:::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: : Copyright (c) 2017 Enea AB and others. : : All rights reserved. This program and the accompanying materials : are made available under the terms of the Apache License, Version 2.0 : which accompanies this distribution, and is available at : http://www.apache.org/licenses/LICENSE-2.0 :::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::::: From: Alexandru Avadanii Date: Tue, 19 Sep 2017 16:51:21 +0200 Subject: [PATCH] pod_config.yml: Use arm-pod5 specific config Signed-off-by: Alexandru Avadanii --- .../all-mcp-ocata-common/opnfv/pod_config.yml | 125 +++++++++++---------- 1 file changed, 63 insertions(+), 62 deletions(-) diff --git a/mcp/reclass/classes/cluster/all-mcp-ocata-common/opnfv/pod_config.yml b/mcp/reclass/classes/cluster/all-mcp-ocata-common/opnfv/pod_config.yml index 90c3c85..68b048f 100644 --- a/mcp/reclass/classes/cluster/all-mcp-ocata-common/opnfv/pod_config.yml +++ b/mcp/reclass/classes/cluster/all-mcp-ocata-common/opnfv/pod_config.yml @@ -2,92 +2,93 @@ parameters: _param: # infra service addresses - opnfv_infra_config_address: 10.167.4.100 - opnfv_infra_config_deploy_address: 10.20.0.2 - opnfv_infra_maas_node01_address: 10.167.4.3 + opnfv_infra_config_address: 172.16.10.100 + opnfv_infra_maas_node01_address: 172.16.10.3 opnfv_infra_maas_node01_deploy_address: 192.168.11.3 - opnfv_infra_compute_node01_address: 10.167.4.141 - opnfv_infra_compute_node02_address: 10.167.4.142 - opnfv_infra_compute_node03_address: 10.167.4.143 - opnfv_infra_kvm_address: 10.167.4.140 - opnfv_infra_kvm_node01_address: 10.167.4.141 - opnfv_infra_kvm_node02_address: 10.167.4.142 - opnfv_infra_kvm_node03_address: 10.167.4.143 + opnfv_infra_compute_node01_address: 172.16.10.141 + opnfv_infra_compute_node02_address: 172.16.10.142 + opnfv_infra_compute_node03_address: 172.16.10.143 + opnfv_infra_kvm_address: 172.16.10.140 + opnfv_infra_kvm_node01_address: 172.16.10.141 + opnfv_infra_kvm_node02_address: 172.16.10.142 + opnfv_infra_kvm_node03_address: 172.16.10.143 - opnfv_openstack_gateway_node01_address: 10.167.4.124 - opnfv_openstack_gateway_node02_address: 10.167.4.125 - opnfv_openstack_gateway_node03_address: 10.167.4.126 + opnfv_openstack_gateway_node01_address: 172.16.10.124 + opnfv_openstack_gateway_node02_address: 172.16.10.125 + opnfv_openstack_gateway_node03_address: 172.16.10.126 opnfv_openstack_gateway_node01_tenant_address: 10.1.0.6 opnfv_openstack_gateway_node02_tenant_address: 10.1.0.7 opnfv_openstack_gateway_node03_tenant_address: 10.1.0.9 - opnfv_openstack_proxy_address: 10.167.4.80 - opnfv_openstack_proxy_node01_address: 10.167.4.81 - opnfv_openstack_proxy_node02_address: 10.167.4.82 - opnfv_openstack_control_address: 10.167.4.10 - opnfv_openstack_control_node01_address: 10.167.4.11 - opnfv_openstack_control_node02_address: 10.167.4.12 - opnfv_openstack_control_node03_address: 10.167.4.13 - opnfv_openstack_database_address: 10.167.4.50 - opnfv_openstack_database_node01_address: 10.167.4.51 - opnfv_openstack_database_node02_address: 10.167.4.52 - opnfv_openstack_database_node03_address: 10.167.4.53 - opnfv_openstack_message_queue_address: 10.167.4.40 - opnfv_openstack_message_queue_node01_address: 10.167.4.41 - opnfv_openstack_message_queue_node02_address: 10.167.4.42 - opnfv_openstack_message_queue_node03_address: 10.167.4.43 - opnfv_openstack_telemetry_address: 10.167.4.75 - opnfv_openstack_telemetry_node01_address: 10.167.4.76 - opnfv_openstack_telemetry_node02_address: 10.167.4.77 - opnfv_openstack_telemetry_node03_address: 10.167.4.78 - opnfv_openstack_compute_node01_single_address: 10.167.4.101 - opnfv_openstack_compute_node02_single_address: 10.167.4.102 - opnfv_openstack_compute_node03_single_address: 10.167.4.103 - opnfv_openstack_compute_node01_control_address: 10.167.4.101 - opnfv_openstack_compute_node02_control_address: 10.167.4.102 - opnfv_openstack_compute_node03_control_address: 10.167.4.103 + opnfv_openstack_proxy_address: 172.16.10.80 + opnfv_openstack_proxy_node01_address: 172.16.10.81 + opnfv_openstack_proxy_node02_address: 172.16.10.82 + opnfv_openstack_control_address: 172.16.10.10 + opnfv_openstack_control_node01_address: 