraStats "cpu_util disk disk_err domain_state fs_info job_stats_background pcpu perf vcpupin" For more information on the plugin parameters, please see: https://github.com/collectd/collectd/blob/main/src/collectd.conf.pod .. _install-collectd-as-a-service: Installing collectd as a service ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ Collectd service scripts are available in the collectd/contrib directory. To install collectd as a service: .. code:: bash $ sudo cp contrib/systemd.collectd.service /etc/systemd/system/ $ cd /etc/systemd/system/ $ sudo mv systemd.collectd.service collectd.service $ sudo chmod +x collectd.service Modify collectd.service .. code:: bash [Service] ExecStart=/opt/collectd/sbin/collectd EnvironmentFile=-/opt/collectd/etc/ EnvironmentFile=-/opt/collectd/etc/ CapabilityBoundingSet=CAP_SETUID CAP_SETGID Reload .. code:: bash $ sudo systemctl daemon-reload $ sudo systemctl start collectd.service $ sudo systemctl status collectd.service should show success Additional useful plugins ^^^^^^^^^^^^^^^^^^^^^^^^^^ **Exec Plugin** : Can be used to show you when notifications are being generated by calling a bash script that dumps notifications to file. (handy for debug). Modify /opt/collectd/etc/collectd.conf: .. code:: bash LoadPlugin exec # Exec "user:group" "/path/to/exec" NotificationExec "user" "/barometer/src/collectd/collectd_sample_configs/write_notification.sh" write_notification.sh (just writes the notification passed from exec through STDIN to a file (/tmp/notifications)): .. code:: bash #!/bin/bash rm -f /tmp/notifications while read x y do echo $x$y >> /tmp/notifications done output to /tmp/notifications should look like: .. code:: bash Severity:WARNING Time:1479991318.806 Host:localhost Plugin:ovs_events PluginInstance:br-ex Type:gauge TypeInstance:link_status uuid:f2aafeec-fa98-4e76-aec5-18ae9fc74589 linkstate of "br-ex" interface has been changed to "DOWN" * **logfile plugin**: Can be used to log collectd activity. Modify /opt/collectd/etc/collectd.conf to include: .. code:: bash LoadPlugin logfile LogLevel info File "/var/log/collectd.log" Timestamp true PrintSeverity false Monitoring Interfaces and Openstack Support ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^ .. Figure:: monitoring_interfaces.png Monitoring Interfaces and Openstack Support The figure above shows the DPDK L2 forwarding application running on a compute node, sending and receiving traffic. Collectd is also running on this compute node retrieving the stats periodically from DPDK through the dpdkstat plugin and publishing the retrieved stats to OpenStack through the collectd-openstack-plugins. To see this demo in action please checkout: `Barometer OPNFV Summit demo`_ For more information on configuring and installing OpenStack plugins for collectd, check out the `collectd-openstack-plugins GSG`_. Security ^^^^^^^^^ * AAA – on top of collectd there secure agents like SNMP V3, Openstack agents etc. with their own AAA methods. * Collectd runs as a daemon with root permissions. * The `Exec plugin`_ allows the execution of external programs but counters the security concerns by: * Ensuring that only one instance of the program is executed by collectd at any time * Forcing the plugin to check that custom programs are never executed with superuser privileges. * Protection of Data in flight: * It's recommend to use a minimum version of 4.7 of the Network plugin which provides the possibility to cryptographically sign or encrypt the network traffic. * Write Redis plugin or the Write MongoDB plugin are recommended to store the data. * For more information, please see: https://collectd.org/wiki/index.php?title=Networking_introduction * Known vulnerabilities include: * https://www.cvedetails.com/vulnerability-list/vendor_id-11242/Collectd.html * `CVE-2017-7401`_ fixed https://github.com/collectd/collectd/issues/2174 in Version 5.7.2. * `CVE-2016-6254`_ fixed https://mailman.verplant.org/pipermail/collectd/2016-July/006838.html in Version 5.4.3. * `CVE-2010-4336`_ fixed https://mailman.verplant.org/pipermail/collectd/2010-November/004277.html in Version 4.10.2. * https://www.cvedetails.com/product/20310/Collectd-Collectd.html?vendor_id=11242 * It's recommended to only use collectd plugins from signed packages. References ^^^^^^^^^^^ .. [1] https://collectd.org/wiki/index.php/Naming_schema .. [2] https://github.com/collectd/collectd/blob/main/src/daemon/plugin.h .. [3] https://collectd.org/wiki/index.php/Value_list_t .. [4] https://collectd.org/wiki/index.php/Data_set .. [5] https://collectd.org/documentation/manpages/types.db.5.shtml .. [6] https://collectd.org/wiki/index.php/Data_source .. [7] https://collectd.org/wiki/index.php/Meta_Data_Interface .. _Barometer OPNFV Summit demo: https://prezi.com/kjv6o8ixs6se/software-fastpath-service-quality-metrics-demo/ .. _gnocchi plugin: https://github.com/openstack/collectd-openstack-plugins/tree/stable/ocata/ .. _aodh plugin: https://github.com/openstack/collectd-openstack-plugins/tree/stable/ocata/ .. _collectd-openstack-plugins GSG: https://opendev.org/x/collectd-openstack-plugins/src/branch/master/doc/source/GSG.rst .. _grafana guide: https://wiki.anuket.io/display/HOME/Installing+and+configuring+InfluxDB+and+Grafana+to+display+metrics+with+collectd .. _CVE-2017-7401: https://www.cvedetails.com/cve/CVE-2017-7401/ .. _CVE-2016-6254: https://www.cvedetails.com/cve/CVE-2016-6254/ .. _CVE-2010-4336: https://www.cvedetails.com/cve/CVE-2010-4336/ .. _Exec plugin: https://collectd.org/wiki/index.php/Plugin:Exec