172.16.10.11 + opnfv_openstack_control_node02_address: 172.16.10.12 + opnfv_openstack_control_node03_address: 172.16.10.13 + opnfv_openstack_database_address: 172.16.10.50 + opnfv_openstack_database_node01_address: 172.16.10.51 + opnfv_openstack_database_node02_address: 172.16.10.52 + opnfv_openstack_database_node03_address: 172.16.10.53 + opnfv_openstack_message_queue_address: 172.16.10.40 + opnfv_openstack_message_queue_node01_address: 172.16.10.41 + opnfv_openstack_message_queue_node02_address: 172.16.10.42 + opnfv_openstack_message_queue_node03_address: 172.16.10.43 + opnfv_openstack_telemetry_address: 172.16.10.75 + opnfv_openstack_telemetry_node01_address: 172.16.10.76 + opnfv_openstack_telemetry_node02_address: 172.16.10.77 + opnfv_openstack_telemetry_node03_address: 172.16.10.78 + opnfv_openstack_compute_node01_single_address: 172.16.10.101 + opnfv_openstack_compute_node02_single_address: 172.16.10.102 + opnfv_openstack_compute_node03_single_address: 172.16.10.103 + opnfv_openstack_compute_node01_control_address: 172.16.10.101 + opnfv_openstack_compute_node02_control_address: 172.16.10.102 + opnfv_openstack_compute_node03_control_address: 172.16.10.103 opnfv_openstack_compute_node01_tenant_address: 10.1.0.101 opnfv_openstack_compute_node02_tenant_address: 10.1.0.102 opnfv_openstack_compute_node03_tenant_address: 10.1.0.103 - opnfv_openstack_compute_node01_external_address: 172.30.10.2 - opnfv_openstack_compute_node02_external_address: 172.30.10.3 + opnfv_openstack_compute_node01_external_address: 10.0.8.101 + opnfv_openstack_compute_node02_external_address: 10.0.8.102 + # opendaylight options + #opnfv_opendaylight_server_node01_single_address: 172.16.10.111 opnfv_name_servers: ['8.8.8.8', '8.8.4.4'] opnfv_dns_server01: '8.8.8.8' - opnfv_net_mgmt_vlan: 300 - opnfv_net_tenant_vlan: 302 + opnfv_net_mgmt_vlan: 2183 + opnfv_net_tenant_vlan: 2185 - opnfv_maas_node01_architecture: amd64/generic - opnfv_maas_node01_power_address: 172.30.8.75 + opnfv_maas_node01_architecture: 'arm64/generic' + opnfv_maas_node01_power_address: 10.0.8.3 opnfv_maas_node01_power_type: ipmi opnfv_maas_node01_power_user: admin - opnfv_maas_node01_power_password: octopus - opnfv_maas_node01_interface_mac: "00:25:b5:a0:00:2a" + opnfv_maas_node01_power_password: admin + opnfv_maas_node01_interface_mac: 'e0:ff:f7:00:08:ae' - opnfv_maas_node02_architecture: amd64/generic - opnfv_maas_node02_power_address: 172.30.8.65 + opnfv_maas_node02_architecture: 'arm64/generic' + opnfv_maas_node02_power_address: 10.0.8.4 opnfv_maas_node02_power_type: ipmi opnfv_maas_node02_power_user: admin - opnfv_maas_node02_power_password: octopus - opnfv_maas_node02_interface_mac: "00:25:b5:a0:00:3a" + opnfv_maas_node02_power_password: admin + opnfv_maas_node02_interface_mac: 'e0:ff:f7:00:08:b1' - opnfv_maas_node03_architecture: amd64/generic - opnfv_maas_node03_power_address: 172.30.8.74 + opnfv_maas_node03_architecture: 'arm64/generic' + opnfv_maas_node03_power_address: 10.0.8.5 opnfv_maas_node03_power_type: ipmi opnfv_maas_node03_power_user: admin - opnfv_maas_node03_power_password: octopus - opnfv_maas_node03_interface_mac: "00:25:b5:a0:00:4a" + opnfv_maas_node03_power_password: admin + opnfv_maas_node03_interface_mac: 'e0:ff:f7:00:08:bd' - opnfv_maas_node04_architecture: amd64/generic - opnfv_maas_node04_power_address: 172.30.8.73 + opnfv_maas_node04_architecture: 'arm64/generic' + opnfv_maas_node04_power_address: 10.0.8.6 opnfv_maas_node04_power_type: ipmi opnfv_maas_node04_power_user: admin - opnfv_maas_node04_power_password: octopus - opnfv_maas_node04_interface_mac: "00:25:b5:a0:00:5a" + opnfv_maas_node04_power_password: admin + opnfv_maas_node04_interface_mac: 'e0:ff:f7:00:08:c6' - opnfv_maas_node05_architecture: amd64/generic - opnfv_maas_node05_power_address: 172.30.8.72 + opnfv_maas_node05_architecture: 'arm64/generic' + opnfv_maas_node05_power_address: 10.0.8.7 opnfv_maas_node05_power_type: ipmi opnfv_maas_node05_power_user: admin - opnfv_maas_node05_power_password: octopus - opnfv_maas_node05_interface_mac: "00:25:b5:a0:00:6a" + opnfv_maas_node05_power_password: admin + opnfv_maas_node05_interface_mac: 'e0:ff:f7:00:08:cf'